From version < 74.13 >
edited by Xiaoling
on 2022/06/07 17:52
To version < 74.16 >
edited by Xiaoling
on 2022/06/07 17:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -985,26 +985,51 @@
985 985  
986 986  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
987 987  
988 +(((
988 988  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
990 +)))
989 989  
990 -* AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
991 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
992 +* (((
993 +AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
994 +)))
995 +* (((
996 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
997 +)))
992 992  
999 +(((
993 993  There are two kinds of commands to configure LSPH01, they are:
1001 +)))
994 994  
995 -* (% style="color:#4f81bd" %)** General Commands**.
1003 +* (((
1004 +(% style="color:#4f81bd" %)** General Commands**.
1005 +)))
996 996  
1007 +(((
997 997  These commands are to configure:
1009 +)))
998 998  
999 -* General system settings like: uplink interval.
1000 -* LoRaWAN protocol & radio related command.
1011 +* (((
1012 +General system settings like: uplink interval.
1013 +)))
1014 +* (((
1015 +LoRaWAN protocol & radio related command.
1016 +)))
1001 1001  
1018 +(((
1002 1002  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1020 +)))
1003 1003  
1022 +(((
1023 +
1024 +)))
1004 1004  
1005 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1026 +* (((
1027 +(% style="color:#4f81bd" %)** Commands special design for LSPH01**
1028 +)))
1006 1006  
1030 +(((
1007 1007  These commands only valid for LSPH01, as below:
1032 +)))
1008 1008  
1009 1009  
1010 1010  
... ... @@ -1018,14 +1018,24 @@
1018 1018  
1019 1019  
1020 1020  
1046 +(((
1021 1021  (% style="color:#037691" %)**Downlink Command: 0x01**
1048 +)))
1022 1022  
1050 +(((
1023 1023  Format: Command Code (0x01) followed by 3 bytes time value.
1052 +)))
1024 1024  
1054 +(((
1025 1025  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1056 +)))
1026 1026  
1027 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1028 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1058 +* (((
1059 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1060 +)))
1061 +* (((
1062 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1063 +)))
1029 1029  
1030 1030  
1031 1031  
... ... @@ -1038,14 +1038,24 @@
1038 1038  [[image:image-20220607171716-9.png]]
1039 1039  
1040 1040  
1076 +(((
1041 1041  (% style="color:#037691" %)**Downlink Command: 0x06**
1078 +)))
1042 1042  
1080 +(((
1043 1043  Format: Command Code (0x06) followed by 3 bytes.
1082 +)))
1044 1044  
1084 +(((
1045 1045  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1086 +)))
1046 1046  
1047 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1048 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1088 +* (((
1089 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1090 +)))
1091 +* (((
1092 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1093 +)))
1049 1049  
1050 1050  == 3.3 Calibrate Sensor ==
1051 1051  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0