Changes for page LSN50v2-D20-D22-D23 LoRaWAN Temperature Sensor User Manual
Last modified by Xiaoling on 2024/01/17 16:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -427,6 +427,8 @@ 427 427 Always 0x03 428 428 ))) 429 429 430 + 431 + 430 430 User can also send 0x14 downlink command to poll the current calibration payload. 431 431 432 432 [[image:image-20220607145603-4.png]] ... ... @@ -561,7 +561,6 @@ 561 561 562 562 563 563 564 - 565 565 === 2.8.5 AS920-923 & AS923-925 (AS923) === 566 566 567 567 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -677,29 +677,35 @@ 677 677 678 678 679 679 680 - 681 681 == 2.10 Firmware Change Log == 682 682 683 - 684 684 **Firmware download link:** 685 685 686 686 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 687 687 688 688 689 -**Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]688 +**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]** 690 690 690 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]] 691 691 692 692 693 -= 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 694 694 694 + 695 + 696 + 697 +1. Configure LSPH01 via AT Command or LoRaWAN Downlink 698 + 695 695 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 696 696 697 -* AT Command Connection: See [[FAQ>> ||anchor="H6.FAQ"]].698 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]701 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]]. 702 +* LoRaWAN Downlink instruction for different platforms: 699 699 704 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]] 705 + 706 + 700 700 There are two kinds of commands to configure LSPH01, they are: 701 701 702 -* (% style="color:#4f81bd" %)**709 +* **General Commands**. 703 703 704 704 These commands are to configure: 705 705 ... ... @@ -706,25 +706,25 @@ 706 706 * General system settings like: uplink interval. 707 707 * LoRaWAN protocol & radio related command. 708 708 709 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]716 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 710 710 718 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 711 711 712 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01** 713 713 721 +* **Commands special design for LSPH01** 722 + 714 714 These commands only valid for LSPH01, as below: 715 715 716 716 726 +1. 727 +11. Set Transmit Interval Time 717 717 718 -== 3.1 Set Transmit Interval Time == 719 - 720 720 Feature: Change LoRaWAN End Node Transmit Interval. 721 721 722 - (% style="color:#037691" %)**AT Command: AT+TDC**731 +**AT Command: AT+TDC** 723 723 724 - 725 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %) 726 -|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response** 727 -|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)((( 733 +|**Command Example**|**Function**|**Response** 734 +|AT+TDC=?|Show current transmit Interval|((( 728 728 30000 729 729 730 730 OK ... ... @@ -731,13 +731,13 @@ 731 731 732 732 the interval is 30000ms = 30s 733 733 ))) 734 -| (% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((741 +|AT+TDC=60000|Set Transmit Interval|((( 735 735 OK 736 736 737 737 Set transmit interval to 60000ms = 60 seconds 738 738 ))) 739 739 740 - (% style="color:#037691" %)**Downlink Command: 0x01**747 +**Downlink Command: 0x01** 741 741 742 742 Format: Command Code (0x01) followed by 3 bytes time value. 743 743 ... ... @@ -746,18 +746,32 @@ 746 746 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 747 747 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 748 748 756 +1. 757 +11. Set Interrupt Mode 749 749 750 -== 3.2 Set Interrupt Mode == 751 - 752 752 Feature, Set Interrupt mode for GPIO_EXIT. 753 753 754 - (% style="color:#037691" %)**AT Command: AT+INTMOD**761 +**AT Command: AT+INTMOD** 755 755 756 -[[image:image-20220607153759-6.png]] 763 +|**Command Example**|**Function**|**Response** 764 +|AT+INTMOD=?|Show current interrupt mode|((( 765 +0 757 757 767 +OK 758 758 759 -(% style="color:#037691" %)**Downlink Command: 0x06** 769 +the mode is 0 = No interruption 770 +))) 771 +|AT+INTMOD=2|((( 772 +Set Transmit Interval 760 760 774 +1. (Disable Interrupt), 775 +1. (Trigger by rising and falling edge), 776 +1. (Trigger by falling edge) 777 +1. (Trigger by rising edge) 778 +)))|OK 779 + 780 +**Downlink Command: 0x06** 781 + 761 761 Format: Command Code (0x06) followed by 3 bytes. 762 762 763 763 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. ... ... @@ -765,34 +765,37 @@ 765 765 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 766 766 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 767 767 789 +1. 790 +11. Calibrate Sensor 768 768 769 - ==3.3CalibrateSensor==792 +Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands 770 770 771 -Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 772 772 773 773 796 +1. 797 +11. Get Firmware Version Info 774 774 775 -== 3.4 Get Firmware Version Info == 776 - 777 777 Feature: use downlink to get firmware version. 778 778 779 -(% style="color:#037691" %)**Downlink Command: 0x26** 780 780 781 - [[image:image-20220607154718-7.png]]802 +**Downlink Command: 0x26** 782 782 804 + 805 +|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)** 806 +|Get Firmware Version Info|Any|26|2 807 + 783 783 * Reply to the confirmation package: 26 01 784 784 * Reply to non-confirmed packet: 26 00 785 785 786 - 787 - 788 788 Device will send an uplink after got this downlink command. With below payload: 789 789 790 790 Configures info payload: 791 791 792 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 793 -|=((( 794 -**Size(bytes)** 795 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1** 815 +|((( 816 +**Size** 817 + 818 +**(bytes)** 819 +)))|**1**|**1**|**1**|**1**|**1**|**5**|**1** 796 796 |**Value**|Software Type|((( 797 797 Frequency 798 798 ... ... @@ -802,7 +802,10 @@ 802 802 803 803 Version 804 804 )))|Sensor Type|Reserve|((( 805 -[[Message Type>>||anchor="H2.3.6MessageType"]] 829 +[[Message>>path:#Message_Type]] 830 + 831 +[[Type>>path:#Message_Type]] 832 + 806 806 Always 0x02 807 807 ))) 808 808 ... ... @@ -856,10 +856,12 @@ 856 856 857 857 858 858 859 -= 4. Battery & How to replace = 860 860 861 -== 4.1 Battery Type == 862 862 888 + 889 +1. Battery & How to replace 890 +11. Battery Type 891 + 863 863 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 864 864 865 865
- image-20220607153237-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -12.9 KB - Content
- image-20220607153759-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content
- image-20220607154718-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.0 KB - Content