Show last authors
1 (% style="text-align:center" %)
2 [[image:1654592399090-860.png||height="521" width="483"]]
3
4
5
6
7 **Contents:**
8
9 * [[1. Introduction>>path:#H1.Introduction]]
10 ** [[1.1 ​What is LoRaWAN Soil pH Sensor>>path:#H1.1200BWhatisLoRaWANSoilpHSensor]]
11 ** [[​1.2 Features>>path:#H200B1.2Features]]
12 ** [[1.3 Probe Specification>>path:#H1.3ProbeSpecification]]
13 ** [[1.4 ​Applications>>path:#H1.4200BApplications]]
14 ** [[1.5 Pin mapping and power on>>path:#H1.5Pinmappingandpoweron]]
15 * [[2. Configure LSPH01 to connect to LoRaWAN network>>path:#H2.ConfigureLSPH01toconnecttoLoRaWANnetwork]]
16 ** [[2.1 How it works>>path:#H2.1Howitworks]]
17 ** [[2.2 ​Quick guide to connect to LoRaWAN server (OTAA)>>path:#H2.2200BQuickguidetoconnecttoLoRaWANserver28OTAA29]]
18 ** [[2.3 ​Uplink Payload>>path:#H2.3200BUplinkPayload]]
19 *** [[2.3.1 Battery Info>>path:#H2.3.1BatteryInfo]]
20 *** [[2.3.2 DS18B20 Temperature sensor>>path:#H2.3.2DS18B20Temperaturesensor]]
21 *** [[2.3.3 Soil pH>>path:#H2.3.3SoilpH]]
22 *** [[2.3.4 Soil Temperature>>path:#H2.3.4SoilTemperature]]
23 *** [[2.3.5 Interrupt Pin>>path:#H2.3.5InterruptPin]]
24 *** [[2.3.6 Message Type>>path:#H2.3.6MessageType]]
25 *** [[2.3.7 Decode payload in The Things Network>>path:#H2.3.7DecodepayloadinTheThingsNetwork]]
26 ** [[2.4 Uplink Interval>>path:#H2.4UplinkInterval]]
27 ** [[2.5 ​Show Data in DataCake IoT Server>>path:#H2.5200BShowDatainDataCakeIoTServer]]
28 ** [[2.6 Installation and Maintain>>path:#H2.6InstallationandMaintain]]
29 *** [[2.6.1 Before measurement>>path:#H2.6.1Beforemeasurement]]
30 *** [[2.6.2 Measurement>>path:#H2.6.2Measurement]]
31 *** [[2.6.3 Maintain Probe>>path:#H2.6.3MaintainProbe]]
32 ** [[2.7 Calibration>>path:#H2.7Calibration]]
33 ** [[2.8 Frequency Plans>>path:#H2.8FrequencyPlans]]
34 *** [[2.8.1 EU863-870 (EU868)>>path:#H2.8.1EU863-87028EU86829]]
35 *** [[2.8.2 US902-928(US915)>>path:#H2.8.2US902-92828US91529]]
36 *** [[2.8.3 CN470-510 (CN470)>>path:#H2.8.3CN470-51028CN47029]]
37 *** [[2.8.4 AU915-928(AU915)>>path:#H2.8.4AU915-92828AU91529]]
38 *** [[2.8.5 AS920-923 & AS923-925 (AS923)>>path:#H2.8.5AS920-92326AS923-92528AS92329]]
39 *** [[2.8.6 KR920-923 (KR920)>>path:#H2.8.6KR920-92328KR92029]]
40 *** [[2.8.7 IN865-867 (IN865)>>path:#H2.8.7IN865-86728IN86529]]
41 ** [[2.9 LED Indicator>>path:#H2.9LEDIndicator]]
42 ** [[2.10 ​Firmware Change Log>>path:#H2.10200BFirmwareChangeLog]]
43 * [[3. Configure LSPH01 via AT Command or LoRaWAN Downlink>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]
44 ** [[3.1 Set Transmit Interval Time>>path:#H3.1SetTransmitIntervalTime]]
45 ** [[3.2 Set Interrupt Mode>>path:#H3.2SetInterruptMode]]
46 ** [[3.3 Calibrate Sensor>>path:#H3.3CalibrateSensor]]
47 ** [[3.4 Get Firmware Version Info>>path:#H3.4GetFirmwareVersionInfo]]
48 * [[4. Battery & How to replace>>path:#H4.Battery26Howtoreplace]]
49 ** [[4.1 Battery Type>>path:#H4.1BatteryType]]
50 ** [[4.2 Replace Battery>>path:#H4.2ReplaceBattery]]
51 ** [[4.3 Power Consumption Analyze>>path:#H4.3PowerConsumptionAnalyze]]
52 *** [[4.3.1 ​Battery Note>>path:#H4.3.1200BBatteryNote]]
53 *** [[​4.3.2 Replace the battery>>path:#H200B4.3.2Replacethebattery]]
54 * [[5. Use AT Command>>path:#H5.UseATCommand]]
55 ** [[5.1 Access AT Commands>>path:#H5.1AccessATCommands]]
56 * [[6. FAQ>>path:#H6.FAQ]]
57 ** [[6.1 How to change the LoRa Frequency Bands/Region>>path:#H6.1HowtochangetheLoRaFrequencyBands2FRegion]]
