Version 85.33 by Xiaoling on 2022/06/08 13:44

Show last authors
1 (% style="text-align:center" %)
2 [[image:1654592399090-860.png||height="521" width="483"]]
3
4
5
6
7 **Contents:**
8
9 * [[1. Introduction>>path:#H1.Introduction]]
10 ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 ** [[​1.2 Features>>path:#H200B1.2Features]]
12 ** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 ** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 ** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 * [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 ** [[2.1 How it works>>path:#H2.1Howitworks]]
17 ** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 ** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 *** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 *** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 *** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 *** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 *** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 *** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 *** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 ** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 ** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 ** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 *** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 *** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 *** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 ** [[2.7 Calibration>>path:#H2.7Calibration]]
33 ** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 *** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 *** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 *** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 *** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 *** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 *** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 *** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 ** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 ** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 * [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 ** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 ** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 ** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 ** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 * [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 ** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 ** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 ** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 *** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 *** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 * [[5. Use AT Command>>path:#H5.UseATCommand]]
55 ** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 * [[6. FAQ>>path:#H6.FAQ]]
57 ** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 * [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 ** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 * [[8. Order Info>>path:#H8.OrderInfo]]
61 * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 * [[10. ​Support>>path:#H10.A0200BSupport]]
63
64
65
66
67
68
69 = 1. Introduction =
70
71 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
72
73 (((
74 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
75 )))
76
77 (((
78 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
79 )))
80
81 (((
82 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
83 )))
84
85 (((
86 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
87 )))
88
89 (((
90 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
91 )))
92
93
94 [[image:1654592435432-887.png]]
95
96
97
98
99 == ​1.2 Features ==
100
101 * LoRaWAN 1.0.3 Class A
102 * Ultra-low power consumption
103 * Monitor soil pH with temperature compensation.
104 * Monitor soil temperature
105 * Monitor Battery Level
106 * Support pH calibration by end user
107 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
108 * AT Commands to change parameters
109 * Uplink on periodically
110 * Downlink to change configure
111 * IP66 Waterproof Enclosure
112 * IP68 rate for the Sensor Probe
113 * 8500mAh Battery for long term use
114
115
116
117 == 1.3 Probe Specification ==
118
119
120 (% style="color:#4f81bd" %)**Soil pH:**
121
122 * Range: 3 ~~ 10 pH
123 * Resolution: 0.01 pH
124 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
125 * Temperature Compensation Range: 0 ~~ 50℃
126 * IP68 Protection
127 * Length: 3.5 meters
128
129 (% style="color:#4f81bd" %)**Soil Temperature:**
130
131 * Range -40℃~85℃
132 * Resolution: 0.1℃
133 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
134 * IP68 Protection
135 * Length: 3.5 meters
136
137
138
139 == 1.4 ​Applications ==
140
141 * Smart Agriculture
142
143 == 1.5 Pin mapping and power on ==
144
145 [[image:1654592472094-134.png]]
146
147
148
149 = 2. Configure LSPH01 to connect to LoRaWAN network =
150
151 == 2.1 How it works ==
152
153 (((
154 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
155 )))
156
157 (((
158 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
159 )))
160
161
162 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
163
164 (((
165 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
166 )))
167
168 (((
169 [[image:1654592492399-921.png]]
170 )))
171
172 (((
173 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
174 )))
175
176 (((
177 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
178 )))
179
180 (((
181 Each LSPH01 is shipped with a sticker with the default device EUI as below:
182 )))
183
184 [[image:image-20220607170145-1.jpeg]]
185
186
187
188 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
189
190
191 **Register the device**
192
193
194 [[image:1654592600093-601.png]]
195
196
197 **Add APP EUI and DEV EUI**
198
199 [[image:1654592619856-881.png]]
200
201
202 **Add APP EUI in the application**
203
204 [[image:1654592632656-512.png]]
205
206
207
208 **Add APP KEY**
209
210 [[image:1654592653453-934.png]]
211
212
213 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
214
215
216 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
217
218 [[image:image-20220607170442-2.png]]
219
220
221 (((
222 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
223 )))
224
225 [[image:1654592697690-910.png]]
226
227
228
229 == 2.3 ​Uplink Payload ==
230
231 (((
232 LSPH01 will uplink payload via LoRaWAN with below payload format: 
233 )))
