Show last authors
1 (% style="text-align:center" %)
2 [[image:1654592399090-860.png||height="521" width="483"]]
3
4
5
6
7 **Contents:**
8
9 * [[1. Introduction>>path:#H1.Introduction]]
10 ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 ** [[​1.2 Features>>path:#H200B1.2Features]]
12 ** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 ** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 ** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 * [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 ** [[2.1 How it works>>path:#H2.1Howitworks]]
17 ** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 ** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 *** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 *** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 *** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 *** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 *** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 *** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 *** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 ** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 ** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 ** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 *** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 *** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 *** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 ** [[2.7 Calibration>>path:#H2.7Calibration]]
33 ** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 *** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 *** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 *** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 *** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 *** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 *** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 *** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 ** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 ** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 * [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 ** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 ** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 ** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 ** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 * [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 ** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 ** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 ** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 *** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 *** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 * [[5. Use AT Command>>path:#H5.UseATCommand]]
55 ** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 * [[6. FAQ>>path:#H6.FAQ]]
57 ** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 * [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 ** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 * [[8. Order Info>>path:#H8.OrderInfo]]
61 * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 * [[10. ​Support>>path:#H10.A0200BSupport]]
63
64
65
66
67
68
69
70 = 1. Introduction =
71
72 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
73
74 (((
75 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
76 )))
77
78 (((
79 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
80 )))
81
82 (((
83 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
84 )))
85
86 (((
87 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
88 )))
89
90 (((
91 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
92 )))
93
94
95 [[image:1654592435432-887.png]]
96
97
98
99 == ​1.2 Features ==
100
101 * LoRaWAN 1.0.3 Class A
102 * Ultra-low power consumption
103 * Monitor soil pH with temperature compensation.
104 * Monitor soil temperature
105 * Monitor Battery Level
106 * Support pH calibration by end user
107 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
108 * AT Commands to change parameters
109 * Uplink on periodically
110 * Downlink to change configure
111 * IP66 Waterproof Enclosure
112 * IP68 rate for the Sensor Probe
113 * 8500mAh Battery for long term use
114
115
116 == 1.3 Probe Specification ==
117
118
119 (% style="color:#4f81bd" %)**Soil pH:**
120
121 * Range: 3 ~~ 10 pH
122 * Resolution: 0.01 pH
123 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
124 * Temperature Compensation Range: 0 ~~ 50℃
125 * IP68 Protection
126 * Length: 3.5 meters
127
128 (% style="color:#4f81bd" %)**Soil Temperature:**
129
130 * Range -40℃~85℃
131 * Resolution: 0.1℃
132 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
133 * IP68 Protection
134 * Length: 3.5 meters
135
136
137 == 1.4 ​Applications ==
138
139 * Smart Agriculture
140
141
142 == 1.5 Pin mapping and power on ==
143
144 [[image:1654592472094-134.png]]
145
146
147
148 = 2. Configure LSPH01 to connect to LoRaWAN network =
149
150 == 2.1 How it works ==
151
152 (((
153 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
154 )))
155
156 (((
157 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
158 )))
159
160
161 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
162
163 (((
164 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
165 )))
166
167 (((
168 [[image:1654592492399-921.png]]
169 )))
170
171 (((
172 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
173 )))
174
175 (((
176 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
177 )))
178
179 (((
180 Each LSPH01 is shipped with a sticker with the default device EUI as below:
181 )))
182
183 [[image:image-20220607170145-1.jpeg]]
184
185
186
187 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
188
189
190 **Register the device**
191
192
193 [[image:1654592600093-601.png]]
194
195
196 **Add APP EUI and DEV EUI**
197
198 [[image:1654592619856-881.png]]
199
200
201 **Add APP EUI in the application**
202
203 [[image:1654592632656-512.png]]
204
205
206
207 **Add APP KEY**
208
209 [[image:1654592653453-934.png]]
210
211
212 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
213
214
215 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
216
217 [[image:image-20220607170442-2.png]]
218
219
220 (((
221 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
222 )))
223
224 [[image:1654592697690-910.png]]
225
226
227
228 == 2.3 ​Uplink Payload ==
229
230 (((
231 LSPH01 will uplink payload via LoRaWAN with below payload format: 
232 )))
233
234 (((
235 Uplink payload includes in total 11 bytes.
236 )))
237
238 (((
239 Normal uplink payload:
240 )))
241
242 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
243 |(((
244 **Size**
245
246 **(bytes)**
247 )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
248 |**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
249 [[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
250
251 [[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
252 )))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
253 [[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
254 )))|Reserve|(((
255 [[Message Type>>path:#H2.3.6MessageType]]
256 )))
257
258 [[image:1654592721645-318.png]]
259
260
261
262 === 2.3.1 Battery Info ===
263
264
265 Check the battery voltage for LSPH01.
266
267 Ex1: 0x0B45 = 2885mV
268
269 Ex2: 0x0B49 = 2889mV
270
271
272
273 === 2.3.2 DS18B20 Temperature sensor ===
274
275 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
276
277
278 **Example**:
279
280 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
281
282 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
283
284
285
286 === 2.3.3 Soil pH ===
287
288 Range: 0 ~~ 14 pH
289
290 **Example:**
291
292 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
293
294
295
296 === 2.3.4 Soil Temperature ===
297
298 Get Soil Temperature 
299
300
301 **Example**:
302
303 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
304
305 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
306
307
308
309 === 2.3.5 Interrupt Pin ===
310
311 This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
312
313
314 **Example:**
315
316 0x00: Normal uplink packet.
317
318 0x01: Interrupt Uplink Packet.
319
320
321
322 === 2.3.6 Message Type ===
323
324 (((
325 For a normal uplink payload, the message type is always 0x01.
326 )))
327
328 (((
329 Valid Message Type:
330 )))
331
332
333 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
334 |=**Message Type Code**|=**Description**|=**Payload**
335 |0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
336 |0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
337 |0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
338
339
340
341 === 2.3.7 Decode payload in The Things Network ===
342
343 While using TTN network, you can add the payload format to decode the payload.
344
345
346 [[image:1654592762713-715.png]]
347
348 (((
349 The payload decoder function for TTN is here:
350 )))
351
352 (((
353 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
354 )))
355
356
357
358 == 2.4 Uplink Interval ==
359
360 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
361
362
363
364 == 2.5 ​Show Data in DataCake IoT Server ==
365
366 (((
367 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
368 )))
369
370 (((
371
372 )))
373
374 (((
375 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
376 )))
377
378 (((
379 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
380 )))
381
382
383 [[image:1654592790040-760.png]]
384
385
386 [[image:1654592800389-571.png]]
387
388
389 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
390
391 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
392
393 [[image:1654592819047-535.png]]
394
395
396
397 [[image:1654592833877-762.png]]
398
399
400 [[image:1654592856403-259.png]]
401
402
403 (((
404 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
405 )))
406
407 (((
408 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
409 )))
410
411
412 [[image:1654592878525-845.png]]
413
414 [[image:1654592892967-474.png]]
415
416
417 [[image:1654592905354-123.png]]
418
419
420 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
421
422
423 [[image:1654592917530-261.png]]
424
425
426
427 == 2.6 Installation and Maintain ==
428
429 === 2.6.1 Before measurement ===
430
431 (((
432 (((
433 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
434 )))
435 )))
436
437
438
439 === 2.6.2 Measurement ===
440
441
442 (((
443 (% style="color:#4f81bd" %)**Measurement the soil surface:**
444 )))
445
446 (((
447 [[image:1654592946732-634.png]]
448 )))
449
450 (((
451 Choose the proper measuring position. Split the surface soil according to the measured deep.
452 )))
453
454 (((
455 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
456 )))
457
458 (((
459 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
460 )))
461
462 (((
463 Put soil over the probe after insert. And start to measure.
464 )))
465
466 (((
467
468 )))
469
470 (((
471 (% style="color:#4f81bd" %)**Measurement inside soil:**
472 )))
473
474 (((
475 Dig a hole with diameter > 20CM.
476 )))
477
478 (((
479 Insert the probe inside, method like measure the surface.
480 )))
481
482
483
484 === 2.6.3 Maintain Probe ===
485
486 1. (((
487 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
488 )))
489 1. (((
490 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
491 )))
492 1. (((
493 Probe reference electrode is also no strong, need to avoid strong force or hitting.
494 )))
495 1. (((
496 User should keep reference electrode wet while not use.
497 )))
498 1. (((
499 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
500 )))
501 1. (((
502 The probe is IP68 can be put in water.
503
504
505
506 )))
507
508 == 2.7 Calibration ==
509
510 (((
511 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
512 )))
513
514 (((
515 After stable, user can use below command to calibrate.
516 )))
517
518 [[image:image-20220607171149-4.png]]
519
520
521 (% style="color:#037691" %)**Calibration Payload**
522
523 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
524 |(((
525 **Size**
526
527 **(bytes)**
528 )))|**1**|**1**|**1**|**7**|**1**
529 |**Value**|(((
530 PH4
531
532 Calibrate value
533 )))|PH6.86 Calibrate value|(((
534 PH9.18
535
536 Calibrate value
537 )))|Reserve|(((
538 [[Message Type>>path:#H2.3.6MessageType]]
539
540 Always 0x03
541 )))
