Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -63,6 +63,9 @@ 63 63 64 64 65 65 66 + 67 + 68 + 66 66 = 1. Introduction = 67 67 68 68 == 1.1 What is LoRaWAN Soil pH Sensor == ... ... @@ -329,6 +329,7 @@ 329 329 |0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]] 330 330 |0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]] 331 331 335 + 332 332 === 2.3.7 Decode payload in The Things Network === 333 333 334 334 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -539,6 +539,7 @@ 539 539 * Reply to the confirmation package: 14 01 540 540 * Reply to non-confirmed packet: 14 00 541 541 546 + 542 542 == 2.8 Frequency Plans == 543 543 544 544 ((( ... ... @@ -625,7 +625,6 @@ 625 625 626 626 627 627 628 - 629 629 === 2.8.3 CN470-510 (CN470) === 630 630 631 631 ((( ... ... @@ -1050,11 +1050,9 @@ 1050 1050 ))) 1051 1051 * ((( 1052 1052 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1053 - 1054 - 1055 - 1056 1056 ))) 1057 1057 1059 + 1058 1058 == 3.2 Set Interrupt Mode == 1059 1059 1060 1060 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -1300,6 +1300,7 @@ 1300 1300 Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]. 1301 1301 1302 1302 1305 + 1303 1303 = 6. FAQ = 1304 1304 1305 1305 == 6.1 How to change the LoRa Frequency Bands/Region == ... ... @@ -1308,6 +1308,7 @@ 1308 1308 When downloading the images, choose the required image file for download. 1309 1309 1310 1310 1314 + 1311 1311 = 7. Trouble Shooting = 1312 1312 1313 1313 == 7.1 AT Commands input doesn’t work == ... ... @@ -1315,6 +1315,7 @@ 1315 1315 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1316 1316 1317 1317 1322 + 1318 1318 = 8. Order Info = 1319 1319 1320 1320 Part Number: (% style="color:blue" %)**LSPH01-XX** ... ... @@ -1332,6 +1332,7 @@ 1332 1332 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1333 1333 1334 1334 1340 + 1335 1335 = 9. Packing Info = 1336 1336 1337 1337 ... ... @@ -1347,6 +1347,7 @@ 1347 1347 * Weight / pcs : g 1348 1348 1349 1349 1356 + 1350 1350 = 10. Support = 1351 1351 1352 1352 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.