Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -639,46 +639,89 @@ 639 639 640 640 === 2.8.3 CN470-510 (CN470) === 641 641 642 +((( 642 642 Used in China, Default use CHE=1 644 +))) 643 643 646 +((( 644 644 (% style="color:blue" %)**Uplink:** 648 +))) 645 645 650 +((( 646 646 486.3 - SF7BW125 to SF12BW125 652 +))) 647 647 654 +((( 648 648 486.5 - SF7BW125 to SF12BW125 656 +))) 649 649 658 +((( 650 650 486.7 - SF7BW125 to SF12BW125 660 +))) 651 651 662 +((( 652 652 486.9 - SF7BW125 to SF12BW125 664 +))) 653 653 666 +((( 654 654 487.1 - SF7BW125 to SF12BW125 668 +))) 655 655 670 +((( 656 656 487.3 - SF7BW125 to SF12BW125 672 +))) 657 657 674 +((( 658 658 487.5 - SF7BW125 to SF12BW125 676 +))) 659 659 678 +((( 660 660 487.7 - SF7BW125 to SF12BW125 680 +))) 661 661 682 +((( 683 + 684 +))) 662 662 686 +((( 663 663 (% style="color:blue" %)**Downlink:** 688 +))) 664 664 690 +((( 665 665 506.7 - SF7BW125 to SF12BW125 692 +))) 666 666 694 +((( 667 667 506.9 - SF7BW125 to SF12BW125 696 +))) 668 668 698 +((( 669 669 507.1 - SF7BW125 to SF12BW125 700 +))) 670 670 702 +((( 671 671 507.3 - SF7BW125 to SF12BW125 704 +))) 672 672 706 +((( 673 673 507.5 - SF7BW125 to SF12BW125 708 +))) 674 674 710 +((( 675 675 507.7 - SF7BW125 to SF12BW125 712 +))) 676 676 714 +((( 677 677 507.9 - SF7BW125 to SF12BW125 716 +))) 678 678 718 +((( 679 679 508.1 - SF7BW125 to SF12BW125 720 +))) 680 680 722 +((( 681 681 505.3 - SF12BW125 (RX2 downlink only) 724 +))) 682 682 683 683 684 684 ... ... @@ -814,56 +814,109 @@ 814 814 815 815 === 2.8.6 KR920-923 (KR920) === 816 816 860 +((( 817 817 (% style="color:blue" %)**Default channel:** 862 +))) 818 818 864 +((( 819 819 922.1 - SF7BW125 to SF12BW125 866 +))) 820 820 868 +((( 821 821 922.3 - SF7BW125 to SF12BW125 870 +))) 822 822 872 +((( 823 823 922.5 - SF7BW125 to SF12BW125 874 +))) 824 824 876 +((( 877 + 878 +))) 825 825 880 +((( 826 826 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)** 882 +))) 827 827 884 +((( 828 828 922.1 - SF7BW125 to SF12BW125 886 +))) 829 829 888 +((( 830 830 922.3 - SF7BW125 to SF12BW125 890 +))) 831 831 892 +((( 832 832 922.5 - SF7BW125 to SF12BW125 894 +))) 833 833 896 +((( 834 834 922.7 - SF7BW125 to SF12BW125 898 +))) 835 835 900 +((( 836 836 922.9 - SF7BW125 to SF12BW125 902 +))) 837 837 904 +((( 838 838 923.1 - SF7BW125 to SF12BW125 906 +))) 839 839 908 +((( 840 840 923.3 - SF7BW125 to SF12BW125 910 +))) 841 841 912 +((( 913 + 914 +))) 842 842 916 +((( 843 843 (% style="color:blue" %)**Downlink:** 918 +))) 844 844 920 +((( 845 845 Uplink channels 1-7(RX1) 922 +))) 846 846 924 +((( 847 847 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 926 +))) 848 848 849 849 850 850 851 851 === 2.8.7 IN865-867 (IN865) === 852 852 932 +((( 853 853 (% style="color:blue" %)**Uplink:** 934 +))) 854 854 936 +((( 855 855 865.0625 - SF7BW125 to SF12BW125 938 +))) 856 856 940 +((( 857 857 865.4025 - SF7BW125 to SF12BW125 942 +))) 858 858 944 +((( 859 859 865.9850 - SF7BW125 to SF12BW125 946 +))) 860 860 948 +((( 949 + 950 +))) 861 861 952 +((( 862 862 (% style="color:blue" %)**Downlink:** 954 +))) 863 863 956 +((( 864 864 Uplink channels 1-3 (RX1) 958 +))) 865 865 960 +((( 866 866 866.550 - SF10BW125 (RX2) 962 +))) 867 867 868 868 869 869 ... ... @@ -889,26 +889,51 @@ 889 889 890 890 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 891 891 988 +((( 892 892 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 990 +))) 893 893 894 -* AT Command Connection: See [[FAQ>>path:#H6.FAQ]]. 