542
543 User can also send 0x14 downlink command to poll the current calibration payload.
544
545 [[image:image-20220607171416-7.jpeg]]
546
547
548 * Reply to the confirmation package: 14 01
549 * Reply to non-confirmed packet: 14 00
550
551
552
553 == 2.8 Frequency Plans ==
554
555 (((
556 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
557 )))
558
559
560 === 2.8.1 EU863-870 (EU868) ===
561
562 (((
563 (% style="color:blue" %)**Uplink:**
564 )))
565
566 (((
567 868.1 - SF7BW125 to SF12BW125
568 )))
569
570 (((
571 868.3 - SF7BW125 to SF12BW125 and SF7BW250
572 )))
573
574 (((
575 868.5 - SF7BW125 to SF12BW125
576 )))
577
578 (((
579 867.1 - SF7BW125 to SF12BW125
580 )))
581
582 (((
583 867.3 - SF7BW125 to SF12BW125
584 )))
585
586 (((
587 867.5 - SF7BW125 to SF12BW125
588 )))
589
590 (((
591 867.7 - SF7BW125 to SF12BW125
592 )))
593
594 (((
595 867.9 - SF7BW125 to SF12BW125
596 )))
597
598 (((
599 868.8 - FSK
600 )))
601
602 (((
603
604 )))
605
606 (((
607 (% style="color:blue" %)**Downlink:**
608 )))
609
610 (((
611 Uplink channels 1-9 (RX1)
612 )))
613
614 (((
615 869.525 - SF9BW125 (RX2 downlink only)
616 )))
617
618
619
620 === 2.8.2 US902-928(US915) ===
621
622 (((
623 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
624 )))
625
626 (((
627 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
628 )))
629
630 (((
631 After Join success, the end node will switch to the correct sub band by:
632 )))
633
634 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
635 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
636
637
638
639
640 === 2.8.3 CN470-510 (CN470) ===
641
642 Used in China, Default use CHE=1
643
644 (% style="color:blue" %)**Uplink:**
645
646 486.3 - SF7BW125 to SF12BW125
647
648 486.5 - SF7BW125 to SF12BW125
649
650 486.7 - SF7BW125 to SF12BW125
651
652 486.9 - SF7BW125 to SF12BW125
653
654 487.1 - SF7BW125 to SF12BW125
655
656 487.3 - SF7BW125 to SF12BW125
657
658 487.5 - SF7BW125 to SF12BW125
659
660 487.7 - SF7BW125 to SF12BW125
661
662
663 (% style="color:blue" %)**Downlink:**
664
665 506.7 - SF7BW125 to SF12BW125
666
667 506.9 - SF7BW125 to SF12BW125
668
669 507.1 - SF7BW125 to SF12BW125
670
671 507.3 - SF7BW125 to SF12BW125
672
673 507.5 - SF7BW125 to SF12BW125
674
675 507.7 - SF7BW125 to SF12BW125
676
677 507.9 - SF7BW125 to SF12BW125
678
679 508.1 - SF7BW125 to SF12BW125
680
681 505.3 - SF12BW125 (RX2 downlink only)
682
683
684
685 === 2.8.4 AU915-928(AU915) ===
686
687 (((
688 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
689 )))
690
691 (((
692 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
693 )))
694
695 (((
696
697 )))
698
699 (((
700 After Join success, the end node will switch to the correct sub band by:
701 )))
702
703 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
704 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
705
706
707 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
708
709 (((
710 (% style="color:blue" %)**Default Uplink channel:**
711 )))
712
713 (((
714 923.2 - SF7BW125 to SF10BW125
715 )))
716
717 (((
718 923.4 - SF7BW125 to SF10BW125
719 )))
720
721 (((
722
723 )))
724
725 (((
726 (% style="color:blue" %)**Additional Uplink Channel**:
727 )))
728
729 (((
730 (OTAA mode, channel added by JoinAccept message)
731 )))
732
733 (((
734
735 )))
736
737 (((
738 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
739 )))
740
741 (((
742 922.2 - SF7BW125 to SF10BW125
743 )))
744
745 (((
746 922.4 - SF7BW125 to SF10BW125
747 )))
748
749 (((
750 922.6 - SF7BW125 to SF10BW125
751 )))
752
753 (((
754 922.8 - SF7BW125 to SF10BW125
755 )))
756
757 (((
758 923.0 - SF7BW125 to SF10BW125