234
235 (((
236 Uplink payload includes in total 11 bytes.
237 )))
238
239 (((
240 Normal uplink payload:
241 )))
242
243 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
244 |=(% style="width: 62.5px;" %)(((
245 **Size (bytes)**
246 )))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1**
247 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)(((
248 [[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
249
250 [[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
251 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
252 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
253 )))|Reserve|(((
254 [[Message Type>>||anchor="H2.3.6MessageType"]]
255 )))
256
257 [[image:1654592721645-318.png]]
258
259
260
261 === 2.3.1 Battery Info ===
262
263
264 Check the battery voltage for LSPH01.
265
266 Ex1: 0x0B45 = 2885mV
267
268 Ex2: 0x0B49 = 2889mV
269
270
271
272 === 2.3.2 DS18B20 Temperature sensor ===
273
274 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
275
276
277 **Example**:
278
279 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
280
281 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
282
283
284
285 === 2.3.3 Soil pH ===
286
287 Range: 0 ~~ 14 pH
288
289 **Example:**
290
291 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
292
293
294
295 === 2.3.4 Soil Temperature ===
296
297 Get Soil Temperature 
298
299
300 **Example**:
301
302 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
303
304 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
305
306
307
308 === 2.3.5 Interrupt Pin ===
309
310 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
311
312
313 **Example:**
314
315 0x00: Normal uplink packet.
316
317 0x01: Interrupt Uplink Packet.
318
319
320
321 === 2.3.6 Message Type ===
322
323 (((
324 For a normal uplink payload, the message type is always 0x01.
325 )))
326
327 (((
328 Valid Message Type:
329 )))
330
331
332 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:499px" %)
333 |=(% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**
334 |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
335 |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
336 |(% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]
337
338
339
340 === 2.3.7 Decode payload in The Things Network ===
341
342 While using TTN network, you can add the payload format to decode the payload.
343
344
345 [[image:1654592762713-715.png]]
346
347 (((
348 The payload decoder function for TTN is here:
349 )))
350
351 (((
352 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
353 )))
354
355
356
357 == 2.4 Uplink Interval ==
358
359 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
360
361
362
363 == 2.5 ​Show Data in DataCake IoT Server ==
364
365 (((
366 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
367 )))
368
369 (((
370
371 )))
372
373 (((
374 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
375 )))
376
377 (((
378 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
379 )))
380
381
382 [[image:1654592790040-760.png]]
383
384
385 [[image:1654592800389-571.png]]
386
387
388 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
389
390 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
391
392 [[image:1654592819047-535.png]]
393
394
395
396 [[image:1654592833877-762.png]]
397
398
399 [[image:1654592856403-259.png]]
400
401
402 (((
403 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
404 )))
405
406 (((
407 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
408 )))
409
410
411 [[image:1654592878525-845.png]]
412
413 [[image:1654592892967-474.png]]
414
415
416 [[image:1654592905354-123.png]]
417
418
419 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
420
421
422 [[image:1654592917530-261.png]]
423
424
425
426 == 2.6 Installation and Maintain ==
427
428 === 2.6.1 Before measurement ===
429
430 (((
431 (((
432 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
433 )))
434 )))
435
436
437
438 === 2.6.2 Measurement ===
439
440
441 (((
442 (% style="color:#4f81bd" %)**Measurement the soil surface:**
443 )))
444
445 (((
446 [[image:1654592946732-634.png]]
447 )))
448
449 (((
450 Choose the proper measuring position. Split the surface soil according to the measured deep.
451 )))
452
453 (((
454 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
455 )))
456
457 (((
458 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
459 )))
460
461 (((
462 Put soil over the probe after insert. And start to measure.
463 )))
464
465 (((
466
467 )))
468
469 (((
470 (% style="color:#4f81bd" %)**Measurement inside soil:**
471 )))
472
473 (((
474 Dig a hole with diameter > 20CM.
475 )))
476
477 (((
478 Insert the probe inside, method like measure the surface.
479 )))
480
481
482
483 === 2.6.3 Maintain Probe ===
484
485 1. (((
486 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
487 )))
488 1. (((
489 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
490 )))
491 1. (((
492 Probe reference electrode is also no strong, need to avoid strong force or hitting.
493 )))
494 1. (((
495 User should keep reference electrode wet while not use.
496 )))
497 1. (((
498 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
499 )))
500 1. (((
501 The probe is IP68 can be put in water.
502
503
504
505 )))
506
507 == 2.7 Calibration ==
508
509 (((
510 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
511 )))
512
513 (((
514 After stable, user can use below command to calibrate.
515 )))
516
517 [[image:image-20220607171149-4.png]]
518
519
520 (% style="color:#037691" %)**Calibration Payload**
521
522 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
523 |=(% style="width: 62.5px;" %)(((
524 **Size (bytes)**
525 )))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1**
526 |**Value**|(((
527 PH4
528
529 Calibrate value
530 )))|PH6.86 Calibrate value|(((
531 PH9.18
532
533 Calibrate value
534 )))|Reserve|(((
535 [[Message Type>>||anchor="H2.3.6MessageType"]]
536
537 Always 0x03
538 )))
539
540 User can also send 0x14 downlink command to poll the current calibration payload.
541
542 [[image:image-20220607171416-7.jpeg]]
543
544
545 * Reply to the confirmation package: 14 01
546 * Reply to non-confirmed packet: 14 00
547
548 == 2.8 Frequency Plans ==
549
550 (((
551 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
552 )))
553
554
555 === 2.8.1 EU863-870 (EU868) ===
556
557 (((
558 (% style="color:blue" %)**Uplink:**
559 )))
560
561 (((
562 868.1 - SF7BW125 to SF12BW125
563 )))
564
565 (((
566 868.3 - SF7BW125 to SF12BW125 and SF7BW250
567 )))
568
569 (((
570 868.5 - SF7BW125 to SF12BW125
571 )))
572
573 (((
574 867.1 - SF7BW125 to SF12BW125
575 )))
576
577 (((
578 867.3 - SF7BW125 to SF12BW125
579 )))
580
581 (((
582 867.5 - SF7BW125 to SF12BW125
583 )))
584
585 (((
586 867.7 - SF7BW125 to SF12BW125
587 )))
588
589 (((
590 867.9 - SF7BW125 to SF12BW125
591 )))
592
593 (((
594 868.8 - FSK
595 )))
596
597 (((
598
599 )))
600
601 (((
602 (% style="color:blue" %)**Downlink:**
603 )))
604
605 (((
606 Uplink channels 1-9 (RX1)
607 )))
608
609 (((
610 869.525 - SF9BW125 (RX2 downlink only)
611 )))
612
613
614
615 === 2.8.2 US902-928(US915) ===
616
617 (((
618 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
619 )))
620
621 (((
622 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
623 )))
624
625 (((
626 After Join success, the end node will switch to the correct sub band by:
627 )))
628
629 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
630 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
631
632
633
634
635 === 2.8.3 CN470-510 (CN470) ===
636
637 (((
638 Used in China, Default use CHE=1
639 )))
640
641 (((
642 (% style="color:blue" %)**Uplink:**
643 )))
644
645 (((
646 486.3 - SF7BW125 to SF12BW125
647 )))
648
649 (((
650 486.5 - SF7BW125 to SF12BW125
651 )))
652
653 (((
654 486.7 - SF7BW125 to SF12BW125
655 )))
656
657 (((
658 486.9 - SF7BW125 to SF12BW125
659 )))
660
661 (((
662 487.1 - SF7BW125 to SF12BW125
663 )))
664
665 (((
666 487.3 - SF7BW125 to SF12BW125
667 )))
668
669 (((
670 487.5 - SF7BW125 to SF12BW125
671 )))
672
673 (((
674 487.7 - SF7BW125 to SF12BW125
675 )))
676
677 (((
678
679 )))
680
681 (((
682 (% style="color:blue" %)**Downlink:**
683 )))
684
685 (((
686 506.7 - SF7BW125 to SF12BW125
687 )))
688
689 (((
690 506.9 - SF7BW125 to SF12BW125
691 )))
692
693 (((
694 507.1 - SF7BW125 to SF12BW125
695 )))
696
697 (((
698 507.3 - SF7BW125 to SF12BW125
699 )))
700
701 (((
702 507.5 - SF7BW125 to SF12BW125
703 )))
704
705 (((
706 507.7 - SF7BW125 to SF12BW125
707 )))
708
709 (((
710 507.9 - SF7BW125 to SF12BW125
711 )))
712
713 (((
714 508.1 - SF7BW125 to SF12BW125
715 )))
716
717 (((
718 505.3 - SF12BW125 (RX2 downlink only)
719 )))
720
721
722
723 === 2.8.4 AU915-928(AU915) ===
724
725 (((
726 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
727 )))
728
729 (((
730 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
731 )))
732
733 (((
734
735 )))
736
737 (((
738 After Join success, the end node will switch to the correct sub band by:
739 )))
740
741 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
742 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
743
744
745
746 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
747
748 (((
749 (% style="color:blue" %)**Default Uplink channel:**
750 )))
751
752 (((
753 923.2 - SF7BW125 to SF10BW125
754 )))
755
756 (((
757 923.4 - SF7BW125 to SF10BW125
758 )))
759
760 (((
761
762 )))
763
764 (((
765 (% style="color:blue" %)**Additional Uplink Channel**:
766 )))
767
768 (((
769 (OTAA mode, channel added by JoinAccept message)
770 )))
771
772 (((
773
774 )))
775
776 (((
777 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
778 )))
779
780 (((
781 922.2 - SF7BW125 to SF10BW125
782 )))
783
784 (((
785 922.4 - SF7BW125 to SF10BW125
786 )))
787
788 (((
789 922.6 - SF7BW125 to SF10BW125
790 )))
791
792 (((
793 922.8 - SF7BW125 to SF10BW125
794 )))
795
796 (((
797 923.0 - SF7BW125 to SF10BW125
798 )))
799
800 (((
801 922.0 - SF7BW125 to SF10BW125
802 )))
803
804 (((
805
806 )))
807
808 (((
809 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
810 )))
811
812 (((
813 923.6 - SF7BW125 to SF10BW125
814 )))
815
816 (((
817 923.8 - SF7BW125 to SF10BW125
818 )))
819
820 (((
821 924.0 - SF7BW125 to SF10BW125
822 )))
823
824 (((
825 924.2 - SF7BW125 to SF10BW125
826 )))
827
828 (((
829 924.4 - SF7BW125 to SF10BW125
830 )))
831
832 (((
833 924.6 - SF7BW125 to SF10BW125
834 )))
835
836 (((
837
838 )))
839
840 (((
841 (% style="color:blue" %)**Downlink:**
842 )))
843
844 (((
845 Uplink channels 1-8 (RX1)
846 )))
847
848 (((
849 923.2 - SF10BW125 (RX2)
850 )))
851
852
853
854 === 2.8.6 KR920-923 (KR920) ===
855
856 (((
857 (% style="color:blue" %)**Default channel:**
858 )))
859
860 (((
861 922.1 - SF7BW125 to SF12BW125
862 )))
863
864 (((
865 922.3 - SF7BW125 to SF12BW125
866 )))
867
868 (((
869 922.5 - SF7BW125 to SF12BW125
870 )))
871
872 (((
873
874 )))
875
876 (((
877 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
878 )))
879
880 (((
881 922.1 - SF7BW125 to SF12BW125
882 )))
883
884 (((
885 922.3 - SF7BW125 to SF12BW125
886 )))
887
888 (((
889 922.5 - SF7BW125 to SF12BW125
890 )))
891
892 (((
893 922.7 - SF7BW125 to SF12BW125
894 )))
895
896 (((
897 922.9 - SF7BW125 to SF12BW125
898 )))
899
900 (((
901 923.1 - SF7BW125 to SF12BW125
902 )))
903
904 (((
905 923.3 - SF7BW125 to SF12BW125
906 )))
907
908 (((
909
910 )))
911
912 (((
913 (% style="color:blue" %)**Downlink:**
914 )))
915
916 (((
917 Uplink channels 1-7(RX1)
918 )))
919
920 (((
921 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
922 )))
923
924
925
926 === 2.8.7 IN865-867 (IN865) ===
927
928 (((
929 (% style="color:blue" %)**Uplink:**
930 )))
931
932 (((
933 865.0625 - SF7BW125 to SF12BW125
934 )))
935
936 (((
937 865.4025 - SF7BW125 to SF12BW125
938 )))
939
940 (((
941 865.9850 - SF7BW125 to SF12BW125
942 )))
943
944 (((
945
946 )))
947
948 (((
949 (% style="color:blue" %)**Downlink:**
950 )))
951
952 (((
953 Uplink channels 1-3 (RX1)
954 )))
955
956 (((
957 866.550 - SF10BW125 (RX2)
958 )))
959
960
961
962 == 2.9 LED Indicator ==
963
964 The LSPH01 has an internal LED which is to show the status of different state.
965
966 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
967 * Blink once when device transmit a packet.
968
969
970
971 == 2.10 ​Firmware Change Log ==
972
973
974 **Firmware download link:**
975
976 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
977
978
979 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
980
981
982
983 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
984
985 (((
986 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
987 )))
988
989 * (((
990 AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
991 )))
992 * (((
993 LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
994 )))
995
996 (((
997 There are two kinds of commands to configure LSPH01, they are:
998 )))
999
1000 * (((
1001 (% style="color:#4f81bd" %)** General Commands**.
1002 )))
1003
1004 (((
1005 These commands are to configure:
1006 )))
1007
1008 * (((
1009 General system settings like: uplink interval.
1010 )))
1011 * (((
1012 LoRaWAN protocol & radio related command.
1013 )))
1014
1015 (((
1016 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1017 )))
1018
1019 (((
1020
1021 )))
1022
1023 * (((
1024 (% style="color:#4f81bd" %)** Commands special design for LSPH01**
1025 )))
1026
1027 (((
1028 These commands only valid for LSPH01, as below:
1029 )))
1030
1031
1032
1033 == 3.1 Set Transmit Interval Time ==
1034
1035 Feature: Change LoRaWAN End Node Transmit Interval.
1036
1037 (% style="color:#037691" %)**AT Command: AT+TDC**
1038
1039 [[image:image-20220607171554-8.png]]
1040
1041
1042
1043 (((
1044 (% style="color:#037691" %)**Downlink Command: 0x01**
1045 )))
1046
1047 (((
1048 Format: Command Code (0x01) followed by 3 bytes time value.
1049 )))
1050
1051 (((
1052 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1053 )))
1054
1055 * (((
1056 Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1057 )))
1058 * (((
1059 Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1060
1061
1062
1063 )))
1064
1065 == 3.2 Set Interrupt Mode ==
1066
1067 Feature, Set Interrupt mode for GPIO_EXIT.
1068
1069 (% style="color:#037691" %)**AT Command: AT+INTMOD**
1070
1071 [[image:image-20220607171716-9.png]]
1072
1073
1074 (((
1075 (% style="color:#037691" %)**Downlink Command: 0x06**
1076 )))
1077
1078 (((
1079 Format: Command Code (0x06) followed by 3 bytes.
1080 )))
1081
1082 (((
1083 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1084 )))
1085
1086 * (((
1087 Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1088 )))
1089 * (((
1090 Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1091 )))
1092
1093 (((
1094
1095 )))
