From version < 45.5 >
edited by Xiaoling
on 2022/10/27 11:53
To version < 42.5 >
edited by Xiaoling
on 2022/08/18 15:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,11 +22,11 @@
22 22  
23 23  = 1. Introduction =
24 24  
25 -
26 26  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
27 27  
28 -
29 29  (((
28 +
29 +
30 30  The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type.
31 31  )))
32 32  
... ... @@ -69,39 +69,33 @@
69 69  * IP66 Waterproof Enclosure
70 70  * 4000mAh or 8500mAh Battery for long term use
71 71  
72 -== 1.3 Specification ==
73 73  
74 74  
75 -Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
76 76  
77 -[[image:image-20220606162220-5.png]]
78 78  
76 +== 1.3 Specification ==
79 79  
80 80  
81 -== 1.4 Dimension ==
79 +Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
82 82  
81 +[[image:image-20220606162220-5.png]]
83 83  
84 -**Main Device Dimension:**
85 85  
86 -See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]]
87 87  
88 -[[image:image-20221008140228-2.png||height="358" width="571"]]
85 +== ​1.4 Applications ==
89 89  
90 90  
91 -**Probe Dimension**
88 +* Smart Agriculture
92 92  
93 -[[image:image-20221008135912-1.png]]
90 +(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
91 +​
94 94  
95 95  
96 96  
97 -== ​1.5 Applications ==
98 98  
96 +== 1.5 Firmware Change log ==
99 99  
100 -* Smart Agriculture​
101 101  
102 -== 1.6 Firmware Change log ==
103 -
104 -
105 105  **LSE01 v1.0 :**  Release
106 106  
107 107  
... ... @@ -182,33 +182,51 @@
182 182  Uplink payload includes in total 11 bytes.
183 183  )))
184 184  
185 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
186 -|=(% scope="row" %)(((
187 -**Size(bytes)**
179 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
180 +|(((
181 +**Size**
182 +
183 +**(bytes)**
188 188  )))|**2**|**2**|**2**|**2**|**2**|**1**
189 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
185 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
190 190  Temperature
187 +
191 191  (Reserve, Ignore now)
192 192  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
193 -MOD & Digital Interrupt(Optional)
190 +MOD & Digital Interrupt
191 +
192 +(Optional)
194 194  )))
195 195  
195 +
196 +
197 +
198 +
196 196  === 2.3.2 MOD~=1(Original value) ===
197 197  
198 198  
199 199  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
200 200  
201 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
202 -|=(% scope="row" %)(((
203 -**Size(bytes)**
204 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
205 +|(((
206 +**Size**
207 +
208 +**(bytes)**
204 204  )))|**2**|**2**|**2**|**2**|**2**|**1**
205 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
210 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
206 206  Temperature
212 +
207 207  (Reserve, Ignore now)
208 208  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
209 -MOD & Digital Interrupt(Optional)
215 +MOD & Digital Interrupt
216 +
217 +(Optional)
210 210  )))
211 211  
220 +
221 +
222 +
223 +
212 212  === 2.3.3 Battery Info ===
213 213  
214 214  
... ... @@ -322,7 +322,7 @@
322 322  )))
323 323  
324 324  (((
325 -LSE01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]
337 +LSE01 TTN Payload Decoder:  [[https:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]
326 326  )))
327 327  
328 328  
... ... @@ -656,7 +656,6 @@
656 656  
657 657  === 2.7.6 KR920-923 (KR920) ===
658 658  
659 -
660 660  Default channel:
661 661  
662 662  922.1 - SF7BW125 to SF12BW125
... ... @@ -693,7 +693,6 @@
693 693  
694 694  === 2.7.7 IN865-867 (IN865) ===
695 695  
696 -
697 697  (% style="color:#037691" %)** Uplink:**
698 698  
699 699  865.0625 - SF7BW125 to SF12BW125
... ... @@ -714,7 +714,6 @@
714 714  
715 715  == 2.8 LED Indicator ==
716 716  
717 -
718 718  The LSE01 has an internal LED which is to show the status of different state.
719 719  
720 720  * Blink once when device power on.
... ... @@ -721,15 +721,14 @@
721 721  * Solid ON for 5 seconds once device successful Join the network.
722 722  * Blink once when device transmit a packet.
723 723  
733 +
724 724  == 2.9 Installation in Soil ==
725 725  
726 -
727 727  **Measurement the soil surface**
728 728  
729 729  
730 730  [[image:1654506634463-199.png]] ​
731 731  
732 -
733 733  (((
734 734  (((
735 735  Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting.
... ... @@ -740,7 +740,6 @@
740 740  
741 741  [[image:1654506665940-119.png]]
742 742  
743 -
744 744  (((
745 745  Dig a hole with diameter > 20CM.
746 746  )))
... ... @@ -750,12 +750,14 @@
750 750  )))
751 751  
752 752  
753 -
754 754  == 2.10 ​Firmware Change Log ==
755 755  
762 +(((
763 +**Firmware download link:**
764 +)))
756 756  
757 757  (((
758 -**Firmware download link:  **[[https:~~/~~/www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0>>https://www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0]]
767 +[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
759 759  )))
760 760  
761 761  (((
... ... @@ -779,13 +779,10 @@
779 779  )))
780 780  
781 781  
782 -
783 783  == 2.11 ​Battery Analysis ==
784 784  
785 -
786 786  === 2.11.1 ​Battery Type ===
787 787  
788 -
789 789  (((
790 790  The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
791 791  )))
... ... @@ -816,7 +816,6 @@
816 816  
817 817  === 2.11.2 ​Battery Note ===
818 818  
819 -
820 820  (((
821 821  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
822 822  )))
... ... @@ -825,7 +825,6 @@
825 825  
826 826  === 2.11.3 Replace the battery ===
827 827  
828 -
829 829  (((
830 830  If Battery is lower than 2.7v, user should replace the battery of LSE01.
831 831  )))
... ... @@ -842,13 +842,11 @@
842 842  
843 843  = 3. ​Using the AT Commands =
844 844  
845 -
846 846  == 3.1 Access AT Commands ==
847 847  
848 848  
849 849  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
850 850  
851 -
852 852  [[image:1654501986557-872.png||height="391" width="800"]]
853 853  
854 854  
... ... @@ -865,7 +865,7 @@
865 865   [[image:1654502050864-459.png||height="564" width="806"]]
866 866  
867 867  
868 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]].
870 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]
869 869  
870 870  
871 871  (% style="background-color:#dcdcdc" %)**AT+<CMD>? **(%%) : Help on <CMD>
... ... @@ -973,13 +973,10 @@
973 973   (% style="background-color:#dcdcdc" %)**AT+CHE**(%%)  : Get or Set eight channels mode, Only for US915, AU915, CN470
974 974  
975 975  
976 -
977 977  = ​4. FAQ =
978 978  
979 -
980 980  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
981 981  
982 -
983 983  (((
984 984  You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
985 985  When downloading the images, choose the required image file for download. ​
... ... @@ -1048,36 +1048,27 @@
1048 1048  [[image:image-20220606154825-4.png]]
1049 1049  
1050 1050  
1051 -
1052 1052  == 4.2 ​Can I calibrate LSE01 to different soil types? ==
1053 1053  
1054 -
1055 1055  LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1056 1056  
1057 1057  
1058 -
1059 1059  = 5. Trouble Shooting =
1060 1060  
1061 -
1062 1062  == 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1063 1063  
1064 -
1065 1065  It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1066 1066  
1067 1067  
1068 -
1069 1069  == 5.2 AT Command input doesn't work ==
1070 1070  
1071 -
1072 1072  (((
1073 1073  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1074 1074  )))
1075 1075  
1076 1076  
1077 -
1078 1078  == 5.3 Device rejoin in at the second uplink packet ==
1079 1079  
1080 -
1081 1081  (% style="color:#4f81bd" %)**Issue describe as below:**
1082 1082  
1083 1083  [[image:1654500909990-784.png]]
... ... @@ -1097,7 +1097,6 @@
1097 1097  [[image:1654500929571-736.png||height="458" width="832"]]
1098 1098  
1099 1099  
1100 -
1101 1101  = 6. ​Order Info =
1102 1102  
1103 1103  
... ... @@ -1163,8 +1163,5 @@
1163 1163  
1164 1164  = 8. Support =
1165 1165  
1166 -
1167 1167  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1168 1168  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1169 -
1170 -
image-20221008135912-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -65.9 KB
Content
image-20221008140228-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -37.3 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0