From version < 94.6 >
edited by Xiaoling
on 2022/06/10 10:45
To version < 93.9 >
edited by Xiaoling
on 2022/06/10 10:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -913,10 +913,10 @@
913 913  
914 914  
915 915  
916 -= 4.  Configure LLDS12 via AT Command or LoRaWAN Downlink =
916 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
917 917  
918 918  (((
919 -Use can configure LLDS12 via AT Command or LoRaWAN Downlink.
919 +Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
920 920  )))
921 921  
922 922  * (((
... ... @@ -927,8 +927,6 @@
927 927  )))
928 928  
929 929  (((
930 -
931 -
932 932  There are two kinds of commands to configure LSPH01, they are:
933 933  )))
934 934  
... ... @@ -1119,12 +1119,12 @@
1119 1119  
1120 1120  
1121 1121  
1122 -= 5.  Battery & How to replace =
1120 += 4. Battery & How to replace =
1123 1123  
1124 -== 5.1  Battery Type ==
1122 +== 4.1 Battery Type ==
1125 1125  
1126 1126  (((
1127 -LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1125 +LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1128 1128  )))
1129 1129  
1130 1130  (((
... ... @@ -1134,13 +1134,13 @@
1134 1134  [[image:1654593587246-335.png]]
1135 1135  
1136 1136  
1137 -Minimum Working Voltage for the LLDS12:
1135 +Minimum Working Voltage for the LSPH01:
1138 1138  
1139 -LLDS12:  2.45v ~~ 3.6v
1137 +LSPH01:  2.45v ~~ 3.6v
1140 1140  
1141 1141  
1142 1142  
1143 -== 5.2  Replace Battery ==
1141 +== 4.2 Replace Battery ==
1144 1144  
1145 1145  (((
1146 1146  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  
1154 1154  
1155 -== 5.3  Power Consumption Analyze ==
1153 +== 4.3 Power Consumption Analyze ==
1156 1156  
1157 1157  (((
1158 1158  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -1195,7 +1195,7 @@
1195 1195  
1196 1196  
1197 1197  
1198 -=== 5.3.1  ​Battery Note ===
1196 +=== 4.3.1 ​Battery Note ===
1199 1199  
1200 1200  (((
1201 1201  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
... ... @@ -1203,23 +1203,23 @@
1203 1203  
1204 1204  
1205 1205  
1206 -=== ​5.3.2  Replace the battery ===
1204 +=== ​4.3.2 Replace the battery ===
1207 1207  
1208 1208  (((
1209 -You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1207 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1210 1210  )))
1211 1211  
1212 1212  (((
1213 -The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1211 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1214 1214  )))
1215 1215  
1216 1216  
1217 1217  
1218 -= 6.  Use AT Command =
1216 += 5. Use AT Command =
1219 1219  
1220 -== 6.1  Access AT Commands ==
1218 +== 5.1 Access AT Commands ==
1221 1221  
1222 -LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below.
1220 +LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1223 1223  
1224 1224  [[image:1654593668970-604.png]]
1225 1225  
... ... @@ -1242,9 +1242,9 @@
1242 1242  Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1243 1243  
1244 1244  
1245 -= 7.  FAQ =
1243 += 6.  FAQ =
1246 1246  
1247 -== 7.1  How to change the LoRa Frequency Bands/Region ==
1245 +== 6.1  How to change the LoRa Frequency Bands/Region ==
1248 1248  
1249 1249  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1250 1250  When downloading the images, choose the required image file for download. ​
... ... @@ -1254,7 +1254,6 @@
1254 1254  
1255 1255  == 8.1  AT Commands input doesn’t work ==
1256 1256  
1257 -
1258 1258  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1259 1259  
1260 1260  
... ... @@ -1261,31 +1261,18 @@
1261 1261  == 8.2  Significant error between the output distant value of LiDAR and actual distance ==
1262 1262  
1263 1263  
1264 -(((
1265 -(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.)
1266 -)))
1261 +**(% style="color:blue" %)Cause ①**(%%):Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.)
1267 1267  
1268 -(((
1269 1269  Troubleshooting: Please avoid use of this product under such circumstance in practice.
1270 -)))
1271 1271  
1272 -(((
1273 -
1274 -)))
1275 1275  
1276 -(((
1277 -(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked.
1278 -)))
1266 +**(% style="color:blue" %)Cause ②**(%%): The IR-pass filters are blocked.
1279 1279  
1280 -(((
1281 -Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter.
1282 -)))
1268 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter
1283 1283  
1284 1284  
1285 -
1286 1286  = 9.  Order Info =
1287 1287  
1288 -
1289 1289  Part Number: (% style="color:blue" %)**LLDS12-XX**
1290 1290  
1291 1291  
... ... @@ -1301,6 +1301,7 @@
1301 1301  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1302 1302  
1303 1303  
1288 +
1304 1304  = 10. ​ Packing Info =
1305 1305  
1306 1306  
... ... @@ -1316,6 +1316,7 @@
1316 1316  * Weight / pcs : g
1317 1317  
1318 1318  
1304 +
1319 1319  = 11.  ​Support =
1320 1320  
1321 1321  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved