Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,11 +22,11 @@ 22 22 23 23 = 1. Introduction = 24 24 25 - 26 26 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 27 27 28 - 29 29 ((( 28 + 29 + 30 30 The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 31 31 ))) 32 32 ... ... @@ -69,39 +69,33 @@ 69 69 * IP66 Waterproof Enclosure 70 70 * 4000mAh or 8500mAh Battery for long term use 71 71 72 -== 1.3 Specification == 73 73 74 74 75 -Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 76 76 77 -[[image:image-20220606162220-5.png]] 78 78 76 +== 1.3 Specification == 79 79 80 80 81 - ==1.4 Dimension==79 +Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 82 82 81 +[[image:image-20220606162220-5.png]] 83 83 84 -**Main Device Dimension:** 85 85 86 -See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 87 87 88 - [[image:image-20221008140228-2.png||height="358" width="571"]]85 +== 1.4 Applications == 89 89 90 90 91 -* *ProbeDimension**88 +* Smart Agriculture 92 92 93 -[[image:image-20221008135912-1.png]] 90 +(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 91 + 94 94 95 95 96 96 97 -== 1.5 Applications == 98 98 96 +== 1.5 Firmware Change log == 99 99 100 -* Smart Agriculture 101 101 102 -== 1.6 Firmware Change log == 103 - 104 - 105 105 **LSE01 v1.0 :** Release 106 106 107 107 ... ... @@ -182,31 +182,51 @@ 182 182 Uplink payload includes in total 11 bytes. 183 183 ))) 184 184 185 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 186 -|=(% scope="row" %)((( 187 -**Size(bytes)** 179 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 180 +|((( 181 +**Size** 182 + 183 +**(bytes)** 188 188 )))|**2**|**2**|**2**|**2**|**2**|**1** 189 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 190 -Temperature(Reserve, Ignore now) 185 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 186 +Temperature 187 + 188 +(Reserve, Ignore now) 191 191 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|((( 192 -MOD & Digital Interrupt(Optional) 190 +MOD & Digital Interrupt 191 + 192 +(Optional) 193 193 ))) 194 194 195 + 196 + 197 + 198 + 195 195 === 2.3.2 MOD~=1(Original value) === 196 196 197 197 198 198 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 199 199 200 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 201 -|=(% scope="row" %)((( 202 -**Size(bytes)** 204 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 205 +|((( 206 +**Size** 207 + 208 +**(bytes)** 203 203 )))|**2**|**2**|**2**|**2**|**2**|**1** 204 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 205 -Temperature(Reserve, Ignore now) 210 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 211 +Temperature 212 + 213 +(Reserve, Ignore now) 206 206 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 207 -MOD & Digital Interrupt(Optional) 215 +MOD & Digital Interrupt 216 + 217 +(Optional) 208 208 ))) 209 209 220 + 221 + 222 + 223 + 210 210 === 2.3.3 Battery Info === 211 211 212 212 ... ... @@ -320,7 +320,7 @@ 320 320 ))) 321 321 322 322 ((( 323 -LSE01 TTN Payload Decoder: [[https:~~/~~/ github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]337 +LSE01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]] 324 324 ))) 325 325 326 326 ... ... @@ -719,6 +719,10 @@ 719 719 * Solid ON for 5 seconds once device successful Join the network. 720 720 * Blink once when device transmit a packet. 721 721 736 + 737 + 738 + 739 + 722 722 == 2.9 Installation in Soil == 723 723 724 724 ... ... @@ -971,13 +971,10 @@ 971 971 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 972 972 973 973 974 - 975 975 = 4. FAQ = 976 976 977 - 978 978 == 4.1 How to change the LoRa Frequency Bands/Region? == 979 979 980 - 981 981 ((( 982 982 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 983 983 When downloading the images, choose the required image file for download. ... ... @@ -1046,36 +1046,27 @@ 1046 1046 [[image:image-20220606154825-4.png]] 1047 1047 1048 1048 1049 - 1050 1050 == 4.2 Can I calibrate LSE01 to different soil types? == 1051 1051 1052 - 1053 1053 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1054 1054 1055 1055 1056 - 1057 1057 = 5. Trouble Shooting = 1058 1058 1059 - 1060 1060 == 5.1 Why I can't join TTN in US915 / AU915 bands? == 1061 1061 1062 - 1063 1063 It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1064 1064 1065 1065 1066 - 1067 1067 == 5.2 AT Command input doesn't work == 1068 1068 1069 - 1070 1070 ((( 1071 1071 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1072 1072 ))) 1073 1073 1074 1074 1075 - 1076 1076 == 5.3 Device rejoin in at the second uplink packet == 1077 1077 1078 - 1079 1079 (% style="color:#4f81bd" %)**Issue describe as below:** 1080 1080 1081 1081 [[image:1654500909990-784.png]] ... ... @@ -1095,7 +1095,6 @@ 1095 1095 [[image:1654500929571-736.png||height="458" width="832"]] 1096 1096 1097 1097 1098 - 1099 1099 = 6. Order Info = 1100 1100 1101 1101 ... ... @@ -1161,8 +1161,5 @@ 1161 1161 1162 1162 = 8. Support = 1163 1163 1164 - 1165 1165 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1166 1166 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1167 - 1168 -
- image-20221008135912-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.9 KB - Content
- image-20221008140228-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.3 KB - Content