Version 34.34 by Xiaoling on 2022/06/07 16:47

Hide last authors
Xiaoling 2.2 1 (% style="text-align:center" %)
2 [[image:1654574317295-380.png||height="621" width="576"]]
Xiaoling 1.1 3
4
5
6
7
Xiaoling 14.8 8 **Contents:**
Xiaoling 1.1 9
Xiaoling 14.8 10 {{toc/}}
Xiaoling 1.1 11
12
13
14
15
16
17
18
19
Xiaoling 14.8 20
21
22
Xiaoling 3.2 23 = 1. Introduction =
Xiaoling 2.2 24
Xiaoling 3.2 25 == 1.1 ​What is LoRaWAN Soil pH Sensor ==
Xiaoling 2.2 26
Xiaoling 3.2 27 The Dragino LSPH01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil pH Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof.
Xiaoling 2.2 28
Xiaoling 3.2 29 LSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** (% style="color:#4f81bd" %)pH (%%)**with high accuracy and stable value. The LSPH01 probe can be buried into soil for long time use.
Xiaoling 2.2 30
31 The LoRa wireless technology used in LSPH01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
32
Xiaoling 3.2 33 LSPH01 is powered by (% style="color:#4f81bd" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
Xiaoling 2.2 34
Xiaoling 3.2 35 Each LSPH01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
Xiaoling 2.2 36
37
Xiaoling 3.2 38 [[image:1654580186518-415.png]]
Xiaoling 2.2 39
40
41
Xiaoling 3.2 42 == ​1.2 Features ==
43
Xiaoling 2.2 44 * LoRaWAN 1.0.3 Class A
45 * Ultra-low power consumption
46 * Monitor soil pH with temperature compensation.
47 * Monitor soil temperature
48 * Monitor Battery Level
49 * Support pH calibration by end user
50 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
51 * AT Commands to change parameters
52 * Uplink on periodically
53 * Downlink to change configure
54 * IP66 Waterproof Enclosure
55 * IP68 rate for the Sensor Probe
56 * 8500mAh Battery for long term use
57
Xiaoling 3.3 58 == 1.3 Probe Specification ==
Xiaoling 2.2 59
60
Xiaoling 3.3 61 (% style="color:#4f81bd" %)**Soil pH:**
62
63 * Range: 3 ~~ 10 pH
64 * Resolution: 0.01 pH
65 * Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen)
66 * Temperature Compensation Range: 0 ~~ 50℃
Xiaoling 2.2 67 * IP68 Protection
68 * Length: 3.5 meters
69
Xiaoling 3.3 70 (% style="color:#4f81bd" %)**Soil Temperature:**
Xiaoling 2.2 71
Xiaoling 3.3 72 * Range -40℃~85℃
73 * Resolution: 0.1℃
74 * Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others)
Xiaoling 2.2 75 * IP68 Protection
76 * Length: 3.5 meters
77
Xiaoling 3.3 78 == 1.4 ​Applications ==
79
Xiaoling 2.2 80 * Smart Agriculture
81
Xiaoling 3.3 82 == 1.5 Pin mapping and power on ==
83
Xiaoling 5.5 84 [[image:1654580482666-473.png]]
Xiaoling 2.2 85
86
87
Xiaoling 5.2 88 = 2. Configure LSPH01 to connect to LoRaWAN network =
Xiaoling 2.2 89
Xiaoling 5.5 90 == 2.1 How it works ==
Xiaoling 2.2 91
Xiaoling 5.3 92 (((
Xiaoling 2.2 93 The LSPH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
Xiaoling 5.3 94 )))
Xiaoling 2.2 95
Xiaoling 5.3 96 (((
Xiaoling 34.18 97 In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.
Xiaoling 5.3 98 )))
Xiaoling 2.2 99
100
Xiaoling 5.3 101 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
Xiaoling 2.2 102
Xiaoling 6.3 103 (((
Xiaoling 2.2 104 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example.
Xiaoling 6.3 105 )))
Xiaoling 2.2 106
Xiaoling 6.3 107 (((
108
109 )))
Xiaoling 2.2 110
Xiaoling 6.3 111 (((
Xiaoling 2.2 112 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
Xiaoling 6.3 113 )))
Xiaoling 2.2 114
Xiaoling 6.3 115 (((
Xiaoling 23.5 116 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.
