70 70  = 1. Introduction =
71 71  
72 72  == 1.1 ​What is LoRaWAN Soil pH Sensor ==
... ... @@ -96,6 +96,7 @@
96 96  
97 97  
98 98  
94 +
99 99  == ​1.2 Features ==
100 100  
101 101  * LoRaWAN 1.0.3 Class A
... ... @@ -113,6 +113,8 @@
113 113  * 8500mAh Battery for long term use
114 114  
115 115  
112 +
113 +
116 116  == 1.3 Probe Specification ==
117 117  
118 118  
... ... @@ -134,11 +134,15 @@
134 134  * Length: 3.5 meters
135 135  
136 136  
135 +
136 +
137 137  == 1.4 ​Applications ==
138 138  
139 139  * Smart Agriculture
140 140  
141 141  
142 +
143 +
142 142  == 1.5 Pin mapping and power on ==
143 143  
144 144  [[image:1654592472094-134.png]]
... ... @@ -154,7 +154,7 @@
154 154  )))
155 155  
156 156  (((
157 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
159 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
158 158  )))
159 159  
160 160  
... ... @@ -240,19 +240,17 @@
240 240  )))
241 241  
242 242  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
243 -|(((
244 -**Size**
245 +|=(% style="width: 62.5px;" %)(((
246 +**Size (bytes)**
247 +)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
248 +|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
249 +[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
245 245  
246 -**(bytes)**
247 -)))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
248 -|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
249 -[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
250 -
251 -[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
252 -)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
253 -[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
251 +[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
252 +)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
253 +[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
254 254  )))|Reserve|(((
255 -[[Message Type>>path:#H2.3.6MessageType]]
255 +[[Message Type>>||anchor="H2.3.6MessageType"]]
256 256  )))
257 257  
258 258  [[image:1654592721645-318.png]]
... ... @@ -308,7 +308,7 @@
308 308  
309 309  === 2.3.5 Interrupt Pin ===
310 310  
311 -This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
311 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
312 312  
313 313  
314 314  **Example:**
... ... @@ -330,14 +330,12 @@
330 330  )))
331 331  
332 332  
333 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
334 -|=**Message Type Code**|=**Description**|=**Payload**
335 -|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
336 -|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
337 -|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
333 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
334 +|=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
335 +|(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
336 +|(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
337 +|(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
338 338  
339 -
340 -
341 341  === 2.3.7 Decode payload in The Things Network ===
342 342  
343 343  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -521,11 +521,9 @@
521 521  (% style="color:#037691" %)**Calibration Payload**
522 522  
523 523  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
524 -|(((
525 -**Size**
526 -
527 -**(bytes)**
528 -)))|**1**|**1**|**1**|**7**|**1**
522 +|=(% style="width: 62.5px;" %)(((
523 +**Size (bytes)**
524 +)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
529 529  |**Value**|(((
530 530  PH4
531 531  
... ... @@ -535,7 +535,7 @@
535 535  
536 536  Calibrate value
537 537  )))|Reserve|(((
538 -[[Message Type>>path:#H2.3.6MessageType]]
534 +[[Message Type>>||anchor="H2.3.6MessageType"]]
539 539  
540 540  Always 0x03
541 541  )))
... ... @@ -634,51 +634,91 @@
634 634  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