58 * [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
59 ** [[7.1 AT Commands input doesn’t work>>path:#H7.1ATCommandsinputdoesn2019twork]]
60 * [[8. Order Info>>path:#H8.OrderInfo]]
61 * [[9. ​Packing Info>>path:#H9.200BPackingInfo]]
62 * [[10. ​Support>>path:#H10.A0200BSupport]]
63
64
65
66
67
68
69
70
71 = 1. Introduction =
72
73 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
74
75 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
76
77 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
78
79 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
80
81 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
82
83 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
84
85
86 [[image:1654592435432-887.png]]
87
88
89
90 == ​1.2 Features ==
91
92 * LoRaWAN 1.0.3 Class A
93 * Ultra-low power consumption
94 * Monitor soil pH with temperature compensation.
95 * Monitor soil temperature
96 * Monitor Battery Level
97 * Support pH calibration by end user
98 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
99 * AT Commands to change parameters
100 * Uplink on periodically
101 * Downlink to change configure
102 * IP66 Waterproof Enclosure
103 * IP68 rate for the Sensor Probe
104 * 8500mAh Battery for long term use
105
106
107
108 == 1.3 Probe Specification ==
109
110
111 (% style="color:#4f81bd" %)**Soil pH:**
112
113 * Range: 3 ~~ 10 pH
114 * Resolution: 0.01 pH
115 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
116 * Temperature Compensation Range: 0 ~~ 50℃
117 * IP68 Protection
118 * Length: 3.5 meters
119
120 (% style="color:#4f81bd" %)**Soil Temperature:**
121
122 * Range -40℃~85℃
123 * Resolution: 0.1℃
124 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
125 * IP68 Protection
126 * Length: 3.5 meters
127
128
129
130 == 1.4 ​Applications ==
131
132 * Smart Agriculture
133
134
135
136 == 1.5 Pin mapping and power on ==
137
138 [[image:1654592472094-134.png]]
139
140
141
142 = 2. Configure LSPH01 to connect to LoRaWAN network =
143
144 == 2.1 How it works ==
145
146 (((
147 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
148 )))
149
150 (((
151 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01.
152 )))
153
154
155 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
156
157 (((
158 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
159 )))
160
161 (((
162 [[image:1654592492399-921.png]]
163 )))
164
165 (((
166 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
167 )))
168
169 (((
170 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
171 )))
172
173 (((
174 Each LSPH01 is shipped with a sticker with the default device EUI as below:
175 )))
176
177 [[image:image-20220607170145-1.jpeg]]
178
179
180
181 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
182
183
184 **Register the device**
185
186
187 [[image:1654592600093-601.png]]
188
189
190 **Add APP EUI and DEV EUI**
191
192 [[image:1654592619856-881.png]]
193
194
195 **Add APP EUI in the application**
196
197 [[image:1654592632656-512.png]]
198
199
200
201 **Add APP KEY**
202
203 [[image:1654592653453-934.png]]
204
205
206 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
207
208
209 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
210
211 [[image:image-20220607170442-2.png]]
212
213
214 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
215
216 [[image:1654592697690-910.png]]