Xiaoling 6.3 117 )))
Xiaoling 2.2 118
Xiaoling 6.3 119 (((
Xiaoling 2.2 120 Each LSPH01 is shipped with a sticker with the default device EUI as below:
Xiaoling 6.3 121 )))
Xiaoling 2.2 122
123
Xiaoling 6.3 124 [[image:image-20220607135531-1.jpeg]]
Xiaoling 2.2 125
126
127 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
128
129
130 **Register the device**
131
Xiaoling 9.2 132 [[image:1654581442672-605.png]]
Xiaoling 2.2 133
134
Xiaoling 9.2 135
Xiaoling 2.2 136 **Add APP EUI and DEV EUI**
137
Xiaoling 9.2 138 [[image:1654581465717-368.png]]
Xiaoling 2.2 139
140
141
142 **Add APP EUI in the application**
143
Xiaoling 9.2 144 [[image:1654581493871-516.png]]
Xiaoling 2.2 145
146
Xiaoling 10.2 147
Xiaoling 2.2 148 **Add APP KEY**
149
Xiaoling 10.2 150 [[image:1654581517630-991.png]]
Xiaoling 2.2 151
152
Xiaoling 23.5 153 (% style="color:blue" %)**Step 2**(%%): Power on LSPH01
Xiaoling 2.2 154
155
156 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position).
157
Xiaoling 11.2 158 [[image:image-20220607135918-2.png]]
Xiaoling 2.2 159
160
Xiaoling 23.5 161 (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
Xiaoling 2.2 162
Xiaoling 12.2 163 [[image:1654581590132-631.png]]
Xiaoling 2.2 164
165
166
Xiaoling 13.2 167 == 2.3 ​Uplink Payload ==
Xiaoling 2.2 168
Xiaoling 3.2 169 LSPH01 will uplink payload via LoRaWAN with below payload format: 
Xiaoling 2.2 170
171 Uplink payload includes in total 11 bytes.
172
173 Normal uplink payload:
174
Xiaoling 13.2 175 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
Xiaoling 2.2 176 |(((
177 **Size**
178
179 **(bytes)**
180 )))|**2**|**2**|**2**|**2**|**1**|**1**|**1**
Xiaoling 14.5 181 |**Value**|[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(((
Xiaoling 14.6 182 [[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
Xiaoling 2.2 183
Xiaoling 14.6 184 [[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]]
185 )))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|(((
186 [[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]]
Xiaoling 2.2 187 )))|Reserve|(((
Xiaoling 14.6 188 [[Message Type>>||anchor="H2.3.6MessageType"]]
Xiaoling 2.2 189 )))
190
Xiaoling 13.2 191 [[image:1654581735133-458.png]]
Xiaoling 2.2 192
193
194
Xiaoling 13.2 195 === 2.3.1 Battery Info ===
Xiaoling 2.2 196
Xiaoling 13.2 197
Xiaoling 2.2 198 Check the battery voltage for LSPH01.
199
200 Ex1: 0x0B45 = 2885mV
201
202 Ex2: 0x0B49 = 2889mV
203
204
205
Xiaoling 13.2 206 === 2.3.2 DS18B20 Temperature sensor ===
Xiaoling 2.2 207
Xiaoling 13.2 208 This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
Xiaoling 2.2 209
Xiaoling 13.2 210
Xiaoling 2.2 211 **Example**:
212
213 If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
214
215 If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
216
217
218
Xiaoling 13.3 219 === 2.3.3 Soil pH ===
Xiaoling 2.2 220
221 Range: 0 ~~ 14 pH
222
Xiaoling 13.3 223 **Example:**
Xiaoling 2.2 224
Xiaoling 13.3 225 (% style="color:#037691" %)** 0x02B7(H) = 695(D) = 6.95pH**
Xiaoling 2.2 226
227
228
Xiaoling 13.3 229 === 2.3.4 Soil Temperature ===
230
Xiaoling 2.2 231 Get Soil Temperature 
232
233
234 **Example**:
235
Xiaoling 13.3 236 If payload is: **0105H**:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
Xiaoling 2.2 237
Xiaoling 13.3 238 If payload is: **FF3FH** :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
Xiaoling 2.2 239
240
241
Xiaoling 13.3 242 === 2.3.5 Interrupt Pin ===
Xiaoling 2.2 243
Xiaoling 13.4 244 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.
Xiaoling 2.2 245
246
Xiaoling 13.3 247 **Example:**
Xiaoling 2.2 248
249 0x00: Normal uplink packet.
250
251 0x01: Interrupt Uplink Packet.
252
253
254
Xiaoling 13.3 255 === 2.3.6 Message Type ===
256
Xiaoling 2.2 257 For a normal uplink payload, the message type is always 0x01.
258
259 Valid Message Type:
260
261
Xiaoling 13.4 262 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
263 |**Message Type Code**|**Description**|**Payload**
Xiaoling 34.21 264 |0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]
Xiaoling 13.5 265 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]
Xiaoling 13.6 266 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]]
Xiaoling 2.2 267
Xiaoling 13.6 268 === 2.3.7 Decode payload in The Things Network ===
269
Xiaoling 2.2 270 While using TTN network, you can add the payload format to decode the payload.
271
272
Xiaoling 14.2 273 [[image:1654582541848-906.png]]
Xiaoling 2.2 274
Xiaoling 14.2 275 (((
Xiaoling 2.2 276 The payload decoder function for TTN is here:
Xiaoling 14.2 277 )))
Xiaoling 2.2 278
Xiaoling 14.2 279 (((
Xiaoling 2.2 280 LSPH01 TTN Payload Decoder: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
Xiaoling 14.2 281 )))
Xiaoling 2.2 282
283
284
Xiaoling 14.3 285 == 2.4 Uplink Interval ==
286
Xiaoling 14.4 287 The LSPH01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
Xiaoling 2.2 288
289
290
Xiaoling 16.2 291 == 2.5 ​Show Data in DataCake IoT Server ==
Xiaoling 2.2 292
293 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
294
295
Xiaoling 23.5 296 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**
Xiaoling 2.2 297
Xiaoling 23.5 298 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**
Xiaoling 2.2 299
300
Xiaoling 16.2 301 [[image:1654583683416-869.png]]
Xiaoling 2.2 302
303
Xiaoling 16.2 304 [[image:1654583694084-878.png]]
Xiaoling 2.2 305
306
Xiaoling 23.5 307 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**
Xiaoling 2.2 308
Xiaoling 23.5 309 (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**
Xiaoling 2.2 310
Xiaoling 17.2 311 [[image:1654583711590-413.png]]
Xiaoling 2.2 312
313
314
Xiaoling 19.2 315 [[image:1654583732798-193.png]]
Xiaoling 2.2 316
317
Xiaoling 19.2 318 [[image:1654583749683-259.png]]
Xiaoling 2.2 319
320
Xiaoling 23.5 321 (% style="color:blue" %)**Step 5**(%%)**: add payload decode**
Xiaoling 2.2 322
323 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]]
324
325
Xiaoling 23.2 326 [[image:1654583770974-935.png]]
Xiaoling 2.2 327
Xiaoling 23.2 328 [[image:1654583781517-146.png]]
Xiaoling 2.2 329
330
Xiaoling 23.2 331 [[image:1654583791351-557.png]]
Xiaoling 2.2 332
333
334 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
335
336
Xiaoling 23.2 337 [[image:1654583805491-713.png]]
Xiaoling 2.2 338
339
340
Xiaoling 24.2 341 == 2.6 Installation and Maintain ==
Xiaoling 2.2 342
Xiaoling 24.2 343 === 2.6.1 Before measurement ===
344
345 (((
Xiaoling 3.2 346 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 
Xiaoling 24.2 347 )))
Xiaoling 2.2 348
349
350
Xiaoling 24.2 351 === 2.6.2 Measurement ===
Xiaoling 2.2 352
353
Xiaoling 24.2 354 (% style="color:#4f81bd" %)**Measurement the soil surface:**
Xiaoling 2.2 355
Xiaoling 24.2 356 [[image:1654584128046-287.png]]
Xiaoling 2.2 357
Xiaoling 24.2 358 Choose the proper measuring position. Split the surface soil according to the measured deep.
359
Xiaoling 2.2 360 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things.
361
362 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting.
363
364 Put soil over the probe after insert. And start to measure.
365
366
Xiaoling 24.2 367 (% style="color:#4f81bd" %)**Measurement inside soil:**
Xiaoling 2.2 368
Xiaoling 24.2 369 Dig a hole with diameter > 20CM.
Xiaoling 2.2 370
Xiaoling 24.2 371 Insert the probe inside, method like measure the surface.
Xiaoling 2.2 372
373
374
Xiaoling 24.2 375 === 2.6.3 Maintain Probe ===
Xiaoling 2.2 376
Xiaoling 24.2 377 1. (((
378 pH probe electrode is fragile and no strong. User must avoid strong force or hitting it.
379 )))
380 1. (((
381 After long time use (3~~ 6  months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it.
382 )))
383 1. (((
384 Probe reference electrode is also no strong, need to avoid strong force or hitting.
385 )))
386 1. (((
387 User should keep reference electrode wet while not use.
388 )))
389 1. (((
390 Avoid the probes to touch oily matter. Which will cause issue in accuracy.
391 )))
392 1. (((
393 The probe is IP68 can be put in water.
Xiaoling 2.2 394
395
Xiaoling 25.2 396
397 )))
Xiaoling 2.2 398
Xiaoling 24.3 399 == 2.7 Calibration ==
Xiaoling 24.2 400
Xiaoling 2.2 401 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable).
402
Xiaoling 26.2 403 After stable, user can use below command to calibrate.
Xiaoling 2.2 404
Xiaoling 25.2 405 [[image:image-20220607144936-3.png]]
Xiaoling 2.2 406
407
Xiaoling 25.2 408 (% style="color:#037691" %)**Calibration Payload**
Xiaoling 2.2 409
Xiaoling 25.2 410 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
Xiaoling 2.2 411 |(((
412 **Size**
413
414 **(bytes)**
415 )))|**1**|**1**|**1**|**7**|**1**
416 |**Value**|(((
417 PH4
418
419 Calibrate value
420 )))|PH6.86 Calibrate value|(((
421 PH9.18
422
423 Calibrate value
424 )))|Reserve|(((
Xiaoling 25.3 425 [[Message Type>>||anchor="H2.3.6MessageType"]]
426
427 Always 0x03
Xiaoling 2.2 428 )))
429
430 User can also send 0x14 downlink command to poll the current calibration payload.
431
Xiaoling 26.2 432 [[image:image-20220607145603-4.png]]
Xiaoling 2.2 433
434 * Reply to the confirmation package: 14 01
435 * Reply to non-confirmed packet: 14 00
436
Xiaoling 26.5 437 == 2.8 Frequency Plans ==
Xiaoling 26.2 438
Xiaoling 26.6 439 (((
Xiaoling 2.2 440 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
Xiaoling 26.6 441 )))
Xiaoling 2.2 442
443
Xiaoling 26.5 444 === 2.8.1 EU863-870 (EU868) ===
Xiaoling 2.2 445
Xiaoling 26.5 446 (% style="color:blue" %)**Uplink:**
447
Xiaoling 2.2 448 868.1 - SF7BW125 to SF12BW125
449
450 868.3 - SF7BW125 to SF12BW125 and SF7BW250
451
452 868.5 - SF7BW125 to SF12BW125
453
454 867.1 - SF7BW125 to SF12BW125
455
456 867.3 - SF7BW125 to SF12BW125
457
458 867.5 - SF7BW125 to SF12BW125
459
460 867.7 - SF7BW125 to SF12BW125
461
462 867.9 - SF7BW125 to SF12BW125
463
464 868.8 - FSK
465
466
Xiaoling 26.5 467 (% style="color:blue" %)**Downlink:**
Xiaoling 2.2 468
469 Uplink channels 1-9 (RX1)
470
471 869.525 - SF9BW125 (RX2 downlink only)
472
473
474
Xiaoling 26.5 475 === 2.8.2 US902-928(US915) ===
476
477 (((
Xiaoling 2.2 478 Used in USA, Canada and South America. Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
Xiaoling 26.5 479 )))
Xiaoling 2.2 480
Xiaoling 26.5 481 (((
Xiaoling 2.2 482 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
Xiaoling 26.5 483 )))
Xiaoling 2.2 484
Xiaoling 26.5 485 (((
Xiaoling 2.2 486 After Join success, the end node will switch to the correct sub band by:
