From version < 85.35 >
edited by Xiaoling
on 2022/06/08 13:45
To version < 85.10 >
edited by Xiaoling
on 2022/06/08 11:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -64,8 +64,6 @@
64 64  
65 65  
66 66  
67 -
68 -
69 69  = 1. Introduction =
70 70  
71 71  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -358,7 +358,7 @@
358 358  
359 359  == 2.4 Uplink Interval ==
360 360  
361 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
359 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
362 362  
363 363  
364 364  
... ... @@ -522,9 +522,11 @@
522 522  (% style="color:#037691" %)**Calibration Payload**
523 523  
524 524  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
525 -|=(% style="width: 62.5px;" %)(((
526 -**Size (bytes)**
527 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
523 +|(((
524 +**Size**
525 +
526 +**(bytes)**
527 +)))|**1**|**1**|**1**|**7**|**1**
528 528  |**Value**|(((
529 529  PH4
530 530  
... ... @@ -547,9 +547,6 @@
547 547  * Reply to the confirmation package: 14 01
548 548  * Reply to non-confirmed packet: 14 00
549 549  
550 -
551 -
552 -
553 553  == 2.8 Frequency Plans ==
554 554  
555 555  (((
... ... @@ -634,9 +634,6 @@
634 634  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
635 635  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
636 636  
637 -
638 -
639 -
640 640  === 2.8.3 CN470-510 (CN470) ===
641 641  
642 642  (((
... ... @@ -746,8 +746,6 @@
746 746  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
747 747  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
748 748  
749 -
750 -
751 751  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
752 752  
753 753  (((
... ... @@ -971,8 +971,6 @@
971 971  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
972 972  * Blink once when device transmit a packet.
973 973  
974 -
975 -
976 976  == 2.10 ​Firmware Change Log ==
977 977  
978 978  
... ... @@ -1327,7 +1327,6 @@
1327 1327  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1328 1328  
1329 1329  
1330 -
1331 1331  = 8. Order Info =
1332 1332  
1333 1333  Part Number: (% style="color:blue" %)**LSPH01-XX**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0