759 )))
760
761 (((
762 922.0 - SF7BW125 to SF10BW125
763 )))
764
765 (((
766
767 )))
768
769 (((
770 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
771 )))
772
773 (((
774 923.6 - SF7BW125 to SF10BW125
775 )))
776
777 (((
778 923.8 - SF7BW125 to SF10BW125
779 )))
780
781 (((
782 924.0 - SF7BW125 to SF10BW125
783 )))
784
785 (((
786 924.2 - SF7BW125 to SF10BW125
787 )))
788
789 (((
790 924.4 - SF7BW125 to SF10BW125
791 )))
792
793 (((
794 924.6 - SF7BW125 to SF10BW125
795 )))
796
797 (((
798
799 )))
800
801 (((
802 (% style="color:blue" %)**Downlink:**
803 )))
804
805 (((
806 Uplink channels 1-8 (RX1)
807 )))
808
809 (((
810 923.2 - SF10BW125 (RX2)
811 )))
812
813
814
815 === 2.8.6 KR920-923 (KR920) ===
816
817 (% style="color:blue" %)**Default channel:**
818
819 922.1 - SF7BW125 to SF12BW125
820
821 922.3 - SF7BW125 to SF12BW125
822
823 922.5 - SF7BW125 to SF12BW125
824
825
826 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
827
828 922.1 - SF7BW125 to SF12BW125
829
830 922.3 - SF7BW125 to SF12BW125
831
832 922.5 - SF7BW125 to SF12BW125
833
834 922.7 - SF7BW125 to SF12BW125
835
836 922.9 - SF7BW125 to SF12BW125
837
838 923.1 - SF7BW125 to SF12BW125
839
840 923.3 - SF7BW125 to SF12BW125
841
842
843 (% style="color:blue" %)**Downlink:**
844
845 Uplink channels 1-7(RX1)
846
847 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
848
849
850
851 === 2.8.7 IN865-867 (IN865) ===
852
853 (% style="color:blue" %)**Uplink:**
854
855 865.0625 - SF7BW125 to SF12BW125
856
857 865.4025 - SF7BW125 to SF12BW125
858
859 865.9850 - SF7BW125 to SF12BW125
860
861
862 (% style="color:blue" %)**Downlink:**
863
864 Uplink channels 1-3 (RX1)
865
866 866.550 - SF10BW125 (RX2)
867
868
869
870 == 2.9 LED Indicator ==
871
872 The LSPH01 has an internal LED which is to show the status of different state.
873
874 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
875 * Blink once when device transmit a packet.
876
877
878 == 2.10 ​Firmware Change Log ==
879
880
881 **Firmware download link:**
882
883 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
884
885
886 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
887
888
889
890 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
891
892 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
893
894 * AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
895 * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
896
897 There are two kinds of commands to configure LSPH01, they are:
898
899 * (% style="color:#4f81bd" %)** General Commands**.
900
901 These commands are to configure:
902
903 * General system settings like: uplink interval.
904 * LoRaWAN protocol & radio related command.
905
906 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
907
908
909 * (% style="color:#4f81bd" %)** Commands special design for LSPH01**
910
911 These commands only valid for LSPH01, as below:
912
913
914
915 == 3.1 Set Transmit Interval Time ==
916
917 Feature: Change LoRaWAN End Node Transmit Interval.
918
919 (% style="color:#037691" %)**AT Command: AT+TDC**
920
921 [[image:image-20220607171554-8.png]]
922
923
924
925 (% style="color:#037691" %)**Downlink Command: 0x01**
926
927 Format: Command Code (0x01) followed by 3 bytes time value.
928
929 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
930
931 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
932 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
933
934
935
936 == 3.2 Set Interrupt Mode ==
937
938 Feature, Set Interrupt mode for GPIO_EXIT.
939
940 (% style="color:#037691" %)**AT Command: AT+INTMOD**
941
942 [[image:image-20220607171716-9.png]]