Xiaoling 26.5 487 )))
Xiaoling 2.2 488
489 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
490 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
491
Xiaoling 26.5 492 === 2.8.3 CN470-510 (CN470) ===
493
Xiaoling 2.2 494 Used in China, Default use CHE=1
495
Xiaoling 26.5 496 (% style="color:blue" %)**Uplink:**
Xiaoling 2.2 497
498 486.3 - SF7BW125 to SF12BW125
499
500 486.5 - SF7BW125 to SF12BW125
501
502 486.7 - SF7BW125 to SF12BW125
503
504 486.9 - SF7BW125 to SF12BW125
505
506 487.1 - SF7BW125 to SF12BW125
507
508 487.3 - SF7BW125 to SF12BW125
509
510 487.5 - SF7BW125 to SF12BW125
511
512 487.7 - SF7BW125 to SF12BW125
513
514
Xiaoling 26.5 515 (% style="color:blue" %)**Downlink:**
Xiaoling 2.2 516
517 506.7 - SF7BW125 to SF12BW125
518
519 506.9 - SF7BW125 to SF12BW125
520
521 507.1 - SF7BW125 to SF12BW125
522
523 507.3 - SF7BW125 to SF12BW125
524
525 507.5 - SF7BW125 to SF12BW125
526
527 507.7 - SF7BW125 to SF12BW125
528
529 507.9 - SF7BW125 to SF12BW125
530
531 508.1 - SF7BW125 to SF12BW125
532
533 505.3 - SF12BW125 (RX2 downlink only)
534
535
536
Xiaoling 26.5 537 === 2.8.4 AU915-928(AU915) ===
538
539 (((
Xiaoling 2.2 540 Frequency band as per definition in LoRaWAN 1.0.3 Regional document.
Xiaoling 26.5 541 )))
Xiaoling 2.2 542
Xiaoling 26.5 543 (((
Xiaoling 2.2 544 To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join.
Xiaoling 26.5 545 )))
Xiaoling 2.2 546
Xiaoling 26.5 547 (((
548
549 )))
Xiaoling 2.2 550
Xiaoling 26.5 551 (((
Xiaoling 2.2 552 After Join success, the end node will switch to the correct sub band by:
Xiaoling 26.5 553 )))
Xiaoling 2.2 554
555 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
556 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
557
Xiaoling 26.5 558 === 2.8.5 AS920-923 & AS923-925 (AS923) ===
559
Xiaoling 26.7 560 (% style="color:blue" %)**Default Uplink channel:**
Xiaoling 2.2 561
562 923.2 - SF7BW125 to SF10BW125
563
564 923.4 - SF7BW125 to SF10BW125
565
566
Xiaoling 26.7 567 (% style="color:blue" %)**Additional Uplink Channel**:
Xiaoling 2.2 568
569 (OTAA mode, channel added by JoinAccept message)
570
571
Xiaoling 26.7 572 (% style="color:blue" %)**AS920~~AS923 for Japan, Malaysia, Singapore**:
573
Xiaoling 2.2 574 922.2 - SF7BW125 to SF10BW125
575
576 922.4 - SF7BW125 to SF10BW125
577
578 922.6 - SF7BW125 to SF10BW125
579
580 922.8 - SF7BW125 to SF10BW125
581
582 923.0 - SF7BW125 to SF10BW125
583
584 922.0 - SF7BW125 to SF10BW125
585
586
Xiaoling 26.7 587 (% style="color:blue" %)**AS923 ~~ AS925 for Brunei, Cambodia, Hong Kong, Indonesia, Laos, Taiwan, Thailand, Vietnam**:
Xiaoling 2.2 588
589 923.6 - SF7BW125 to SF10BW125
590
591 923.8 - SF7BW125 to SF10BW125
592
593 924.0 - SF7BW125 to SF10BW125
594
595 924.2 - SF7BW125 to SF10BW125
596
597 924.4 - SF7BW125 to SF10BW125
598
599 924.6 - SF7BW125 to SF10BW125
600
601
Xiaoling 26.7 602 (% style="color:blue" %)**Downlink:**
Xiaoling 2.2 603
604 Uplink channels 1-8 (RX1)
605
606 923.2 - SF10BW125 (RX2)
607
608
609
Xiaoling 26.7 610 === 2.8.6 KR920-923 (KR920) ===
Xiaoling 2.2 611
Xiaoling 26.7 612 (% style="color:blue" %)**Default channel:**
613
Xiaoling 2.2 614 922.1 - SF7BW125 to SF12BW125
615
616 922.3 - SF7BW125 to SF12BW125
617
618 922.5 - SF7BW125 to SF12BW125
619
620
Xiaoling 26.7 621 (% style="color:blue" %)**Uplink: (OTAA mode, channel added by JoinAccept message)**
Xiaoling 2.2 622
623 922.1 - SF7BW125 to SF12BW125
624
625 922.3 - SF7BW125 to SF12BW125
626
627 922.5 - SF7BW125 to SF12BW125
628
629 922.7 - SF7BW125 to SF12BW125
630
631 922.9 - SF7BW125 to SF12BW125
632
633 923.1 - SF7BW125 to SF12BW125
634
635 923.3 - SF7BW125 to SF12BW125
636
637
Xiaoling 26.7 638 (% style="color:blue" %)**Downlink:**
Xiaoling 2.2 639
640 Uplink channels 1-7(RX1)
641
642 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
643
644
Xiaoling 26.7 645 === 2.8.7 IN865-867 (IN865) ===
Xiaoling 2.2 646
Xiaoling 26.7 647 (% style="color:blue" %)**Uplink:**
Xiaoling 2.2 648
649 865.0625 - SF7BW125 to SF12BW125
650
651 865.4025 - SF7BW125 to SF12BW125
652
653 865.9850 - SF7BW125 to SF12BW125
654
655
Xiaoling 26.7 656 (% style="color:blue" %)**Downlink:**
Xiaoling 2.2 657
658 Uplink channels 1-3 (RX1)
659
660 866.550 - SF10BW125 (RX2)
661
662
663
Xiaoling 26.7 664 == 2.9 LED Indicator ==
665
Xiaoling 2.2 666 The LSPH01 has an internal LED which is to show the status of different state.
667
668 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
669 * Blink once when device transmit a packet.
670
Xiaoling 26.9 671 == 2.10 ​Firmware Change Log ==
Xiaoling 2.2 672
Xiaoling 26.15 673
Xiaoling 2.2 674 **Firmware download link:**
675
676 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
677
678
Xiaoling 26.14 679 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
Xiaoling 2.2 680
681
682
Xiaoling 26.16 683 = 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
Xiaoling 2.2 684
685 Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
686
Xiaoling 26.17 687 * AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
688 * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
Xiaoling 2.2 689
690 There are two kinds of commands to configure LSPH01, they are:
691
Xiaoling 27.2 692 * (% style="color:#4f81bd" %)** General Commands**.
Xiaoling 2.2 693
694 These commands are to configure:
695
696 * General system settings like: uplink interval.
697 * LoRaWAN protocol & radio related command.
698
Xiaoling 26.17 699 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Xiaoling 2.2 700
701
Xiaoling 27.2 702 * (% style="color:#4f81bd" %)** Commands special design for LSPH01**
Xiaoling 2.2 703
704 These commands only valid for LSPH01, as below:
705
706
707
Xiaoling 27.2 708 == 3.1 Set Transmit Interval Time ==
709
Xiaoling 2.2 710 Feature: Change LoRaWAN End Node Transmit Interval.
711
Xiaoling 27.2 712 (% style="color:#037691" %)**AT Command: AT+TDC**
Xiaoling 2.2 713
Xiaoling 27.2 714
715 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
716 |(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
717 |(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
Xiaoling 2.2 718 30000
719
720 OK
721
722 the interval is 30000ms = 30s
723 )))
Xiaoling 27.2 724 |(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
Xiaoling 2.2 725 OK
726
727 Set transmit interval to 60000ms = 60 seconds
728 )))
729
Xiaoling 27.2 730 (% style="color:#037691" %)**Downlink Command: 0x01**
Xiaoling 2.2 731
732 Format: Command Code (0x01) followed by 3 bytes time value.
733
734 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
735
736 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
737 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
738
Xiaoling 34.26 739
Xiaoling 27.3 740 == 3.2 Set Interrupt Mode ==
741
Xiaoling 2.2 742 Feature, Set Interrupt mode for GPIO_EXIT.
