Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1043,24 +1043,16 @@ 1043 1043 1044 1044 1045 1045 1046 -((( 1047 1047 (% style="color:#037691" %)**Downlink Command: 0x01** 1048 -))) 1049 1049 1050 -((( 1051 1051 Format: Command Code (0x01) followed by 3 bytes time value. 1052 -))) 1053 1053 1054 1054 ((( 1055 1055 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1056 1056 ))) 1057 1057 1058 -* ((( 1059 -Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1060 -))) 1061 -* ((( 1062 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1063 -))) 1054 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1055 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1064 1064 1065 1065 1066 1066 ... ... @@ -1073,31 +1073,15 @@ 1073 1073 [[image:image-20220607171716-9.png]] 1074 1074 1075 1075 1076 -((( 1077 1077 (% style="color:#037691" %)**Downlink Command: 0x06** 1078 -))) 1079 1079 1080 -((( 1081 1081 Format: Command Code (0x06) followed by 3 bytes. 1082 -))) 1083 1083 1084 -((( 1085 1085 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1086 -))) 1087 1087 1088 -* ((( 1089 -Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1090 -))) 1091 -* ((( 1092 -Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1093 -))) 1074 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1075 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1094 1094 1095 -((( 1096 - 1097 -))) 1098 - 1099 - 1100 - 1101 1101 == 3.3 Calibrate Sensor == 1102 1102 1103 1103 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -1272,13 +1272,9 @@ 1272 1272 1273 1273 === 4.3.2 Replace the battery === 1274 1274 1275 -((( 1276 1276 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1277 -))) 1278 1278 1279 -((( 1280 1280 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1281 -))) 1282 1282 1283 1283 1284 1284