895 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]] 992 +* ((( 993 +AT Command Connection: See [[FAQ>>path:#H6.FAQ]]. 994 +))) 995 +* ((( 996 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]] 997 +))) 896 896 999 +((( 897 897 There are two kinds of commands to configure LSPH01, they are: 1001 +))) 898 898 899 -* (% style="color:#4f81bd" %)** General Commands**. 1003 +* ((( 1004 +(% style="color:#4f81bd" %)** General Commands**. 1005 +))) 900 900 1007 +((( 901 901 These commands are to configure: 1009 +))) 902 902 903 -* General system settings like: uplink interval. 904 -* LoRaWAN protocol & radio related command. 1011 +* ((( 1012 +General system settings like: uplink interval. 1013 +))) 1014 +* ((( 1015 +LoRaWAN protocol & radio related command. 1016 +))) 905 905 1018 +((( 906 906 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1020 +))) 907 907 1022 +((( 1023 + 1024 +))) 908 908 909 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01** 1026 +* ((( 1027 +(% style="color:#4f81bd" %)** Commands special design for LSPH01** 1028 +))) 910 910 1030 +((( 911 911 These commands only valid for LSPH01, as below: 1032 +))) 912 912 913 913 914 914 ... ... @@ -922,14 +922,24 @@ 922 922 923 923 924 924 1046 +((( 925 925 (% style="color:#037691" %)**Downlink Command: 0x01** 1048 +))) 926 926 1050 +((( 927 927 Format: Command Code (0x01) followed by 3 bytes time value. 1052 +))) 928 928 1054 +((( 929 929 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1056 +))) 930 930 931 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 932 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1058 +* ((( 1059 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1060 +))) 1061 +* ((( 1062 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1063 +))) 933 933 934 934 935 935 ... ... @@ -942,15 +942,31 @@ 942 942 [[image:image-20220607171716-9.png]] 943 943 944 944 1076 +((( 945 945 (% style="color:#037691" %)**Downlink Command: 0x06** 1078 +))) 946 946 1080 +((( 947 947 Format: Command Code (0x06) followed by 3 bytes. 1082 +))) 948 948 1084 +((( 949 949 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1086 +))) 950 950 951 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 952 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1088 +* ((( 1089 +Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1090 +))) 1091 +* ((( 1092 +Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1093 +))) 953 953 1095 +((( 1096 + 1097 +))) 1098 + 1099 + 1100 + 954 954 == 3.3 Calibrate Sensor == 955 955 956 956 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -1125,9 +1125,13 @@ 1125 1125 1126 1126 === 4.3.2 Replace the battery === 1127 1127 1275 +((( 1128 1128 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1277 +))) 1129 1129 1279 +((( 1130 1130 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1281 +))) 1131 1131 1132 1132 1133 1133 ... ... @@ -1148,7 +1148,9 @@ 1148 1148 (% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1149 1149 1150 1150 1302 +((( 1151 1151 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 1304 +))) 1152 1152 1153 1153 1154 1154 [[image:1654593712276-618.png]] ... ... @@ -1190,6 +1190,9 @@ 1190 1190 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1191 1191 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1192 1192 1346 + 1347 + 1348 + 1193 1193 = 9. Packing Info = 1194 1194 1195 1195 ... ... @@ -1204,6 +1204,9 @@ 1204 1204 * Package Size / pcs : cm 1205 1205 * Weight / pcs : g 1206 1206 1363 + 1364 + 1365 + 1207 1207 = 10. Support = 1208 1208 1209 1209 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.