743
Xiaoling 27.3 744 (% style="color:#037691" %)**AT Command: AT+INTMOD**
Xiaoling 2.2 745
Xiaoling 28.2 746 [[image:image-20220607153759-6.png]]
Xiaoling 2.2 747
748
Xiaoling 27.3 749 (% style="color:#037691" %)**Downlink Command: 0x06**
Xiaoling 2.2 750
751 Format: Command Code (0x06) followed by 3 bytes.
752
753 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
754
755 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
756 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
757
Xiaoling 34.27 758
Xiaoling 27.3 759 == 3.3 Calibrate Sensor ==
760
Xiaoling 34.28 761 Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
Xiaoling 2.2 762
763
764
Xiaoling 28.3 765 == 3.4 Get Firmware Version Info ==
766
Xiaoling 2.2 767 Feature: use downlink to get firmware version.
768
Xiaoling 27.3 769 (% style="color:#037691" %)**Downlink Command: 0x26**
Xiaoling 2.2 770
Xiaoling 29.2 771 [[image:image-20220607154718-7.png]]
Xiaoling 2.2 772
773 * Reply to the confirmation package: 26 01
774 * Reply to non-confirmed packet: 26 00
775
776 Device will send an uplink after got this downlink command. With below payload:
777
778 Configures info payload:
779
Xiaoling 29.4 780 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
781 |=(((
782 **Size(bytes)**
783 )))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
Xiaoling 2.2 784 |**Value**|Software Type|(((
785 Frequency
786
787 Band
788 )))|Sub-band|(((
789 Firmware
790
791 Version
792 )))|Sensor Type|Reserve|(((
Xiaoling 29.4 793 [[Message Type>>||anchor="H2.3.6MessageType"]]
Xiaoling 2.2 794 Always 0x02
795 )))
796
797 **Software Type**: Always 0x03 for LSPH01
798
799
800 **Frequency Band**:
801
802 *0x01: EU868
803
804 *0x02: US915
805
806 *0x03: IN865
807
808 *0x04: AU915
809
810 *0x05: KZ865
811
812 *0x06: RU864
813
814 *0x07: AS923
815
816 *0x08: AS923-1
817
818 *0x09: AS923-2
819
820 *0xa0: AS923-3
821
822
823 **Sub-Band**: value 0x00 ~~ 0x08
824
825
826 **Firmware Version**: 0x0100, Means: v1.0.0 version
827
828
829 **Sensor Type**:
830
831 0x01: LSE01
832
833 0x02: LDDS75
834
835 0x03: LDDS20
836
837 0x04: LLMS01
838
839 0x05: LSPH01
840
841 0x06: LSNPK01
842
843 0x07: LDDS12
844
845
846
Xiaoling 29.9 847 = 4. Battery & How to replace =
Xiaoling 2.2 848
Xiaoling 29.9 849 == 4.1 Battery Type ==
Xiaoling 2.2 850
Xiaoling 30.2 851 (((
Xiaoling 2.2 852 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
Xiaoling 30.2 853 )))
Xiaoling 2.2 854
Xiaoling 30.2 855 (((
Xiaoling 2.2 856 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
Xiaoling 30.2 857 )))
Xiaoling 2.2 858
Xiaoling 30.2 859 [[image:1654588469844-778.png]]
Xiaoling 2.2 860
861
862 Minimum Working Voltage for the LSPH01:
863
864 LSPH01:  2.45v ~~ 3.6v
865
866
867
Xiaoling 30.3 868 == 4.2 Replace Battery ==
869
Xiaoling 30.5 870 (((
Xiaoling 2.2 871 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
Xiaoling 30.5 872 )))
Xiaoling 2.2 873
Xiaoling 30.5 874 (((
Xiaoling 2.2 875 And make sure the positive and negative pins match.