1096
1097
1098
1099 == 3.3 Calibrate Sensor ==
1100
1101 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
1102
1103
1104
1105 == 3.4 Get Firmware Version Info ==
1106
1107 Feature: use downlink to get firmware version.
1108
1109 (% style="color:#037691" %)**Downlink Command: 0x26**
1110
1111 [[image:image-20220607171917-10.png]]
1112
1113 * Reply to the confirmation package: 26 01
1114 * Reply to non-confirmed packet: 26 00
1115
1116 Device will send an uplink after got this downlink command. With below payload:
1117
1118 Configures info payload:
1119
1120 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1121 |=(((
1122 **Size(bytes)**
1123 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
1124 |**Value**|Software Type|(((
1125 Frequency
1126
1127 Band
1128 )))|Sub-band|(((
1129 Firmware
1130
1131 Version
1132 )))|Sensor Type|Reserve|(((
1133 [[Message Type>>||anchor="H2.3.6MessageType"]]
1134 Always 0x02
1135 )))
1136
1137 **Software Type**: Always 0x03 for LSPH01
1138
1139
1140 **Frequency Band**:
1141
1142 *0x01: EU868
1143
1144 *0x02: US915
1145
1146 *0x03: IN865
1147
1148 *0x04: AU915
1149
1150 *0x05: KZ865
1151
1152 *0x06: RU864
1153
1154 *0x07: AS923
1155
1156 *0x08: AS923-1
1157
1158 *0x09: AS923-2
1159
1160 *0xa0: AS923-3
1161
1162
1163 **Sub-Band**: value 0x00 ~~ 0x08
1164
1165
1166 **Firmware Version**: 0x0100, Means: v1.0.0 version
1167
1168
1169 **Sensor Type**:
1170
1171 0x01: LSE01
1172
1173 0x02: LDDS75
1174
1175 0x03: LDDS20
1176
1177 0x04: LLMS01
1178
1179 0x05: LSPH01
1180
1181 0x06: LSNPK01
1182
1183 0x07: LDDS12
1184
1185
1186
1187 = 4. Battery & How to replace =
1188
1189 == 4.1 Battery Type ==
1190
1191 (((
1192 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1193 )))
1194
1195 (((
1196 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1197 )))
1198
1199 [[image:1654593587246-335.png]]
1200
1201
1202 Minimum Working Voltage for the LSPH01:
1203
1204 LSPH01:  2.45v ~~ 3.6v
1205
1206
1207
1208 == 4.2 Replace Battery ==
1209
1210 (((
1211 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1212 )))
1213
1214 (((
1215 And make sure the positive and negative pins match.
1216 )))
1217
1218
1219
1220 == 4.3 Power Consumption Analyze ==
1221
1222 (((
1223 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1224 )))
1225
1226 (((
1227 Instruction to use as below:
1228 )))
1229
1230
1231 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1232
1233 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1234
1235
1236 **Step 2**: Open it and choose
1237
1238 * Product Model
1239 * Uplink Interval
1240 * Working Mode
1241
1242 And the Life expectation in difference case will be shown on the right.
1243
1244 [[image:1654593605679-189.png]]
1245
1246
1247 The battery related documents as below:
1248
1249 * (((
1250 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1251 )))
1252 * (((
1253 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1254 )))
1255 * (((
1256 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1257 )))
1258
1259 [[image:image-20220607172042-11.png]]
1260
1261
1262
1263 === 4.3.1 ​Battery Note ===
1264
1265 (((
1266 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1267 )))
1268
1269
1270
1271 === ​4.3.2 Replace the battery ===
1272
1273 (((
1274 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1275 )))
1276
1277 (((
1278 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1279 )))
1280
1281
1282
1283 = 5. Use AT Command =
1284
1285 == 5.1 Access AT Commands ==
1286
1287 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1288
1289 [[image:1654593668970-604.png]]
1290
1291 **Connection:**
1292
1293 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
1294
1295 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
1296
1297 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1298
1299
1300 (((
1301 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1302 )))
1303
1304
1305 [[image:1654593712276-618.png]]
1306
1307 Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1308
1309
1310 = 6. FAQ =
1311
1312 == 6.1 How to change the LoRa Frequency Bands/Region ==
1313
1314 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1315 When downloading the images, choose the required image file for download. ​
1316
1317
1318 = 7. Trouble Shooting =
1319
1320 == 7.1 AT Commands input doesn’t work ==
1321
1322 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1323
1324
1325
1326 = 8. Order Info =
1327
1328 Part Number: (% style="color:blue" %)**LSPH01-XX**
1329
1330
1331 (% style="color:blue" %)**XX**(%%): The default frequency band
1332
1333 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
1334 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1335 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1336 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1337 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1338 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1339 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1340 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1341
1342 = 9. ​Packing Info =
1343
1344
1345 **Package Includes**:
1346
1347 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1348
1349 **Dimension and weight**:
1350
1351 * Device Size: cm
1352 * Device Weight: g
1353 * Package Size / pcs : cm
1354 * Weight / pcs : g
1355
1356 = 10. ​Support =
1357
1358 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1359 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1360
1361
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved