Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -493,6 +493,7 @@ 493 493 494 494 495 495 496 + 496 496 === 2.8.3 CN470-510 (CN470) === 497 497 498 498 Used in China, Default use CHE=1 ... ... @@ -560,8 +560,6 @@ 560 560 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 561 561 562 562 563 - 564 - 565 565 === 2.8.5 AS920-923 & AS923-925 (AS923) === 566 566 567 567 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -676,8 +676,6 @@ 676 676 * Blink once when device transmit a packet. 677 677 678 678 679 - 680 - 681 681 == 2.10 Firmware Change Log == 682 682 683 683 ... ... @@ -747,6 +747,8 @@ 747 747 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 748 748 749 749 747 + 748 + 750 750 == 3.2 Set Interrupt Mode == 751 751 752 752 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -765,7 +765,6 @@ 765 765 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 766 766 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 767 767 768 - 769 769 == 3.3 Calibrate Sensor == 770 770 771 771 Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -783,8 +783,6 @@ 783 783 * Reply to the confirmation package: 26 01 784 784 * Reply to non-confirmed packet: 26 00 785 785 786 - 787 - 788 788 Device will send an uplink after got this downlink command. With below payload: 789 789 790 790 Configures info payload: ... ... @@ -879,26 +879,33 @@ 879 879 880 880 == 4.2 Replace Battery == 881 881 878 +((( 882 882 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 880 +))) 883 883 882 +((( 884 884 And make sure the positive and negative pins match. 884 +))) 885 885 886 886 887 887 888 888 == 4.3 Power Consumption Analyze == 889 889 890 +((( 890 890 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 892 +))) 891 891 892 - 894 +((( 893 893 Instruction to use as below: 896 +))) 894 894 895 895 896 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 899 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 897 897 898 898 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 899 899 900 900 901 -Step 2: Open it and choose 904 +**Step 2**: Open it and choose 902 902 903 903 * Product Model 904 904 * Uplink Interval ... ... @@ -906,64 +906,62 @@ 906 906 907 907 And the Life expectation in difference case will be shown on the right. 908 908 909 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]912 +[[image:1654588577573-122.png]] 910 910 911 911 912 912 The battery related documents as below: 913 913 914 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 915 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 916 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 917 - 918 -|((( 919 -JST-XH-2P connector 917 +* ((( 918 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 920 920 ))) 920 +* ((( 921 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 922 +))) 923 +* ((( 924 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 925 +))) 921 921 922 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]927 +[[image:image-20220607155856-8.png]] 923 923 924 924 925 925 926 -1. 927 -11. 928 -111. Battery Note 931 +=== 4.3.1 Battery Note === 929 929 933 +((( 930 930 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 935 +))) 931 931 932 932 933 -1. 934 -11. 935 -111. Replace the battery 936 936 939 +=== 4.3.2 Replace the battery === 940 + 937 937 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 938 938 939 - 940 940 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 941 941 942 942 943 943 947 += 5. Use AT Command = 944 944 949 +== 5.1 Access AT Commands == 945 945 946 - 947 -1. Use AT Command 948 -11. Access AT Commands 949 - 950 950 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 951 951 952 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]953 +[[image:1654589001411-343.png]] 953 953 954 954 Connection: 955 955 956 -USB TTL GND <~-~-~-~-> GND 957 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 957 957 958 -USB TTL TXD <~-~-~-~-> UART_RXD 959 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 959 959 960 -USB TTL RXD <~-~-~-~-> UART_TXD 961 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 961 961 962 962 963 963 In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 964 964 965 965 966 - [[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]967 + [[image:1654589062541-567.png]] 967 967 968 968 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 969 969
- 1654588577573-122.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.2 KB - Content
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.0 KB - Content
- image-20220607155856-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content