943
944
945 (% style="color:#037691" %)**Downlink Command: 0x06**
946
947 Format: Command Code (0x06) followed by 3 bytes.
948
949 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
950
951 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
952 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
953
954 == 3.3 Calibrate Sensor ==
955
956 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
957
958
959
960 == 3.4 Get Firmware Version Info ==
961
962 Feature: use downlink to get firmware version.
963
964 (% style="color:#037691" %)**Downlink Command: 0x26**
965
966 [[image:image-20220607171917-10.png]]
967
968 * Reply to the confirmation package: 26 01
969 * Reply to non-confirmed packet: 26 00
970
971 Device will send an uplink after got this downlink command. With below payload:
972
973 Configures info payload:
974
975 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
976 |=(((
977 **Size(bytes)**
978 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
979 |**Value**|Software Type|(((
980 Frequency
981
982 Band
983 )))|Sub-band|(((
984 Firmware
985
986 Version
987 )))|Sensor Type|Reserve|(((
988 [[Message Type>>path:#H2.3.6MessageType]]
989 Always 0x02
990 )))
991
992 **Software Type**: Always 0x03 for LSPH01
993
994
995 **Frequency Band**:
996
997 *0x01: EU868
998
999 *0x02: US915
1000
1001 *0x03: IN865
1002
1003 *0x04: AU915
1004
1005 *0x05: KZ865
1006
1007 *0x06: RU864
1008
1009 *0x07: AS923
1010
1011 *0x08: AS923-1
1012
1013 *0x09: AS923-2
1014
1015 *0xa0: AS923-3
1016
1017
1018 **Sub-Band**: value 0x00 ~~ 0x08
1019
1020
1021 **Firmware Version**: 0x0100, Means: v1.0.0 version
1022
1023
1024 **Sensor Type**:
1025
1026 0x01: LSE01
1027
1028 0x02: LDDS75
1029
1030 0x03: LDDS20
1031
1032 0x04: LLMS01
1033
1034 0x05: LSPH01
1035
1036 0x06: LSNPK01
1037
1038 0x07: LDDS12
1039
1040
1041
1042 = 4. Battery & How to replace =
1043
1044 == 4.1 Battery Type ==
1045
1046 (((
1047 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
1048 )))
1049
1050 (((
1051 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1052 )))
1053
1054 [[image:1654593587246-335.png]]
1055
1056
1057 Minimum Working Voltage for the LSPH01:
1058
1059 LSPH01:  2.45v ~~ 3.6v
1060
1061
1062
1063 == 4.2 Replace Battery ==
1064
1065 (((
1066 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
1067 )))
1068
1069 (((
1070 And make sure the positive and negative pins match.
1071 )))
1072
1073
1074
1075 == 4.3 Power Consumption Analyze ==
1076
1077 (((
1078 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
1079 )))
1080
1081 (((
1082 Instruction to use as below:
1083 )))
1084
1085
1086 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
1087
1088 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
1089
1090
1091 **Step 2**: Open it and choose
1092
1093 * Product Model
1094 * Uplink Interval
1095 * Working Mode
1096
1097 And the Life expectation in difference case will be shown on the right.
1098
1099 [[image:1654593605679-189.png]]
1100
1101
1102 The battery related documents as below:
1103
1104 * (((
1105 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
1106 )))
1107 * (((
1108 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
1109 )))
1110 * (((
1111 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
1112 )))
1113
1114 [[image:image-20220607172042-11.png]]
1115
1116
1117
1118 === 4.3.1 ​Battery Note ===
1119
1120 (((
1121 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
1122 )))
1123
1124
1125
1126 === ​4.3.2 Replace the battery ===
1127
1128 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1129
1130 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
1131
1132
1133
1134 = 5. Use AT Command =
1135
1136 == 5.1 Access AT Commands ==
1137
1138 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
1139
1140 [[image:1654593668970-604.png]]
1141
1142 **Connection:**
1143
1144 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
1145
1146 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
1147
1148 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1149
1150
1151 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1152
1153
1154 [[image:1654593712276-618.png]]
1155
1156 Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1157
1158
1159
1160 = 6. FAQ =
1161
1162 == 6.1 How to change the LoRa Frequency Bands/Region ==
1163
1164 You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1165 When downloading the images, choose the required image file for download. ​
1166
1167
1168
1169 = 7. Trouble Shooting =
1170
1171 == 7.1 AT Commands input doesn’t work ==
1172
1173 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1174
1175
1176
1177 = 8. Order Info =
1178
1179 Part Number: (% style="color:blue" %)**LSPH01-XX**
1180
1181
1182 (% style="color:blue" %)**XX**(%%): The default frequency band
1183
1184 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
1185 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1186 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1187 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1188 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1189 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1190 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1191 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1192
1193 = 9. ​Packing Info =
1194
1195
1196 **Package Includes**:
1197
1198 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1199
1200 **Dimension and weight**:
1201
1202 * Device Size: cm
1203 * Device Weight: g
1204 * Package Size / pcs : cm
1205 * Weight / pcs : g
1206
1207 = 10. ​Support =
1208
1209 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1210 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
1211
1212
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0