Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -435,7 +435,6 @@ 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 437 438 - 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -493,7 +493,6 @@ 493 493 494 494 495 495 496 - 497 497 === 2.8.3 CN470-510 (CN470) === 498 498 499 499 Used in China, Default use CHE=1 ... ... @@ -560,7 +560,6 @@ 560 560 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 561 561 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 562 562 563 - 564 564 === 2.8.5 AS920-923 & AS923-925 (AS923) === 565 565 566 566 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -674,7 +674,6 @@ 674 674 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 675 675 * Blink once when device transmit a packet. 676 676 677 - 678 678 == 2.10 Firmware Change Log == 679 679 680 680 ... ... @@ -743,6 +743,8 @@ 743 743 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 744 744 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 745 745 742 + 743 + 746 746 == 3.2 Set Interrupt Mode == 747 747 748 748 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -761,6 +761,8 @@ 761 761 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 762 762 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 763 763 762 + 763 + 764 764 == 3.3 Calibrate Sensor == 765 765 766 766 Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -949,7 +949,7 @@ 949 949 950 950 [[image:1654589001411-343.png]] 951 951 952 -Connection: 952 +**Connection:** 953 953 954 954 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 955 955 ... ... @@ -958,7 +958,7 @@ 958 958 (% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 959 959 960 960 961 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 961 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 962 962 963 963 964 964 [[image:1654589062541-567.png]] ... ... @@ -968,17 +968,19 @@ 968 968 969 969 970 970 971 -1. FAQ 972 -11. How to change the LoRa Frequency Bands/Region 971 += 6. FAQ = 973 973 974 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 973 +== 6.1 How to change the LoRa Frequency Bands/Region == 974 + 975 +You can follow the instructions for [[how to upgrade image>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]]. 975 975 When downloading the images, choose the required image file for download. 976 976 977 977 978 978 979 -1. Trouble Shooting 980 -11. AT Commands input doesn’t work 980 += 7. Trouble Shooting = 981 981 982 +== 7.1 AT Commands input doesn’t work == 983 + 982 982 In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 983 983 984 984