930 930  === 2.8.7 IN865-867 (IN865) ===
931 931  
932 -(((
933 933  (% style="color:blue" %)**Uplink:**
934 -)))
935 935  
936 -(((
937 937  865.0625 - SF7BW125 to SF12BW125
938 -)))
939 939  
940 -(((
941 941  865.4025 - SF7BW125 to SF12BW125
942 -)))
943 943  
944 -(((
945 945  865.9850 - SF7BW125 to SF12BW125
946 -)))
947 947  
948 -(((
949 -
950 -)))
951 951  
952 -(((
953 953  (% style="color:blue" %)**Downlink:**
954 -)))
955 955  
956 -(((
957 957  Uplink channels 1-3 (RX1)
958 -)))
959 959  
960 -(((
961 961  866.550 - SF10BW125 (RX2)
962 -)))
963 963  
964 964  
965 965  
... ... @@ -985,51 +985,26 @@
985 985  
986 986  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
987 987  
988 -(((
989 989  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
990 -)))
991 991  
992 -* (((
993 -AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
994 -)))
995 -* (((
996 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
997 -)))
973 +* AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
974 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
998 998  
999 -(((
1000 1000  There are two kinds of commands to configure LSPH01, they are:
1001 -)))
1002 1002  
1003 -* (((
1004 -(% style="color:#4f81bd" %)** General Commands**.
1005 -)))
978 +* (% style="color:#4f81bd" %)** General Commands**.
1006 1006  
1007 -(((
1008 1008  These commands are to configure:
1009 -)))
1010 1010  
1011 -* (((
1012 -General system settings like: uplink interval.
1013 -)))
1014 -* (((
1015 -LoRaWAN protocol & radio related command.
1016 -)))
982 +* General system settings like: uplink interval.
983 +* LoRaWAN protocol & radio related command.
1017 1017  
1018 -(((
1019 1019  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1020 -)))
1021 1021  
1022 -(((
1023 -
1024 -)))
1025 1025  
1026 -* (((
1027 -(% style="color:#4f81bd" %)** Commands special design for LSPH01**
1028 -)))
988 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1029 1029  
1030 -(((
1031 1031  These commands only valid for LSPH01, as below:
1032 -)))
1033 1033  
1034 1034  
1035 1035  
... ... @@ -1047,9 +1047,7 @@
1047 1047  
1048 1048  Format: Command Code (0x01) followed by 3 bytes time value.
1049 1049  
1050 -(((
1051 1051  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1052 -)))
1053 1053  
1054 1054  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1055 1055  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds