Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -L LDS12-LoRaWANLiDAR ToF DistanceSensor User Manual1 +LSPH01-LoRaWAN Soil pH Sensor User Manual - Content
-
... ... @@ -1,9 +1,65 @@ 1 1 (% style="text-align:center" %) 2 -[[image: image-20220610095606-1.png]]2 +[[image:1654592399090-860.png||height="521" width="483"]] 3 3 4 4 5 + 6 + 5 5 **Contents:** 6 6 9 +* [[1. Introduction>>path:#H1.Introduction]] 10 +** [[1.1 What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]] 11 +** [[1.2 Features>>path:#H200B1.2Features]] 12 +** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]] 13 +** [[1.4 Applications>>path:#H1.4200BApplications]] 14 +** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]] 15 +* [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]] 16 +** [[2.1 How it works>>path:#H2.1Howitworks]] 17 +** [[2.2 Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]] 18 +** [[2.3 Uplink Payload>>path:#H2.3200BUplinkPayload]] 19 +*** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]] 20 +*** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]] 21 +*** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]] 22 +*** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]] 23 +*** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]] 24 +*** [[2.3.6 Message Type>>path:#H2.3.6MessageType]] 25 +*** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]] 26 +** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]] 27 +** [[2.5 Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]] 28 +** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]] 29 +*** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]] 30 +*** [[2.6.2 Measurement>>path:#H2.6.2Measurement]] 31 +*** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]] 32 +** [[2.7 Calibration>>path:#H2.7Calibration]] 33 +** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]] 34 +*** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]] 35 +*** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]] 36 +*** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]] 37 +*** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]] 38 +*** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]] 39 +*** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]] 40 +*** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]] 41 +** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]] 42 +** [[2.10 Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]] 43 +* [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]] 44 +** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]] 45 +** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]] 46 +** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]] 47 +** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]] 48 +* [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]] 49 +** [[4.1 Battery Type>>path:#H4.1BatteryType]] 50 +** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]] 51 +** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]] 52 +*** [[4.3.1 Battery Note>>path:#H4.3.1200BBatteryNote]] 53 +*** [[4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]] 54 +* [[5. Use AT Command>>path:#H5.UseATCommand]] 55 +** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]] 56 +* [[6. FAQ>>path:#H6.FAQ]] 57 +** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]] 58 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]] 59 +** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]] 60 +* [[8. Order Info>>path:#H8.OrderInfo]] 61 +* [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 +* [[10. Support>>path:#H10.A0200BSupport]] 7 7 8 8 9 9 ... ... @@ -10,29 +10,35 @@ 10 10 11 11 12 12 13 -= 1. Introduction = 14 14 15 -== 1.1 What is LoRaWAN LiDAR ToF Distance Sensor == 16 16 17 -((( 18 - 19 19 20 - The Dragino LLDS12 is a (% style="color:blue"%)**LoRaWAN LiDAR ToF (Time of Flight) Distance Sensor**(%%) for Internet of Things solution. It is capable to measure the distanceto an object as close as 10 centimeters (+/- 5cm up to6m) andas far as 12 meters (+/-1% starting at 6m)!. The LiDAR probeuses laser inductiontechnology for distance measurement.72 += 1. Introduction = 21 21 22 - TheLLDS12can be applied to scenarios suchs horizontaldistancemeasurement, parking management system,object proximityandpresence detection,intelligenttrashcan managementsystem, robot obstacle avoidance, automatic control,sewer, etc.74 +== 1.1 What is LoRaWAN Soil pH Sensor == 23 23 24 -It detects the distance between the measured object and the sensor, and uploads the value via wireless to LoRaWAN IoT Server. 76 +((( 77 +The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 78 +))) 25 25 26 -The LoRa wireless technology used in LLDS12 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 80 +((( 81 +LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use. 82 +))) 27 27 28 -LLDS12 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 84 +((( 85 +The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 86 +))) 29 29 30 -Each LLDS12 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 88 +((( 89 +LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 31 31 ))) 32 32 92 +((( 93 +Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 94 +))) 33 33 34 -[[image:1654826306458-414.png]] 35 35 97 +[[image:1654592435432-887.png]] 36 36 37 37 38 38 ... ... @@ -40,19 +40,20 @@ 40 40 41 41 * LoRaWAN 1.0.3 Class A 42 42 * Ultra-low power consumption 43 -* Laser technology for distance detection 44 -* Operating Range - 0.1m~~12m① 45 -* Accuracy - ±5cm@(0.1-6m), ±1%@(6m-12m) 105 +* Monitor soil pH with temperature compensation. 106 +* Monitor soil temperature 46 46 * Monitor Battery Level 108 +* Support pH calibration by end user 47 47 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865 48 48 * AT Commands to change parameters 49 49 * Uplink on periodically 50 50 * Downlink to change configure 113 +* IP66 Waterproof Enclosure 114 +* IP68 rate for the Sensor Probe 51 51 * 8500mAh Battery for long term use 52 52 53 53 54 54 55 - 56 56 == 1.3 Probe Specification == 57 57 58 58 ... ... @@ -75,11 +75,12 @@ 75 75 76 76 77 77 78 - 79 79 == 1.4 Applications == 80 80 81 81 * Smart Agriculture 82 82 145 + 146 + 83 83 == 1.5 Pin mapping and power on == 84 84 85 85 [[image:1654592472094-134.png]] ... ... @@ -95,7 +95,7 @@ 95 95 ))) 96 96 97 97 ((( 98 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >> ||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.162 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01. 