Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/03/07 08:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,6 +61,8 @@ 61 61 * [[9. Packing Info>>path:#H9.200BPackingInfo]] 62 62 * [[10. Support>>path:#H10.A0200BSupport]] 63 63 64 + 65 + 64 64 = 1. Introduction = 65 65 66 66 == 1.1 What is LoRaWAN Soil pH Sensor == ... ... @@ -90,7 +90,6 @@ 90 90 91 91 92 92 93 - 94 94 == 1.2 Features == 95 95 96 96 * LoRaWAN 1.0.3 Class A ... ... @@ -109,6 +109,7 @@ 109 109 110 110 111 111 113 + 112 112 == 1.3 Probe Specification == 113 113 114 114 ... ... @@ -131,6 +131,7 @@ 131 131 132 132 133 133 136 + 134 134 == 1.4 Applications == 135 135 136 136 * Smart Agriculture ... ... @@ -137,6 +137,7 @@ 137 137 138 138 139 139 143 + 140 140 == 1.5 Pin mapping and power on == 141 141 142 142 [[image:1654592472094-134.png]] ... ... @@ -152,7 +152,7 @@ 152 152 ))) 153 153 154 154 ((( 155 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >> ||anchor="H5.UseATCommand"]]to set the keys in the LSPH01.159 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>path:#H5.UseATCommand]]to set the keys in the LSPH01. 156 156 ))) 157 157 158 158 ... ... @@ -238,17 +238,19 @@ 238 238 ))) 239 239 240 240 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 241 -|=(% style="width: 62.5px;" %)((( 242 -**Size (bytes)** 243 -)))|=(% style="width: 62.5px;" %)**2**|=(% style="width: 62.5px;" %)**2**|=**2**|=**2**|=**1**|=**1**|=**1** 244 -|(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1BatteryInfo"]]|(% style="width:62.5px" %)((( 245 -[[Temperature>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 245 +|((( 246 +**Size** 246 246 247 -[[(Optional)>>||anchor="H2.3.2DS18B20Temperaturesensor"]] 248 -)))|[[Soil pH>>||anchor="H2.3.3SoilpH"]]|[[Soil Temperature>>||anchor="H2.3.4SoilTemperature"]]|((( 249 -[[Digital Interrupt (Optional)>>||anchor="H2.3.5InterruptPin"]] 248 +**(bytes)** 249 +)))|**2**|**2**|**2**|**2**|**1**|**1**|**1** 250 +|**Value**|[[BAT>>path:#H2.3.1BatteryInfo]]|((( 251 +[[Temperature>>path:#H2.3.2DS18B20Temperaturesensor]] 252 + 253 +[[(Optional)>>path:#H2.3.2DS18B20Temperaturesensor]] 254 +)))|[[Soil pH>>path:#H2.3.3SoilpH]]|[[Soil Temperature>>path:#H2.3.4SoilTemperature]]|((( 255 +[[Digital Interrupt (Optional)>>path:#H2.3.5InterruptPin]] 250 250 )))|Reserve|((( 251 -[[Message Type>> ||anchor="H2.3.6MessageType"]]257 +[[Message Type>>path:#H2.3.6MessageType]] 252 252 ))) 253 253 254 254 [[image:1654592721645-318.png]] ... ... @@ -304,7 +304,7 @@ 304 304 305 305 === 2.3.5 Interrupt Pin === 306 306 307 -This data field shows if this packet is generated by interrupt or not. [[Click here>> ||anchor="H3.2SetInterruptMode"]] for the hardware and software set up.313 +This data field shows if this packet is generated by interrupt or not. [[Click here>>path:#H3.2SetInterruptMode]] for the hardware and software set up. 308 308 309 309 310 310 **Example:** ... ... @@ -326,11 +326,11 @@ 326 326 ))) 327 327 328 328 329 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width: 499px" %)330 -|= (% style="width: 160px;" %)**Message Type Code**|=(% style="width: 163px;" %)**Description**|=(% style="width: 173px;" %)**Payload**331 -| (% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3200BUplinkPayload"]]332 -| (% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]]333 -| (% style="width:160px" %)0x03|(% style="width:163px" %)Reply Calibration Info|(% style="width:173px" %)[[Calibration Payload>>||anchor="H2.7Calibration"]]335 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 336 +|=**Message Type Code**|=**Description**|=**Payload** 