Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/03/07 08:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -913,10 +913,10 @@ 913 913 914 914 915 915 916 -= 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =916 += 4. Configure LLDS12 via AT Command or LoRaWAN Downlink = 917 917 918 918 ((( 919 -Use can configure LS PH01 via AT Command or LoRaWAN Downlink.919 +Use can configure LLDS12 via AT Command or LoRaWAN Downlink. 920 920 ))) 921 921 922 922 * ((( ... ... @@ -927,7 +927,9 @@ 927 927 ))) 928 928 929 929 ((( 930 -There are two kinds of commands to configure LSPH01, they are: 930 + 931 + 932 +There are two kinds of commands to configure LLDS12, they are: 931 931 ))) 932 932 933 933 * ((( ... ... @@ -946,7 +946,7 @@ 946 946 ))) 947 947 948 948 ((( 949 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 951 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 950 950 ))) 951 951 952 952 ((( ... ... @@ -954,16 +954,16 @@ 954 954 ))) 955 955 956 956 * ((( 957 -(% style="color:#4f81bd" %)** Commands special design for LS PH01**959 +(% style="color:#4f81bd" %)** Commands special design for LLDS12** 958 958 ))) 959 959 960 960 ((( 961 -These commands only valid for LS PH01, as below:963 +These commands only valid for LLDS12, as below: 962 962 ))) 963 963 964 964 965 965 966 -== 3.1 Set Transmit Interval Time ==968 +== 4.1 Set Transmit Interval Time == 967 967 968 968 Feature: Change LoRaWAN End Node Transmit Interval. 969 969 ... ... @@ -995,7 +995,7 @@ 995 995 996 996 ))) 997 997 998 -== 3.2 Set Interrupt Mode ==1000 +== 4.2 Set Interrupt Mode == 999 999 1000 1000 Feature, Set Interrupt mode for GPIO_EXIT. 1001 1001 ... ... @@ -1023,20 +1023,10 @@ 1023 1023 Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1024 1024 ))) 1025 1025 1026 -((( 1027 - 1028 -))) 1029 1029 1030 1030 1030 +== 4.3 Get Firmware Version Info == 1031 1031 1032 -== 3.3 Calibrate Sensor == 1033 - 1034 -Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1035 - 1036 - 1037 - 1038 -== 3.4 Get Firmware Version Info == 1039 - 1040 1040 Feature: use downlink to get firmware version. 1041 1041 1042 1042 (% style="color:#037691" %)**Downlink Command: 0x26**