... ... @@ -435,7 +435,6 @@ 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 437 438 - 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -559,9 +559,6 @@ 559 559 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 560 560 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 561 561 562 - 563 - 564 - 565 565 === 2.8.5 AS920-923 & AS923-925 (AS923) === 566 566 567 567 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -675,9 +675,6 @@ 675 675 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 676 676 * Blink once when device transmit a packet. 677 677 678 - 679 - 680 - 681 681 == 2.10 Firmware Change Log == 682 682 683 683 ... ... @@ -747,6 +747,7 @@ 747 747 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 748 748 749 749 743 + 750 750 == 3.2 Set Interrupt Mode == 751 751 752 752 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -766,6 +766,7 @@ 766 766 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 767 767 768 768 763 + 769 769 == 3.3 Calibrate Sensor == 770 770 771 771 Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -783,8 +783,6 @@ 783 783 * Reply to the confirmation package: 26 01 784 784 * Reply to non-confirmed packet: 26 00 785 785 786 - 787 - 788 788 Device will send an uplink after got this downlink command. With below payload: 789 789 790 790 Configures info payload: ... ... @@ -860,12 +860,15 @@ 860 860 861 861 == 4.1 Battery Type == 862 862 856 +((( 863 863 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 858 +))) 864 864 865 - 860 +((( 866 866 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 862 +))) 867 867 868 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]864 +[[image:1654588469844-778.png]] 869 869 870 870 871 871 Minimum Working Voltage for the LSPH01: ... ... @@ -873,30 +873,36 @@ 873 873 LSPH01: 2.45v ~~ 3.6v 874 874 875 875 876 -1. 877 -11. Replace Battery 878 878 873 +== 4.2 Replace Battery == 874 + 875 +((( 879 879 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 877 +))) 880 880 879 +((( 881 881 And make sure the positive and negative pins match. 881 +))) 882 882 883 883 884 884 885 -1. 886 -11. Power Consumption Analyze 885 +== 4.3 Power Consumption Analyze == 887 887 887 +((( 888 888 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 889 +))) 889 889 890 - 891 +((( 891 891 Instruction to use as below: 893 +))) 892 892 893 893 894 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 896 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 895 895 896 896 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 897 897 898 898 899 -Step 2: Open it and choose 901 +**Step 2**: Open it and choose 900 900 901 901 * Product Model 902 902 * Uplink Interval ... ... @@ -904,64 +904,62 @@ 904 904 905 905 And the Life expectation in difference case will be shown on the right. 906 906 907 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]909 +[[image:1654588577573-122.png]] 908 908 909 909 910 910 The battery related documents as below: 911 911 912 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 913 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 914 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 915 - 916 -|((( 917 -JST-XH-2P connector 914 +* ((( 915 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 918 918 ))) 917 +* ((( 918 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 919 +))) 920 +* ((( 921 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 922 +))) 919 919 920 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]924 +[[image:image-20220607155856-8.png]] 921 921 922 922 923 923 924 -1. 925 -11. 926 -111. Battery Note 928 +=== 4.3.1 Battery Note === 927 927 930 +((( 928 928 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 932 +))) 929 929 930 930 931 -1. 932 -11. 933 -111. Replace the battery 934 934 936 +=== 4.3.2 Replace the battery === 937 + 935 935 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 936 936 937 - 938 938 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 939 939 940 940 941 941 944 += 5. Use AT Command = 942 942 946 +== 5.1 Access AT Commands == 943 943 944 - 945 -1. Use AT Command 946 -11. Access AT Commands 947 - 948 948 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 949 949 950 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]950 +[[image:1654589001411-343.png]] 951 951 952 -Connection: 952 +**Connection:** 953 953 954 -USB TTL GND <~-~-~-~-> GND 954 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 955 955 956 -USB TTL TXD <~-~-~-~-> UART_RXD 956 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 957 957 958 -USB TTL RXD <~-~-~-~-> UART_TXD 958 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 959 959 960 960 961 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 961 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 962 962 963 963 964 - [[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]964 + [[image:1654589062541-567.png]] 965 965 966 966 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 967 967 ... ... @@ -968,17 +968,19 @@ 968 968 969 969 970 970 971 -1. FAQ 972 -11. How to change the LoRa Frequency Bands/Region 971 += 6. FAQ = 973 973 974 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 973 +== 6.1 How to change the LoRa Frequency Bands/Region == 974 + 975 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 975 975 When downloading the images, choose the required image file for download. 976 976 977 977 978 978 979 -1. Trouble Shooting 980 -11. AT Commands input doesn’t work 980 += 7. Trouble Shooting = 981 981 982 +== 7.1 AT Commands input doesn’t work == 983 + 982 982 In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 983 983 984 984
- 1654588577573-122.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.2 KB - Content
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.0 KB - Content
- image-20220607155856-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content