<
From version < 85.8 >
edited by Xiaoling
on 2022/06/08 11:35
To version < 87.2 >
edited by Xiaoling
on 2022/06/10 09:56
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LSPH01-LoRaWAN Soil pH Sensor User Manual
1 +LLDS12-LoRaWAN LiDAR ToF Distance Sensor User Manual
Content
... ... @@ -1,9 +1,7 @@
1 1  (% style="text-align:center" %)
2 -[[image:1654592399090-860.png||height="521" width="483"]]
2 +[[image:image-20220610095606-1.png]]
3 3  
4 4  
5 -
6 -
7 7  **Contents:**
8 8  
9 9  * [[1. Introduction>>path:#H1.Introduction]]
... ... @@ -111,6 +111,7 @@
111 111  * IP68 rate for the Sensor Probe
112 112  * 8500mAh Battery for long term use
113 113  
112 +
114 114  == 1.3 Probe Specification ==
115 115  
116 116  
... ... @@ -131,10 +131,12 @@
131 131  * IP68 Protection
132 132  * Length: 3.5 meters
133 133  
133 +
134 134  == 1.4 ​Applications ==
135 135  
136 136  * Smart Agriculture
137 137  
138 +
138 138  == 1.5 Pin mapping and power on ==
139 139  
140 140  [[image:1654592472094-134.png]]
... ... @@ -331,8 +331,6 @@
331 331  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
332 332  
333 333  
334 -
335 -
336 336  === 2.3.7 Decode payload in The Things Network ===
337 337  
338 338  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -352,7 +352,7 @@
352 352  
353 353  == 2.4 Uplink Interval ==
354 354  
355 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
354 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
356 356  
357 357  
358 358  
... ... @@ -516,11 +516,9 @@
516 516  (% style="color:#037691" %)**Calibration Payload**
517 517  
518 518  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
519 -|(((
520 -**Size**
521 -
522 -**(bytes)**
523 -)))|**1**|**1**|**1**|**7**|**1**
518 +|=(% style="width: 62.5px;" %)(((
519 +**Size (bytes)**
520 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
524 524  |**Value**|(((
525 525  PH4
526 526  
... ... @@ -543,6 +543,8 @@
543 543  * Reply to the confirmation package: 14 01
544 544  * Reply to non-confirmed packet: 14 00
545 545  
543 +
544 +
546 546  == 2.8 Frequency Plans ==
547 547  
548 548  (((
... ... @@ -627,6 +627,8 @@
627 627  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
628 628  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
629 629  
629 +
630 +
630 630  === 2.8.3 CN470-510 (CN470) ===
631 631  
632 632  (((
... ... @@ -736,6 +736,7 @@
736 736  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
737 737  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
738 738  
740 +
739 739  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
740 740  
741 741  (((
... ... @@ -959,6 +959,7 @@
959 959  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
960 960  * Blink once when device transmit a packet.
961 961  
964 +
962 962  == 2.10 ​Firmware Change Log ==
963 963  
964 964  
... ... @@ -1313,6 +1313,7 @@
1313 1313  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1314 1314  
1315 1315  
1319 +
1316 1316  = 8. Order Info =
1317 1317  
1318 1318  Part Number: (% style="color:blue" %)**LSPH01-XX**
1654826112831-311.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +257.0 KB
Content
image-20220610095606-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +183.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0