<
From version < 85.24 >
edited by Xiaoling
on 2022/06/08 11:51
To version < 85.3 >
edited by Xiaoling
on 2022/06/08 11:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -62,6 +62,12 @@
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 +
66 +
67 +
68 +
69 +
70 +
65 65  = 1. Introduction =
66 66  
67 67  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -91,7 +91,6 @@
91 91  
92 92  
93 93  
94 -
95 95  == ​1.2 Features ==
96 96  
97 97  * LoRaWAN 1.0.3 Class A
... ... @@ -109,8 +109,6 @@
109 109  * 8500mAh Battery for long term use
110 110  
111 111  
112 -
113 -
114 114  == 1.3 Probe Specification ==
115 115  
116 116  
... ... @@ -132,15 +132,11 @@
132 132  * Length: 3.5 meters
133 133  
134 134  
135 -
136 -
137 137  == 1.4 ​Applications ==
138 138  
139 139  * Smart Agriculture
140 140  
141 141  
142 -
143 -
144 144  == 1.5 Pin mapping and power on ==
145 145  
146 146  [[image:1654592472094-134.png]]
... ... @@ -242,10 +242,12 @@
242 242  )))
243 243  
244 244  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
245 -|=(% style="width: 62.5px;" %)(((
246 -**Size (bytes)**
247 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
248 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
244 +|(((
245 +**Size**
246 +
247 +**(bytes)**
248 +)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
249 +|**Value**|[[BAT>>||anchor="2.3.1BatteryInfo"]]|(((
249 249  [[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
250 250  
251 251  [[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
... ... @@ -330,11 +330,11 @@
330 330  )))
331 331  
332 332  
333 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
334 -|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
335 -|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
336 -|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
337 -|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
334 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
335 +|=**Message Type Code**|=**Description**|=**Payload**
336 +|0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
337 +|0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
338 +|0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
338 338  
339 339  === 2.3.7 Decode payload in The Things Network ===
340 340  
... ... @@ -355,7 +355,7 @@
355 355  
356 356  == 2.4 Uplink Interval ==
357 357  
358 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
359 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
359 359  
360 360  
361 361  
... ... @@ -519,9 +519,11 @@
519 519  (% style="color:#037691" %)**Calibration Payload**
520 520  
521 521  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
522 -|=(% style="width: 62.5px;" %)(((
523 -**Size (bytes)**
524 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
523 +|(((
524 +**Size**
525 +
526 +**(bytes)**
527 +)))|**1**|**1**|**1**|**7**|**1**
525 525  |**Value**|(((
526 526  PH4
527 527  
... ... @@ -545,7 +545,6 @@
545 545  * Reply to non-confirmed packet: 14 00
546 546  
547 547  
548 -
549 549  == 2.8 Frequency Plans ==
550 550  
551 551  (((
... ... @@ -630,6 +630,7 @@
630 630  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
631 631  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
632 632  
635 +
633 633  === 2.8.3 CN470-510 (CN470) ===
634 634  
635 635  (((
... ... @@ -962,6 +962,7 @@
962 962  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
963 963  * Blink once when device transmit a packet.
964 964  
968 +
965 965  == 2.10 ​Firmware Change Log ==
966 966  
967 967  
... ... @@ -1316,7 +1316,6 @@
1316 1316  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1317 1317  
1318 1318  
1319 -
1320 1320  = 8. Order Info =
1321 1321  
1322 1322  Part Number: (% style="color:blue" %)**LSPH01-XX**
... ... @@ -1333,9 +1333,6 @@
1333 1333  * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1334 1334  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1335 1335  
1336 -
1337 -
1338 -
1339 1339  = 9. ​Packing Info =
1340 1340  
1341 1341  
... ... @@ -1350,9 +1350,6 @@
1350 1350  * Package Size / pcs : cm
1351 1351  * Weight / pcs : g
1352 1352  
1353 -
1354 -
1355 -
1356 1356  = 10. ​Support =
1357 1357  
1358 1358  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0