<
From version < 85.15 >
edited by Xiaoling
on 2022/06/08 11:46
To version < 85.34 >
edited by Xiaoling
on 2022/06/08 13:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -62,6 +62,10 @@
62 62  * [[10. ​Support>>path:#H10.A0200BSupport]]
63 63  
64 64  
65 +
66 +
67 +
68 +
65 65  = 1. Introduction =
66 66  
67 67  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -110,7 +110,6 @@
110 110  
111 111  
112 112  
113 -
114 114  == 1.3 Probe Specification ==
115 115  
116 116  
... ... @@ -131,10 +131,14 @@
131 131  * IP68 Protection
132 132  * Length: 3.5 meters
133 133  
137 +
138 +
134 134  == 1.4 ​Applications ==
135 135  
136 136  * Smart Agriculture
137 137  
143 +
144 +
138 138  == 1.5 Pin mapping and power on ==
139 139  
140 140  [[image:1654592472094-134.png]]
... ... @@ -330,6 +330,8 @@
330 330  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
331 331  |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
332 332  
340 +
341 +
333 333  === 2.3.7 Decode payload in The Things Network ===
334 334  
335 335  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -349,7 +349,7 @@
349 349  
350 350  == 2.4 Uplink Interval ==
351 351  
352 -The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
361 +The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
353 353  
354 354  
355 355  
... ... @@ -538,8 +538,6 @@
538 538  * Reply to the confirmation package: 14 01
539 539  * Reply to non-confirmed packet: 14 00
540 540  
541 -
542 -
543 543  == 2.8 Frequency Plans ==
544 544  
545 545  (((
... ... @@ -624,6 +624,9 @@
624 624  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
625 625  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
626 626  
634 +
635 +
636 +
627 627  === 2.8.3 CN470-510 (CN470) ===
628 628  
629 629  (((
... ... @@ -733,6 +733,8 @@
733 733  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
734 734  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
735 735  
746 +
747 +
736 736  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
737 737  
738 738  (((
... ... @@ -956,6 +956,8 @@
956 956  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
957 957  * Blink once when device transmit a packet.
958 958  
971 +
972 +
959 959  == 2.10 ​Firmware Change Log ==
960 960  
961 961  
... ... @@ -1310,6 +1310,7 @@
1310 1310  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1311 1311  
1312 1312  
1327 +
1313 1313  = 8. Order Info =
1314 1314  
1315 1315  Part Number: (% style="color:blue" %)**LSPH01-XX**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0