99 99 ))) 100 100 101 101 ... ... @@ -181,17 +181,19 @@ 181 181 ))) 182 182 183 183 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 184 -|=(% style="width: 62.5px;" %)((( 185 -**Size (bytes)** 186 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1** 187 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)((( 188 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 248 +|((( 249 +**Size** 189 189 190 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 191 -)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|((( 192 -[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]] 251 +**(bytes)** 252 +)))|**2**|**2**|**2**|**2**|**1**|**1**|**1** 253 +|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|((( 254 +[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]] 255 + 256 +[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]] 257 +)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|((( 258 +[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]] 193 193 )))|Reserve|((( 194 -[[Message Type>> ||anchor="H2.3.6MessageType"]]260 +[[Message Type>>path:#H2.3.6MessageType]] 195 195 ))) 196 196 197 197 [[image:1654592721645-318.png]] ... ... @@ -247,7 +247,7 @@ 247 247 248 248 === 2.3.5 Interrupt Pin === 249 249 250 -This data field shows if this packet is generated by interrupt or not. [[Click here>> ||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.316 +This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up. 251 251 252 252 253 253 **Example:** ... ... @@ -269,11 +269,11 @@ 269 269 ))) 270 270 271 271 272 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width: 499px" %)273 -|= (% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**274 -| (% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]275 -| (% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]276 -| (% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]338 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 339 +|=**Message Type Code**|=**Description**|=**Payload** 340 +|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]] 341 +|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]] 342 +|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]] 277 277 278 278 === 2.3.7 Decode payload in The Things Network === 279 279 ... ... @@ -294,7 +294,7 @@ 294 294 295 295 == 2.4 Uplink Interval == 296 296 297 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>> doc:Main.End.WebHome||anchor="H4.1ChangeUplinkInterval"]]363 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]] 298 298 299 299 300 300 ... ... @@ -458,9 +458,11 @@ 458 458 (% style="color:#037691" %)**Calibration Payload** 459 459 460 460 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 461 -|=(% style="width: 62.5px;" %)((( 462 -**Size (bytes)** 463 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1** 527 +|((( 528 +**Size** 529 + 530 +**(bytes)** 531 +)))|**1**|**1**|**1**|**7**|**1** 464 464 |**Value**|((( 465 465 PH4 466 466 ... ... @@ -470,7 +470,7 @@ 470 470 471 471 Calibrate value 472 472 )))|Reserve|((( 473 -[[Message Type>> ||anchor="H2.3.6MessageType"]]541 +[[Message Type>>path:#H2.3.6MessageType]] 474 474 475 475 Always 0x03 476 476 ))) ... ... @@ -484,6 +484,7 @@ 484 484 * Reply to non-confirmed packet: 14 00 485 485 486 486 555 + 487 487 == 2.8 Frequency Plans == 488 488 489 489 ((( ... ... @@ -569,6 +569,7 @@ 569 569 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 570 570 571 571 641 + 572 572 === 2.8.3 CN470-510 (CN470) === 573 573 574 574 ((( ... ... @@ -901,6 +901,8 @@ 901 901 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 902 902 * Blink once when device transmit a packet. 903 903 974 + 975 + 904 904 == 2.10 Firmware Change Log == 905 905 906 906 ... ... @@ -920,7 +920,7 @@ 920 920 ))) 921 921 922 922 * ((( 923 -AT Command Connection: See [[FAQ>> ||anchor="H6.FAQ"]].995 +AT Command Connection: See [[FAQ>>path:#H6.FAQ]]. 924 924 ))) 925 925 * ((( 926 926 LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]] ... ... @@ -1031,7 +1031,7 @@ 1031 1031 1032 1032 == 3.3 Calibrate Sensor == 1033 1033 1034 -Detail See [[Calibration Guide>> ||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands1106 +Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands 1035 1035 1036 1036 1037 1037 ... ... @@ -1063,7 +1063,7 @@ 1063 1063 1064 1064 Version 1065 1065 )))|Sensor Type|Reserve|((( 1066 -[[Message Type>> ||anchor="H2.3.6MessageType"]]1138 +[[Message Type>>path:#H2.3.6MessageType]] 1067 1067 Always 0x02 1068 1068 ))) 1069 1069 ... ... @@ -1237,7 +1237,7 @@ 1237 1237 1238 1238 [[image:1654593712276-618.png]] 1239 1239 1240 -Valid AT Command please check [[Configure Device>> ||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].1312 +Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]. 1241 1241 1242 1242 1243 1243 = 6. FAQ = ... ... @@ -1244,7 +1244,7 @@ 1244 1244 1245 1245 == 6.1 How to change the LoRa Frequency Bands/Region == 1246 1246 1247 -You can follow the instructions for [[how to upgrade image>> ||anchor="H2.10200BFirmwareChangeLog"]].1319 +You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]]. 1248 1248 When downloading the images, choose the required image file for download. 1249 1249 1250 1250 ... ... @@ -1255,7 +1255,6 @@ 1255 1255 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1256 1256 1257 1257 1258 - 1259 1259 = 8. Order Info = 1260 1260 1261 1261 Part Number: (% style="color:blue" %)**LSPH01-XX**
- 1654826112831-311.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -257.0 KB - Content
- 1654826306458-414.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.3 KB - Content
- image-20220610095606-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -183.2 KB - Content