Xiaoling 30.5 876 )))
Xiaoling 2.2 877
878
879
Xiaoling 30.4 880 == 4.3 Power Consumption Analyze ==
Xiaoling 2.2 881
Xiaoling 30.5 882 (((
Xiaoling 2.2 883 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
Xiaoling 30.5 884 )))
Xiaoling 2.2 885
Xiaoling 30.5 886 (((
Xiaoling 2.2 887 Instruction to use as below:
Xiaoling 30.5 888 )))
Xiaoling 2.2 889
890
Xiaoling 32.3 891 **Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
Xiaoling 2.2 892
893 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
894
895
Xiaoling 32.3 896 **Step 2**: Open it and choose
Xiaoling 2.2 897
898 * Product Model
899 * Uplink Interval
900 * Working Mode
901
902 And the Life expectation in difference case will be shown on the right.
903
Xiaoling 32.2 904 [[image:1654588577573-122.png]]
Xiaoling 2.2 905
906
907 The battery related documents as below:
908
Xiaoling 32.2 909 * (((
910 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
Xiaoling 2.2 911 )))
Xiaoling 32.2 912 * (((
913 [[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
914 )))
915 * (((
916 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
917 )))
Xiaoling 2.2 918
Xiaoling 32.2 919 [[image:image-20220607155856-8.png]]
Xiaoling 2.2 920
921
922
Xiaoling 32.4 923 === 4.3.1 ​Battery Note ===
Xiaoling 2.2 924
Xiaoling 32.4 925 (((
Xiaoling 2.2 926 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
Xiaoling 32.4 927 )))
Xiaoling 2.2 928
929
930
Xiaoling 32.4 931 === ​4.3.2 Replace the battery ===
932
Xiaoling 2.2 933 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
934
935 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
936
937
938
Xiaoling 33.2 939 = 5. Use AT Command =
Xiaoling 2.2 940
Xiaoling 33.2 941 == 5.1 Access AT Commands ==
Xiaoling 2.2 942
943 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
944
Xiaoling 33.2 945 [[image:1654589001411-343.png]]
Xiaoling 2.2 946
Xiaoling 34.6 947 **Connection:**
Xiaoling 2.2 948
Xiaoling 34.2 949 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
Xiaoling 2.2 950
Xiaoling 34.2 951 (% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
Xiaoling 2.2 952
Xiaoling 34.2 953 (% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
Xiaoling 2.2 954
955
Xiaoling 34.6 956 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
Xiaoling 2.2 957
958
Xiaoling 34.2 959 [[image:1654589062541-567.png]]
Xiaoling 2.2 960
Xiaoling 34.32 961 Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
Xiaoling 2.2 962
963
964
Xiaoling 34.7 965 = 6. FAQ =
Xiaoling 2.2 966
Xiaoling 34.7 967 == 6.1 How to change the LoRa Frequency Bands/Region ==
968
Xiaoling 34.8 969 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
Xiaoling 2.2 970 When downloading the images, choose the required image file for download. ​
971
972
973
Xiaoling 34.7 974 = 7. Trouble Shooting =
Xiaoling 2.2 975
Xiaoling 34.7 976 == 7.1 AT Commands input doesn’t work ==
977
Xiaoling 34.9 978 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
Xiaoling 2.2 979
980
981
Xiaoling 34.9 982 = 8. Order Info =
Xiaoling 2.2 983
Xiaoling 34.9 984 Part Number: (% style="color:blue" %)**LSPH01-XX**
Xiaoling 2.2 985
986
Xiaoling 34.9 987 (% style="color:blue" %)**XX**(%%): The default frequency band
Xiaoling 2.2 988
Xiaoling 34.13 989 * (% style="color:red" %)**AS923**(%%):  LoRaWAN AS923 band
Xiaoling 34.9 990 * (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
991 * (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
992 * (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
993 * (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
994 * (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
Xiaoling 34.13 995 * (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
Xiaoling 34.9 996 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
Xiaoling 2.2 997
Xiaoling 34.33 998
Xiaoling 34.9 999 = 9. ​Packing Info =
1000
1001
Xiaoling 2.2 1002 **Package Includes**:
1003
1004 * LSPH01 LoRaWAN Soil Ph Sensor x 1
1005
1006 **Dimension and weight**:
1007
1008 * Device Size: cm
1009 * Device Weight: g
1010 * Package Size / pcs : cm
1011 * Weight / pcs : g
1012
Xiaoling 34.33 1013
Xiaoling 2.4 1014 = 10. ​Support =
Xiaoling 2.2 1015
1016 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Xiaoling 34.12 1017 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
Xiaoling 2.2 1018
Xiaoling 23.4 1019