Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -434,6 +434,7 @@ 434 434 * Reply to the confirmation package: 14 01 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 + 437 437 == 2.8 Frequency Plans == 438 438 439 439 ((( ... ... @@ -556,6 +556,8 @@ 556 556 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 557 557 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 558 558 560 + 561 + 559 559 === 2.8.5 AS920-923 & AS923-925 (AS923) === 560 560 561 561 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -671,7 +671,6 @@ 671 671 672 672 673 673 674 - 675 675 == 2.10 Firmware Change Log == 676 676 677 677 ... ... @@ -740,7 +740,6 @@ 740 740 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 741 741 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 742 742 743 - 744 744 == 3.2 Set Interrupt Mode == 745 745 746 746 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -759,7 +759,6 @@ 759 759 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 760 760 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 761 761 762 - 763 763 == 3.3 Calibrate Sensor == 764 764 765 765 Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -778,7 +778,6 @@ 778 778 * Reply to non-confirmed packet: 26 00 779 779 780 780 781 - 782 782 Device will send an uplink after got this downlink command. With below payload: 783 783 784 784 Configures info payload: ... ... @@ -938,31 +938,34 @@ 938 938 939 939 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 940 940 940 + 941 941 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 942 942 943 943 944 944 945 -= 5. Use AT Command = 946 946 947 -== 5.1 Access AT Commands == 948 948 947 + 948 +1. Use AT Command 949 +11. Access AT Commands 950 + 949 949 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 950 950 951 -[[image: 1654589001411-343.png]]953 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]] 952 952 953 - **Connection:**955 +Connection: 954 954 955 - (% style="background-color:yellow" %)**USB TTL GND <~-~-~-~-> GND**957 +USB TTL GND <~-~-~-~-> GND 956 956 957 - (% style="background-color:yellow" %)**USB TTL TXD**959 +USB TTL TXD <~-~-~-~-> UART_RXD 958 958 959 - (% style="background-color:yellow" %)**USB TTL RXD**961 +USB TTL RXD <~-~-~-~-> UART_TXD 960 960 961 961 962 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%)to access the serial console for LSPH01. LSPH01 will output system info once power on as below:964 +In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 963 963 964 964 965 - [[image: 1654589062541-567.png]]967 + [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]] 966 966 967 967 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 968 968 ... ... @@ -969,43 +969,38 @@ 969 969 970 970 971 971 972 -= 6. FAQ = 974 +1. FAQ 975 +11. How to change the LoRa Frequency Bands/Region 973 973 974 -== 6.1 How to change the LoRa Frequency Bands/Region == 975 - 976 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 977 +You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 977 977 When downloading the images, choose the required image file for download. 978 978 979 979 980 980 981 -= 7. Trouble Shooting = 982 +1. Trouble Shooting 983 +11. AT Commands input doesn’t work 982 982 983 - ==7.1ATCommandsinput doesn’t work==985 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 984 984 985 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 986 986 988 +1. Order Info 987 987 990 +Part Number: **LSPH01-XX** 988 988 989 -= 8. Order Info = 990 990 991 - PartNumber:(% style="color:blue"%)**LSPH01-XX**993 +**XX**: The default frequency band 992 992 995 +* **AS923**: LoRaWAN AS923 band 996 +* **AU915**: LoRaWAN AU915 band 997 +* **EU433**: LoRaWAN EU433 band 998 +* **EU868**: LoRaWAN EU868 band 999 +* **KR920**: LoRaWAN KR920 band 1000 +* **US915**: LoRaWAN US915 band 1001 +* **IN865**: LoRaWAN IN865 band 1002 +* **CN470**: LoRaWAN CN470 band 993 993 994 - (%style="color:blue" %)**XX**(%%): The default frequencyband1004 +1. Packing Info 995 995 996 -* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 997 -* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 998 -* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 999 -* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1000 -* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1001 -* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1002 -* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1003 -* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1004 - 1005 - 1006 -= 9. Packing Info = 1007 - 1008 - 1009 1009 **Package Includes**: 1010 1010 1011 1011 * LSPH01 LoRaWAN Soil Ph Sensor x 1
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.0 KB - Content