635 635  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
636 636  
637 -
638 -
639 -
640 640  === 2.8.3 CN470-510 (CN470) ===
641 641  
635 +(((
642 642  Used in China, Default use CHE=1
637 +)))
643 643  
639 +(((
644 644  (% style="color:blue" %)**Uplink:**
641 +)))
645 645  
643 +(((
646 646  486.3 - SF7BW125 to SF12BW125
645 +)))
647 647  
647 +(((
648 648  486.5 - SF7BW125 to SF12BW125
649 +)))
649 649  
651 +(((
650 650  486.7 - SF7BW125 to SF12BW125
653 +)))
651 651  
655 +(((
652 652  486.9 - SF7BW125 to SF12BW125
657 +)))
653 653  
659 +(((
654 654  487.1 - SF7BW125 to SF12BW125
661 +)))
655 655  
663 +(((
656 656  487.3 - SF7BW125 to SF12BW125
665 +)))
657 657  
667 +(((
658 658  487.5 - SF7BW125 to SF12BW125
669 +)))
659 659  
671 +(((
660 660  487.7 - SF7BW125 to SF12BW125
673 +)))
661 661  
675 +(((
676 +
677 +)))
662 662  
679 +(((
663 663  (% style="color:blue" %)**Downlink:**
681 +)))
664 664  
683 +(((
665 665  506.7 - SF7BW125 to SF12BW125
685 +)))
666 666  
687 +(((
667 667  506.9 - SF7BW125 to SF12BW125
689 +)))
668 668  
691 +(((
669 669  507.1 - SF7BW125 to SF12BW125
693 +)))
670 670  
695 +(((
671 671  507.3 - SF7BW125 to SF12BW125
697 +)))
672 672  
699 +(((
673 673  507.5 - SF7BW125 to SF12BW125
701 +)))
674 674  
703 +(((
675 675  507.7 - SF7BW125 to SF12BW125
705 +)))
676 676  
707 +(((
677 677  507.9 - SF7BW125 to SF12BW125
709 +)))
678 678  
711 +(((
679 679  508.1 - SF7BW125 to SF12BW125
713 +)))
680 680  
715 +(((
681 681  505.3 - SF12BW125 (RX2 downlink only)
717 +)))
682 682  
683 683  
684 684  
... ... @@ -703,7 +703,6 @@
703 703  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
704 704  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
705 705  
706 -
707 707  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
708 708  
709 709  (((
... ... @@ -814,56 +814,109 @@
814 814  
815 815  === 2.8.6 KR920-923 (KR920) ===
816 816  
852 +(((
817 817  (% style="color:blue" %)**Default channel:**
854 +)))
818 818  
856 +(((
819 819  922.1 - SF7BW125 to SF12BW125
858 +)))
820 820  
860 +(((
821 821  922.3 - SF7BW125 to SF12BW125
862 +)))
822 822  
864 +(((
823 823  922.5 - SF7BW125 to SF12BW125
866 +)))
824 824  
868 +(((
869 +
870 +)))
825 825  
872 +(((
826 826  (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
874 +)))
827 827  
876 +(((
828 828  922.1 - SF7BW125 to SF12BW125
878 +)))
829 829  
880 +(((
830 830  922.3 - SF7BW125 to SF12BW125
882 +)))
831 831  
884 +(((
832 832  922.5 - SF7BW125 to SF12BW125
886 +)))
833 833  
888 +(((
834 834  922.7 - SF7BW125 to SF12BW125
890 +)))
835 835  
892 +(((
836 836  922.9 - SF7BW125 to SF12BW125
894 +)))
837 837  
896 +(((
838 838  923.1 - SF7BW125 to SF12BW125
898 +)))
839 839  
900 +(((
840 840  923.3 - SF7BW125 to SF12BW125
902 +)))
841 841  
904 +(((
905 +
906 +)))
842 842  
908 +(((
843 843  (% style="color:blue" %)**Downlink:**
910 +)))
844 844  
912 +(((
845 845  Uplink channels 1-7(RX1)
914 +)))
846 846  
916 +(((
847 847  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
918 +)))
848 848  
849 849  
850 850  
851 851  === 2.8.7 IN865-867 (IN865) ===
852 852  
924 +(((
853 853  (% style="color:blue" %)**Uplink:**
926 +)))
854 854  
928 +(((
855 855  865.0625 - SF7BW125 to SF12BW125
930 +)))
856 856  
932 +(((
857 857  865.4025 - SF7BW125 to SF12BW125
934 +)))
858 858  
936 +(((
859 859  865.9850 - SF7BW125 to SF12BW125
938 +)))
860 860  
940 +(((
941 +
942 +)))
861 861  
944 +(((
862 862  (% style="color:blue" %)**Downlink:**
946 +)))
863 863  
948 +(((
864 864  Uplink channels 1-3 (RX1)
950 +)))
865 865  
952 +(((
866 866  866.550 - SF10BW125 (RX2)
954 +)))
867 867  
868 868  
869 869  
... ... @@ -874,7 +874,6 @@
874 874  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
875 875  * Blink once when device transmit a packet.