217
218
219
220 == 2.3 ​Uplink Payload ==
221
222 LSPH01 will uplink payload via LoRaWAN with below payload format: 
223
224 Uplink payload includes in total 11 bytes.
225
226 Normal uplink payload:
227
228 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
229 |(((
230 **Size**
231
232 **(bytes)**
233 )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
234 |**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|(((
235 [[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]]
236
237 [[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]]
238 )))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|(((
239 [[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]]
240 )))|Reserve|(((
241 [[Message Type>>path:#H2.3.6MessageType]]
242 )))
243
244 [[image:1654592721645-318.png]]
245
246
247
248 === 2.3.1 Battery Info ===
249
250
251 Check the battery voltage for LSPH01.
252
253 Ex1: 0x0B45 = 2885mV
254
255 Ex2: 0x0B49 = 2889mV
256
257
258
259 === 2.3.2 DS18B20 Temperature sensor ===
260
261 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
262
263
264 **Example**:
265
266 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
267
268 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
269
270
271
272 === 2.3.3 Soil pH ===
273
274 Range: 0 ~~ 14 pH
275
276 **Example:**
277
278 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
279
280
281
282 === 2.3.4 Soil Temperature ===
283
284 Get Soil Temperature 
285
286
287 **Example**:
288
289 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
290
291 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
292
293
294
295 === 2.3.5 Interrupt Pin ===
296
297 This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up.
298
299
300 **Example:**
301
302 0x00: Normal uplink packet.
303
304 0x01: Interrupt Uplink Packet.
305
306
307
308 === 2.3.6 Message Type ===
309
310 For a normal uplink payload, the message type is always 0x01.
311
312 Valid Message Type:
313
314
315 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
316 |**Message Type Code**|**Description**|**Payload**
317 |0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]]
318 |0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]]
319 |0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]]
320
321
322
323
324 === 2.3.7 Decode payload in The Things Network ===
325
326 While using TTN network, you can add the payload format to decode the payload.
327
328
329 [[image:1654592762713-715.png]]
330
331 (((
332 The payload decoder function for TTN is here:
333 )))
334
335 (((
336 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
337 )))
338
339
340
341 == 2.4 Uplink Interval ==
342
343 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval]]
344
345
346
347 == 2.5 ​Show Data in DataCake IoT Server ==
348
349 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
350
351
352 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
353
354 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
355
356
357 [[image:1654592790040-760.png]]
358
359
360 [[image:1654592800389-571.png]]
361
362
363 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
364
365 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
366
367 [[image:1654592819047-535.png]]
368
369
370
371 [[image:1654592833877-762.png]]
372
373
374 [[image:1654592856403-259.png]]
375
376
377 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
378
379 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
380
381
382 [[image:1654592878525-845.png]]
383
384 [[image:1654592892967-474.png]]
385
386
387 [[image:1654592905354-123.png]]
388
389
390 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
391
392
393 [[image:1654592917530-261.png]]
394
395
396
397 == 2.6 Installation and Maintain ==
398
399 === 2.6.1 Before measurement ===
400
401 (((
402 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
403 )))
404
405
406
407 === 2.6.2 Measurement ===
408
409
410 (% style="color:#4f81bd" %)**Measurement the soil surface:**
411
412 [[image:1654592946732-634.png]]
413
414 Choose the proper measuring position. Split the surface soil according to the measured deep.
415
416 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
417
418 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
419
420 Put soil over the probe after insert. And start to measure.
421
422
423 (% style="color:#4f81bd" %)**Measurement inside soil:**
424
425 Dig a hole with diameter > 20CM.
426
427 Insert the probe inside, method like measure the surface.
428
429
430
431 === 2.6.3 Maintain Probe ===
432
433 1. (((
434 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
435 )))
436 1. (((
437 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
438 )))
439 1. (((
440 Probe reference electrode is also no strong, need to avoid strong force or hitting.
441 )))
442 1. (((
443 User should keep reference electrode wet while not use.
444 )))
445 1. (((
446 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
447 )))
448 1. (((
449 The probe is IP68 can be put in water.
450
451
452
453 )))
454
455 == 2.7 Calibration ==
456
457 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
458
459 After stable, user can use below command to calibrate.
460
461 [[image:image-20220607171149-4.png]]
462
463
464 (% style="color:#037691" %)**Calibration Payload**
465
466 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
467 |(((
468 **Size**
469
470 **(bytes)**
471 )))|**1**|**1**|**1**|**7**|**1**
472 |**Value**|(((
473 PH4
474
475 Calibrate value
476 )))|PH6.86 Calibrate value|(((
477 PH9.18
478
479 Calibrate value
480 )))|Reserve|(((
481 [[Message Type>>path:#H2.3.6MessageType]]
482
483 Always 0x03
484 )))
485
486 User can also send 0x14 downlink command to poll the current calibration payload.
487
488 [[image:image-20220607171416-7.jpeg]]
489
490
491 * Reply to the confirmation package: 14 01
492 * Reply to non-confirmed packet: 14 00
493
494 == 2.8 Frequency Plans ==
495
496 (((
497 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
498 )))
499
500
501 === 2.8.1 EU863-870 (EU868) ===
502
503 (% style="color:blue" %)**Uplink:**
504
505 868.1 - SF7BW125 to SF12BW125
506
507 868.3 - SF7BW125 to SF12BW125 and SF7BW250
508
509 868.5 - SF7BW125 to SF12BW125
510
511 867.1 - SF7BW125 to SF12BW125
512
513 867.3 - SF7BW125 to SF12BW125
514
515 867.5 - SF7BW125 to SF12BW125
516
517 867.7 - SF7BW125 to SF12BW125
518
519 867.9 - SF7BW125 to SF12BW125
520
521 868.8 - FSK
522
523
524 (% style="color:blue" %)**Downlink:**
525
526 Uplink channels 1-9 (RX1)
527
528 869.525 - SF9BW125 (RX2 downlink only)
529
530
531
532 === 2.8.2 US902-928(US915) ===
533
534 (((
535 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
536 )))
537
538 (((
539 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
540 )))
541
542 (((
543 After Join success, the end node will switch to the correct sub band by:
544 )))
545
546 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
547 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
548
549
550 === 2.8.3 CN470-510 (CN470) ===
551
552 Used in China, Default use CHE=1
553
554 (% style="color:blue" %)**Uplink:**
555
556 486.3 - SF7BW125 to SF12BW125
557
558 486.5 - SF7BW125 to SF12BW125
559
560 486.7 - SF7BW125 to SF12BW125
561
562 486.9 - SF7BW125 to SF12BW125
563
564 487.1 - SF7BW125 to SF12BW125
565
566 487.3 - SF7BW125 to SF12BW125
567
568 487.5 - SF7BW125 to SF12BW125
569
570 487.7 - SF7BW125 to SF12BW125
571
572
573 (% style="color:blue" %)**Downlink:**
574
575 506.7 - SF7BW125 to SF12BW125
576
577 506.9 - SF7BW125 to SF12BW125
578
579 507.1 - SF7BW125 to SF12BW125
580
581 507.3 - SF7BW125 to SF12BW125
582
583 507.5 - SF7BW125 to SF12BW125
584
585 507.7 - SF7BW125 to SF12BW125
586
587 507.9 - SF7BW125 to SF12BW125
588
589 508.1 - SF7BW125 to SF12BW125
590
591 505.3 - SF12BW125 (RX2 downlink only)
592
593
594
595 === 2.8.4 AU915-928(AU915) ===
596
597 (((
598 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
599 )))
600
601 (((
602 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
603 )))
604
605 (((
606
607 )))
608
609 (((
610 After Join success, the end node will switch to the correct sub band by:
611 )))
612
613 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
614 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
615
616
617 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
618
619 (% style="color:blue" %)**Default Uplink channel:**
620
621 923.2 - SF7BW125 to SF10BW125
622
623 923.4 - SF7BW125 to SF10BW125
624
625
626 (% style="color:blue" %)**Additional Uplink Channel**:
627
628 (OTAA mode, channel added by JoinAccept message)
629
630
631 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
632
633 922.2 - SF7BW125 to SF10BW125
634
635 922.4 - SF7BW125 to SF10BW125
636
637 922.6 - SF7BW125 to SF10BW125
638
639 922.8 - SF7BW125 to SF10BW125
640
641 923.0 - SF7BW125 to SF10BW125
642
643 922.0 - SF7BW125 to SF10BW125
644
645
646 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
647
648 923.6 - SF7BW125 to SF10BW125
649
650 923.8 - SF7BW125 to SF10BW125
651
652 924.0 - SF7BW125 to SF10BW125
653
654 924.2 - SF7BW125 to SF10BW125
655
656 924.4 - SF7BW125 to SF10BW125
657
658 924.6 - SF7BW125 to SF10BW125
659
660
661 (% style="color:blue" %)**Downlink:**
662
663 Uplink channels 1-8 (RX1)
664
665 923.2 - SF10BW125 (RX2)
666
667
668
669 === 2.8.6 KR920-923 (KR920) ===
670
671 (% style="color:blue" %)**Default channel:**
672
673 922.1 - SF7BW125 to SF12BW125
674
675 922.3 - SF7BW125 to SF12BW125
676
677 922.5 - SF7BW125 to SF12BW125
678
679
680 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
681
682 922.1 - SF7BW125 to SF12BW125
683
684 922.3 - SF7BW125 to SF12BW125
685
686 922.5 - SF7BW125 to SF12BW125
687
688 922.7 - SF7BW125 to SF12BW125
689
690 922.9 - SF7BW125 to SF12BW125
691
692 923.1 - SF7BW125 to SF12BW125
693
694 923.3 - SF7BW125 to SF12BW125
695
696
697 (% style="color:blue" %)**Downlink:**
698
699 Uplink channels 1-7(RX1)
700
701 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
702
703
704
705 === 2.8.7 IN865-867 (IN865) ===
706
707 (% style="color:blue" %)**Uplink:**
708
709 865.0625 - SF7BW125 to SF12BW125
710
711 865.4025 - SF7BW125 to SF12BW125
712
713 865.9850 - SF7BW125 to SF12BW125
714
715
716 (% style="color:blue" %)**Downlink:**
717
718 Uplink channels 1-3 (RX1)
719
720 866.550 - SF10BW125 (RX2)
721
722
723
724 == 2.9 LED Indicator ==
725
726 The LSPH01 has an internal LED which is to show the status of different state.
727
728 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
729 * Blink once when device transmit a packet.
730
731
732 == 2.10 ​Firmware Change Log ==
733
734
735 **Firmware download link:**
736
737 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
738
739
740 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>path:/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]]
741
742
743
744 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
745
746 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
747
748 * AT Command Connection: See [[FAQ>>path:#H6.FAQ]].
749 * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]]
750
751 There are two kinds of commands to configure LSPH01, they are:
752
753 * (% style="color:#4f81bd" %)** General Commands**.
754
755 These commands are to configure:
756
757 * General system settings like: uplink interval.
758 * LoRaWAN protocol & radio related command.
759
760 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
761
762
763 * (% style="color:#4f81bd" %)** Commands special design for LSPH01**
764
765 These commands only valid for LSPH01, as below:
766
767
768
769 == 3.1 Set Transmit Interval Time ==
770
771 Feature: Change LoRaWAN End Node Transmit Interval.
772
773 (% style="color:#037691" %)**AT Command: AT+TDC**
774
775 [[image:image-20220607171554-8.png]]
776
777
778
779 (% style="color:#037691" %)**Downlink Command: 0x01**
780
781 Format: Command Code (0x01) followed by 3 bytes time value.
782
783 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
784
785 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
786 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
787
788 == 3.2 Set Interrupt Mode ==
789
790 Feature, Set Interrupt mode for GPIO_EXIT.
791
792 (% style="color:#037691" %)**AT Command: AT+INTMOD**
793
794 [[image:image-20220607171716-9.png]]
