Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -429,8 +429,10 @@ 429 429 === 2.6.1 Before measurement === 430 430 431 431 ((( 432 +((( 432 432 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 433 433 ))) 435 +))) 434 434 435 435 436 436 ... ... @@ -437,24 +437,45 @@ 437 437 === 2.6.2 Measurement === 438 438 439 439 442 +((( 440 440 (% style="color:#4f81bd" %)**Measurement the soil surface:** 444 +))) 441 441 446 +((( 442 442 [[image:1654592946732-634.png]] 448 +))) 443 443 450 +((( 444 444 Choose the proper measuring position. Split the surface soil according to the measured deep. 452 +))) 445 445 454 +((( 446 446 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 456 +))) 447 447 458 +((( 448 448 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 460 +))) 449 449 462 +((( 450 450 Put soil over the probe after insert. And start to measure. 464 +))) 451 451 466 +((( 467 + 468 +))) 452 452 470 +((( 453 453 (% style="color:#4f81bd" %)**Measurement inside soil:** 472 +))) 454 454 474 +((( 455 455 Dig a hole with diameter > 20CM. 476 +))) 456 456 478 +((( 457 457 Insert the probe inside, method like measure the surface. 480 +))) 458 458 459 459 460 460 ... ... @@ -484,9 +484,13 @@ 484 484 485 485 == 2.7 Calibration == 486 486 510 +((( 487 487 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 512 +))) 488 488 514 +((( 489 489 After stable, user can use below command to calibrate. 516 +))) 490 490 491 491 [[image:image-20220607171149-4.png]] 492 492 ... ... @@ -493,7 +493,7 @@ 493 493 494 494 (% style="color:#037691" %)**Calibration Payload** 495 495 496 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 523 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 497 497 |((( 498 498 **Size** 499 499