337 +|0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]] 338 +|0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]] 339 +|0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]] 334 334 335 335 === 2.3.7 Decode payload in The Things Network === 336 336 ... ... @@ -515,9 +515,11 @@ 515 515 (% style="color:#037691" %)**Calibration Payload** 516 516 517 517 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 518 -|=(% style="width: 62.5px;" %)((( 519 -**Size (bytes)** 520 -)))|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**1**|=(% style="width: 89px;" %)**7**|=(% style="width: 89px;" %)**1** 524 +|((( 525 +**Size** 526 + 527 +**(bytes)** 528 +)))|**1**|**1**|**1**|**7**|**1** 521 521 |**Value**|((( 522 522 PH4 523 523 ... ... @@ -527,7 +527,7 @@ 527 527 528 528 Calibrate value 529 529 )))|Reserve|((( 530 -[[Message Type>> ||anchor="H2.3.6MessageType"]]538 +[[Message Type>>path:#H2.3.6MessageType]] 531 531 532 532 Always 0x03 533 533 ))) ... ... @@ -541,6 +541,8 @@ 541 541 * Reply to non-confirmed packet: 14 00 542 542 543 543 552 + 553 + 544 544 == 2.8 Frequency Plans == 545 545 546 546 ((( ... ... @@ -625,6 +625,9 @@ 625 625 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 626 626 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 627 627 638 + 639 + 640 + 628 628 === 2.8.3 CN470-510 (CN470) === 629 629 630 630 ((( ... ... @@ -957,6 +957,9 @@ 957 957 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 958 958 * Blink once when device transmit a packet. 959 959 973 + 974 + 975 + 960 960 == 2.10 Firmware Change Log == 961 961 962 962 ... ... @@ -976,7 +976,7 @@ 976 976 ))) 977 977 978 978 * ((( 979 -AT Command Connection: See [[FAQ>> ||anchor="H6.FAQ"]].995 +AT Command Connection: See [[FAQ>>path:#H6.FAQ]]. 980 980 ))) 981 981 * ((( 982 982 LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>path:/xwiki/bin/view/Main/]] ... ... @@ -1087,7 +1087,7 @@ 1087 1087 1088 1088 == 3.3 Calibrate Sensor == 1089 1089 1090 -Detail See [[Calibration Guide>> ||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands1106 +Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands 1091 1091 1092 1092 1093 1093 ... ... @@ -1119,7 +1119,7 @@ 1119 1119 1120 1120 Version 1121 1121 )))|Sensor Type|Reserve|((( 1122 -[[Message Type>> ||anchor="H2.3.6MessageType"]]1138 +[[Message Type>>path:#H2.3.6MessageType]] 1123 1123 Always 0x02 1124 1124 ))) 1125 1125 ... ... @@ -1293,7 +1293,7 @@ 1293 1293 1294 1294 [[image:1654593712276-618.png]] 1295 1295 1296 -Valid AT Command please check [[Configure Device>> ||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].1312 +Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]. 1297 1297 1298 1298 1299 1299 = 6. FAQ = ... ... @@ -1300,7 +1300,7 @@ 1300 1300 1301 1301 == 6.1 How to change the LoRa Frequency Bands/Region == 1302 1302 1303 -You can follow the instructions for [[how to upgrade image>> ||anchor="H2.10200BFirmwareChangeLog"]].1319 +You can follow the instructions for [[how to upgrade image>>path:#H2.10200BFirmwareChangeLog]]. 1304 1304 When downloading the images, choose the required image file for download. 1305 1305 1306 1306 ... ... @@ -1327,6 +1327,7 @@ 1327 1327 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1328 1328 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1329 1329 1346 + 1330 1330 = 9. Packing Info = 1331 1331 1332 1332 ... ... @@ -1341,6 +1341,7 @@ 1341 1341 * Package Size / pcs : cm 1342 1342 * Weight / pcs : g 1343 1343 1361 + 1344 1344 = 10. Support = 1345 1345 1346 1346 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.