Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,7 +55,6 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 - 59 59 == 1.3 Probe Specification == 60 60 61 61 ... ... @@ -95,7 +95,7 @@ 95 95 ))) 96 96 97 97 ((( 98 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 97 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.200BUseATCommand"]]to set the keys in the LSPH01. 99 99 ))) 100 100 101 101 ... ... @@ -262,11 +262,10 @@ 262 262 263 263 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 264 264 |**Message Type Code**|**Description**|**Payload** 265 -|0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3 200BUplinkPayload"]]264 +|0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3Uplink Payload"]] 266 266 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 267 267 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]] 268 268 269 - 270 270 === 2.3.7 Decode payload in The Things Network === 271 271 272 272 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -437,6 +437,7 @@ 437 437 * Reply to non-confirmed packet: 14 00 438 438 439 439 438 + 440 440 == 2.8 Frequency Plans == 441 441 442 442 ((( ... ... @@ -493,6 +493,7 @@ 493 493 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 494 494 495 495 495 + 496 496 === 2.8.3 CN470-510 (CN470) === 497 497 498 498 Used in China, Default use CHE=1 ... ... @@ -560,6 +560,8 @@ 560 560 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 561 561 562 562 563 + 564 + 563 563 === 2.8.5 AS920-923 & AS923-925 (AS923) === 564 564 565 565 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -674,6 +674,8 @@ 674 674 * Blink once when device transmit a packet. 675 675 676 676 679 + 680 + 677 677 == 2.10 Firmware Change Log == 678 678 679 679 ... ... @@ -743,7 +743,6 @@ 743 743 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 744 744 745 745 746 - 747 747 == 3.2 Set Interrupt Mode == 748 748 749 749 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -763,10 +763,9 @@ 763 763 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 764 764 765 765 766 - 767 767 == 3.3 Calibrate Sensor == 768 768 769 -Detail See [[Calibration Guide>>||anchor=" H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands771 +Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 770 770 771 771 772 772 ... ... @@ -781,6 +781,8 @@ 781 781 * Reply to the confirmation package: 26 01 782 782 * Reply to non-confirmed packet: 26 00 783 783 786 + 787 + 784 784 Device will send an uplink after got this downlink command. With below payload: 785 785 786 786 Configures info payload: ... ... @@ -896,12 +896,12 @@ 896 896 ))) 897 897 898 898 899 - **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:903 +Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 900 900 901 901 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 902 902 903 903 904 - **Step 2**: Open it and choose908 +Step 2: Open it and choose 905 905 906 906 * Product Model 907 907 * Uplink Interval ... ... @@ -909,103 +909,102 @@ 909 909 910 910 And the Life expectation in difference case will be shown on the right. 911 911 912 -[[image: 1654588577573-122.png]]916 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 913 913 914 914 915 915 The battery related documents as below: 916 916 917 -* ((( 918 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 921 +* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 922 +* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 923 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 924 + 925 +|((( 926 +JST-XH-2P connector 919 919 ))) 920 -* ((( 921 -[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 922 -))) 923 -* ((( 924 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 925 -))) 926 926 927 -[[image:image -20220607155856-8.png]]929 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 928 928 929 929 930 930 931 -=== 4.3.1 Battery Note === 933 +1. 934 +11. 935 +111. Battery Note 932 932 933 -((( 934 934 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 935 -))) 936 936 937 937 940 +1. 941 +11. 942 +111. Replace the battery 938 938 939 -=== 4.3.2 Replace the battery === 940 - 941 941 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 942 942 946 + 943 943 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 944 944 945 945 946 946 947 -= 5. Use AT Command = 948 948 949 -== 5.1 Access AT Commands == 950 950 953 + 954 +1. Use AT Command 955 +11. Access AT Commands 956 + 951 951 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 952 952 953 -[[image: 1654589001411-343.png]]959 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]] 954 954 955 - **Connection:**961 +Connection: 956 956 957 - (% style="background-color:yellow" %)**USB TTL GND <~-~-~-~-> GND**963 +USB TTL GND <~-~-~-~-> GND 958 958 959 - (% style="background-color:yellow" %)**USB TTL TXD**965 +USB TTL TXD <~-~-~-~-> UART_RXD 960 960 961 - (% style="background-color:yellow" %)**USB TTL RXD**967 +USB TTL RXD <~-~-~-~-> UART_TXD 962 962 963 963 964 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%)to access the serial console for LSPH01. LSPH01 will output system info once power on as below:970 +In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 965 965 966 966 967 - [[image: 1654589062541-567.png]]973 + [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]] 968 968 969 969 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 970 970 971 971 972 972 973 -= 6. FAQ = 974 974 975 -== 6.1 How to change the LoRa Frequency Bands/Region == 980 +1. FAQ 981 +11. How to change the LoRa Frequency Bands/Region 976 976 977 -You can follow the instructions for [[how to upgrade image>> ||anchor="H2.10200BFirmwareChangeLog"]].983 +You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 978 978 When downloading the images, choose the required image file for download. 979 979 980 980 981 981 982 -= 7. Trouble Shooting = 988 +1. Trouble Shooting 989 +11. AT Commands input doesn’t work 983 983 984 - ==7.1ATCommandsinput doesn’t work==991 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 985 985 986 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 987 987 994 +1. Order Info 988 988 996 +Part Number: **LSPH01-XX** 989 989 990 -= 8. Order Info = 991 991 992 - PartNumber:(% style="color:blue"%)**LSPH01-XX**999 +**XX**: The default frequency band 993 993 1001 +* **AS923**: LoRaWAN AS923 band 1002 +* **AU915**: LoRaWAN AU915 band 1003 +* **EU433**: LoRaWAN EU433 band 1004 +* **EU868**: LoRaWAN EU868 band 1005 +* **KR920**: LoRaWAN KR920 band 1006 +* **US915**: LoRaWAN US915 band 1007 +* **IN865**: LoRaWAN IN865 band 1008 +* **CN470**: LoRaWAN CN470 band 994 994 995 - (%style="color:blue" %)**XX**(%%): The default frequencyband1010 +1. Packing Info 996 996 997 -* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 998 -* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 999 -* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1000 -* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1001 -* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1002 -* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1003 -* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1004 -* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1005 - 1006 -= 9. Packing Info = 1007 - 1008 - 1009 1009 **Package Includes**: 1010 1010 1011 1011 * LSPH01 LoRaWAN Soil Ph Sensor x 1 ... ... @@ -1020,6 +1020,8 @@ 1020 1020 = 10. Support = 1021 1021 1022 1022 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1023 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].1026 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1024 1024 1028 +[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1029 + 1025 1025
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.0 KB - Content