Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/03/07 08:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,9 +10,9 @@ 10 10 11 11 12 12 13 -= 1. Introduction = 13 += 1. Introduction = 14 14 15 -== 1.1 What is LoRaWAN LiDAR ToF Distance Sensor == 15 +== 1.1 What is LoRaWAN LiDAR ToF Distance Sensor == 16 16 17 17 ((( 18 18 ... ... @@ -35,9 +35,8 @@ 35 35 36 36 37 37 38 +== 1.2 Features == 38 38 39 -== 1.2 Features == 40 - 41 41 * LoRaWAN 1.0.3 Class A 42 42 * Ultra-low power consumption 43 43 * Laser technology for distance detection ... ... @@ -50,46 +50,55 @@ 50 50 * Downlink to change configure 51 51 * 8500mAh Battery for long term use 52 52 53 -== 1.3 Probe Specification == 52 +== 1.3 Probe Specification == 54 54 54 +* Storage temperature :-20℃~~75℃ 55 +* Operating temperature - -20℃~~60℃ 56 +* Operating Range - 0.1m~~12m① 57 +* Accuracy - ±5cm@(0.1-6m), ±1%@(6m-12m) 58 +* Distance resolution - 5mm 59 +* Ambient light immunity - 70klux 60 +* Enclosure rating - IP65 61 +* Light source - LED 62 +* Central wavelength - 850nm 63 +* FOV - 3.6° 64 +* Material of enclosure - ABS+PC 65 +* Wire length - 25cm 55 55 56 - (% style="color:#4f81bd"%)**SoilpH:**67 +== 1.4 Probe Dimension == 57 57 58 -* Range: 3 ~~ 10 pH 59 -* Resolution: 0.01 pH 60 -* Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen) 61 -* Temperature Compensation Range: 0 ~~ 50℃ 62 -* IP68 Protection 63 -* Length: 3.5 meters 64 64 65 - (% style="color:#4f81bd" %)**Soil Temperature:**70 +[[image:1654827224480-952.png]] 66 66 67 -* Range -40℃~85℃ 68 -* Resolution: 0.1℃ 69 -* Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others) 70 -* IP68 Protection 71 -* Length: 3.5 meters 72 72 73 -== 1.4 Applications == 74 74 75 - *SmartAgriculture74 +== 1.5 Applications == 76 76 77 -== 1.5 Pin mapping and power on == 76 +* Horizontal distance measurement 77 +* Parking management system 78 +* Object proximity and presence detection 79 +* Intelligent trash can management system 80 +* Robot obstacle avoidance 81 +* Automatic control 82 +* Sewer 78 78 79 - [[image:1654592472094-134.png]]84 +== 1.6 Pin mapping and power on == 80 80 81 81 87 +[[image:1654827332142-133.png]] 82 82 83 -= 2. Configure LSPH01 to connect to LoRaWAN network = 84 84 90 + 91 += 2. Configure LLDS12 to connect to LoRaWAN network = 92 + 85 85 == 2.1 How it works == 86 86 87 87 ((( 88 -The LS PH01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSPH01. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.96 +The LLDS12 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LLDS12. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes. 89 89 ))) 90 90 91 91 ((( 92 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H 5.UseATCommand"]]to set the keys in the LSPH01.100 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H6.UseATCommand"]]to set the keys in the LLDS12. 93 93 ))) 94 94 95 95 ... ... @@ -100,7 +100,7 @@ 100 100 ))) 101 101 102 102 ((( 103 -[[image:16545 92492399-921.png]]111 +[[image:1654827857527-556.png]] 104 104 ))) 105 105 106 106 ((( ... ... @@ -477,7 +477,6 @@ 477 477 * Reply to the confirmation package: 14 01 478 478 * Reply to non-confirmed packet: 14 00 479 479 480 - 481 481 == 2.8 Frequency Plans == 482 482 483 483 ((( ... ... @@ -562,7 +562,6 @@ 562 562 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 563 563 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 564 564 565 - 566 566 === 2.8.3 CN470-510 (CN470) === 567 567 568 568 ((( ... ... @@ -907,10 +907,10 @@ 907 907 908 908 909 909 910 -= 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =916 += 4. Configure LLDS12 via AT Command or LoRaWAN Downlink = 911 911 912 912 ((( 913 -Use can configure LS PH01 via AT Command or LoRaWAN Downlink.919 +Use can configure LLDS12 via AT Command or LoRaWAN Downlink. 914 914 ))) 915 915 916 916 * ((( ... ... @@ -921,6 +921,8 @@ 921 921 ))) 922 922 923 923 ((( 930 + 931 + 924 924 There are two kinds of commands to configure LSPH01, they are: 925 925 ))) 926 926 ... ... @@ -1111,12 +1111,12 @@ 1111 1111 1112 1112 1113 1113 1114 -= 4. Battery & How to replace =1122 += 5. Battery & How to replace = 1115 1115 1116 -== 4.1 Battery Type ==1124 +== 5.1 Battery Type == 1117 1117 1118 1118 ((( 1119 -LS PH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.1127 +LLDS12 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1120 1120 ))) 1121 1121 1122 1122 ((( ... ... @@ -1126,13 +1126,13 @@ 1126 1126 [[image:1654593587246-335.png]] 1127 1127 1128 1128 1129 -Minimum Working Voltage for the LS PH01:1137 +Minimum Working Voltage for the LLDS12: 1130 1130 1131 -LS PH01: 2.45v ~~ 3.6v1139 +LLDS12: 2.45v ~~ 3.6v 1132 1132 1133 1133 1134 1134 1135 -== 4.2 Replace Battery ==1143 +== 5.2 Replace Battery == 1136 1136 1137 1137 ((( 1138 1138 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. ... ... @@ -1144,7 +1144,7 @@ 1144 1144 1145 1145 1146 1146 1147 -== 4.3 Power Consumption Analyze ==1155 +== 5.3 Power Consumption Analyze == 1148 1148 1149 1149 ((( 1150 1150 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. ... ... @@ -1187,7 +1187,7 @@ 1187 1187 1188 1188 1189 1189 1190 -=== 4.3.1 Battery Note ===1198 +=== 5.3.1 Battery Note === 1191 1191 1192 1192 ((( 1193 1193 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. ... ... @@ -1195,23 +1195,23 @@ 1195 1195 1196 1196 1197 1197 1198 -=== 4.3.2 Replace the battery ===1206 +=== 5.3.2 Replace the battery === 1199 1199 1200 1200 ((( 1201 -You can change the battery in the LS PH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.1209 +You can change the battery in the LLDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1202 1202 ))) 1203 1203 1204 1204 ((( 1205 -The default battery pack of LS PH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1213 +The default battery pack of LLDS12 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1206 1206 ))) 1207 1207 1208 1208 1209 1209 1210 -= 5. Use AT Command =1218 += 6. Use AT Command = 1211 1211 1212 -== 5.1 Access AT Commands ==1220 +== 6.1 Access AT Commands == 1213 1213 1214 -LS PH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.1222 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1215 1215 1216 1216 [[image:1654593668970-604.png]] 1217 1217 ... ... @@ -1234,27 +1234,53 @@ 1234 1234 Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]]. 1235 1235 1236 1236 1237 -= 6. FAQ =1245 += 7. FAQ = 1238 1238 1239 -== 6.1 How to change the LoRa Frequency Bands/Region ==1247 +== 7.1 How to change the LoRa Frequency Bands/Region == 1240 1240 1241 1241 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1242 1242 When downloading the images, choose the required image file for download. 1243 1243 1244 1244 1245 -= 7. Trouble Shooting =1253 += 8. Trouble Shooting = 1246 1246 1247 -== 7.1 AT Commands input doesn’t work ==1255 +== 8.1 AT Commands input doesn’t work == 1248 1248 1257 + 1249 1249 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1250 1250 1251 1251 1261 +== 8.2 Significant error between the output distant value of LiDAR and actual distance == 1252 1252 1253 -= 8. Order Info = 1254 1254 1255 -Part Number: (% style="color:blue" %)**LSPH01-XX** 1264 +((( 1265 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1266 +))) 1256 1256 1268 +((( 1269 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1270 +))) 1257 1257 1272 +((( 1273 + 1274 +))) 1275 + 1276 +((( 1277 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1278 +))) 1279 + 1280 +((( 1281 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1282 +))) 1283 + 1284 + 1285 + 1286 += 9. Order Info = 1287 + 1288 + 1289 +Part Number: (% style="color:blue" %)**LLDS12-XX** 1290 + 1291 + 1258 1258 (% style="color:blue" %)**XX**(%%): The default frequency band 1259 1259 1260 1260 * (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band ... ... @@ -1266,12 +1266,13 @@ 1266 1266 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1267 1267 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1268 1268 1269 -= 9. Packing Info = 1270 1270 1304 += 10. Packing Info = 1271 1271 1306 + 1272 1272 **Package Includes**: 1273 1273 1274 -* LS PH01 LoRaWANSoilPhSensor x 11309 +* LLDS12 LoRaWAN LiDAR Distance Sensor x 1 1275 1275 1276 1276 **Dimension and weight**: 1277 1277 ... ... @@ -1280,8 +1280,9 @@ 1280 1280 * Package Size / pcs : cm 1281 1281 * Weight / pcs : g 1282 1282 1283 -= 10. Support = 1284 1284 1319 += 11. Support = 1320 + 1285 1285 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1286 1286 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1287 1287
- 1654827224480-952.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.2 KB - Content
- 1654827332142-133.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1654827857527-556.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.3 KB - Content