876 876  
877 -
878 878  == 2.10 ​Firmware Change Log ==
879 879  
880 880  
... ... @@ -889,26 +889,51 @@
889 889  
890 890  = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
891 891  
979 +(((
892 892  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
981 +)))
893 893  
894 -* AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
895 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
983 +* (((
984 +AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
985 +)))
986 +* (((
987 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
988 +)))
896 896  
990 +(((
897 897  There are two kinds of commands to configure LSPH01, they are:
992 +)))
898 898  
899 -* (% style="color:#4f81bd" %)** General Commands**.
994 +* (((
995 +(% style="color:#4f81bd" %)** General Commands**.
996 +)))
900 900  
998 +(((
901 901  These commands are to configure:
1000 +)))
902 902  
903 -* General system settings like: uplink interval.
904 -* LoRaWAN protocol & radio related command.
1002 +* (((
1003 +General system settings like: uplink interval.
1004 +)))
1005 +* (((
1006 +LoRaWAN protocol & radio related command.
1007 +)))
905 905  
1009 +(((
906 906  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1011 +)))
907 907  
1013 +(((
1014 +
1015 +)))
908 908  
909 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1017 +* (((
1018 +(% style="color:#4f81bd" %)** Commands special design for LSPH01**
1019 +)))
910 910  
1021 +(((
911 911  These commands only valid for LSPH01, as below:
1023 +)))
912 912  
913 913  
914 914  
... ... @@ -922,16 +922,27 @@
922 922  
923 923  
924 924  
1037 +(((
925 925  (% style="color:#037691" %)**Downlink Command: 0x01**
1039 +)))
926 926  
1041 +(((
927 927  Format: Command Code (0x01) followed by 3 bytes time value.
1043 +)))
928 928  
1045 +(((
929 929  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1047 +)))
930 930  
931 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
932 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1049 +* (((
1050 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1051 +)))
1052 +* (((
1053 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
933 933  
934 934  
1056 +
1057 +)))
935 935  
936 936  == 3.2 Set Interrupt Mode ==
937 937  
... ... @@ -942,18 +942,34 @@
942 942  [[image:image-20220607171716-9.png]]
943 943  
944 944  
1068 +(((
945 945  (% style="color:#037691" %)**Downlink Command: 0x06**
1070 +)))
946 946  
1072 +(((
947 947  Format: Command Code (0x06) followed by 3 bytes.
1074 +)))
948 948  
1076 +(((
949 949  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1078 +)))
950 950  
951 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
952 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1080 +* (((
1081 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1082 +)))
1083 +* (((
1084 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1085 +)))
953 953  
1087 +(((
1088 +
1089 +)))
1090 +
1091 +
1092 +
954 954  == 3.3 Calibrate Sensor ==
955 955  
956 -Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
1095 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
957 957  
958 958  
959 959  
... ... @@ -985,7 +985,7 @@
985 985  
986 986  Version
987 987  )))|Sensor Type|Reserve|(((
988 -[[Message Type>>path:#H2.3.6MessageType]]
1127 +[[Message Type>>||anchor="H2.3.6MessageType"]]
989 989  Always 0x02
990 990  )))
991 991  
... ... @@ -1125,9 +1125,13 @@
1125 1125  
1126 1126  === ​4.3.2 Replace the battery ===
1127 1127  
1267 +(((
1128 1128  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1269 +)))
1129 1129  
1271 +(((
1130 1130  The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1273 +)))
1131 1131  
1132 1132  
1133 1133  
... ... @@ -1148,24 +1148,24 @@
1148 1148  (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1149 1149  
1150 1150  
1294 +(((
1151 1151  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1296 +)))
1152 1152  
1153 1153  
1154 1154   [[image:1654593712276-618.png]]
1155 1155  
1156 -Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1301 +Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1157 1157  
1158 1158  
1159 -
1160 1160  = 6. FAQ =
1161 1161  
1162 1162  == 6.1 How to change the LoRa Frequency Bands/Region ==
1163 1163  
1164 -You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1308 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1165 1165  When downloading the images, choose the required image file for download. ​
1166 1166  
1167 1167  
1168 -
1169 1169  = 7. Trouble Shooting =
1170 1170  
1171 1171  == 7.1 AT Commands input doesn’t work ==
... ... @@ -1173,7 +1173,6 @@
1173 1173  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1174 1174  
1175 1175  
1176 -
1177 1177  = 8. Order Info =
1178 1178  
1179 1179  Part Number: (% style="color:blue" %)**LSPH01-XX**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0