795
796
797 (% style="color:#037691" %)**Downlink Command: 0x06**
798
799 Format: Command Code (0x06) followed by 3 bytes.
800
801 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
802
803 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
804 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
805
806
807 == 3.3 Calibrate Sensor ==
808
809 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands
810
811
812
813 == 3.4 Get Firmware Version Info ==
814
815 Feature: use downlink to get firmware version.
816
817 (% style="color:#037691" %)**Downlink Command: 0x26**
818
819 [[image:image-20220607171917-10.png]]
820
821 * Reply to the confirmation package: 26 01
822 * Reply to non-confirmed packet: 26 00
823
824 Device will send an uplink after got this downlink command. With below payload:
825
826 Configures info payload:
827
828 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
829 |=(((
830 **Size(bytes)**
831 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
832 |**Value**|Software Type|(((
833 Frequency
834
835 Band
836 )))|Sub-band|(((
837 Firmware
838
839 Version
840 )))|Sensor Type|Reserve|(((
841 [[Message Type>>path:#H2.3.6MessageType]]
842 Always 0x02
843 )))
844
845 **Software Type**: Always 0x03 for LSPH01
846
847
848 **Frequency Band**:
849
850 *0x01: EU868
851
852 *0x02: US915
853
854 *0x03: IN865
855
856 *0x04: AU915
857
858 *0x05: KZ865
859
860 *0x06: RU864
861
862 *0x07: AS923
863
864 *0x08: AS923-1
865
866 *0x09: AS923-2
867
868 *0xa0: AS923-3
869
870
871 **Sub-Band**: value 0x00 ~~ 0x08
872
873
874 **Firmware Version**: 0x0100, Means: v1.0.0 version
875
876
877 **Sensor Type**:
878
879 0x01: LSE01
880
881 0x02: LDDS75
882
883 0x03: LDDS20
884
885 0x04: LLMS01
886
887 0x05: LSPH01
888
889 0x06: LSNPK01
890
891 0x07: LDDS12
892
893
894
895 = 4. Battery & How to replace =
896
897 == 4.1 Battery Type ==
898
899 (((
900 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
901 )))
902
903 (((
904 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
905 )))
906
907 [[image:1654593587246-335.png]]
908
909
910 Minimum Working Voltage for the LSPH01:
911
912 LSPH01:  2.45v ~~ 3.6v
913
914
915
916 == 4.2 Replace Battery ==
917
918 (((
919 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
920 )))
921
922 (((
923 And make sure the positive and negative pins match.
924 )))
925
926
927
928 == 4.3 Power Consumption Analyze ==
929
930 (((
931 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
932 )))
933
934 (((
935 Instruction to use as below:
936 )))
937
938
939 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
940
941 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
942
943
944 **Step 2**: Open it and choose
945
946 * Product Model
947 * Uplink Interval
948 * Working Mode
949
950 And the Life expectation in difference case will be shown on the right.
951
952 [[image:1654593605679-189.png]]
953
954
955 The battery related documents as below:
956
957 * (((
958 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
959 )))
960 * (((
961 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
962 )))
963 * (((
964 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
965 )))
966
967 [[image:image-20220607172042-11.png]]
968
969
970
971 === 4.3.1 ​Battery Note ===
972
973 (((
974 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
975 )))
976
977
978
979 === ​4.3.2 Replace the battery ===
980
981 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
982
983 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
984
985
986
987 = 5. Use AT Command =
988
989 == 5.1 Access AT Commands ==
990
991 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
992
993 [[image:1654593668970-604.png]]
994
995 **Connection:**
996
997 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
998
999 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
1000
1001 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
1002
1003
1004 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1005
1006
1007 [[image:1654593712276-618.png]]
1008
1009 Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]].
1010
1011
1012
1013 = 6. FAQ =
1014
1015 == 6.1 How to change the LoRa Frequency Bands/Region ==
1016
1017 You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]].
1018 When downloading the images, choose the required image file for download. ​
1019
1020
1021
1022 = 7. Trouble Shooting =
1023
1024 == 7.1 AT Commands input doesn’t work ==
1025
1026 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1027
1028
1029
1030 = 8. Order Info =
1031
1032 Part Number: (% style="color:blue" %)**LSPH01-XX**
1033
1034
1035 (% style="color:blue" %)**XX**(%%): The default frequency band
1036
1037 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
1038 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
1039 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
1040 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1041 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1042 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1043 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
1044 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1045
1046
1047 = 9. ​Packing Info =
1048
1049
1050 **Package Includes**:
1051
1052 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1053
1054 **Dimension and weight**:
1055
1056 * Device Size: cm
1057 * Device Weight: g
1058 * Package Size / pcs : cm
1059 * Weight / pcs : g
1060
1061
1062 = 10. ​Support =
1063
1064 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1065 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].