... ... @@ -570,142 +570,106 @@
570 570  
571 571  
572 572  
573 -= 3.  Using the AT Commands =
573 += 3.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
574 574  
575 575  (((
576 576  (((
577 -
577 +Use can configure LDDS75 via AT Command or LoRaWAN Downlink.
578 578  )))
579 579  )))
580 580  
581 -== 3.1  Access AT Commands ==
581 +* (((
582 +(((
583 +AT Command Connection: See [[FAQ>>||anchor="H4.A0FAQ"]].
584 +)))
585 +)))
586 +* (((
587 +(((
588 +LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
589 +)))
590 +)))
582 582  
583 -LDDS20 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS20 for using AT command, as below.
592 +(((
593 +(((
594 +
595 +)))
584 584  
597 +(((
598 +There are two kinds of commands to configure LDDS75, they are:
599 +)))
600 +)))
585 585  
586 -[[image:image-20220610172924-4.png||height="483" width="988"]]
602 +* (((
603 +(((
604 +(% style="color:#4f81bd" %)** General Commands**.
605 +)))
606 +)))
587 587  
608 +(((
609 +(((
610 +These commands are to configure:
611 +)))
612 +)))
588 588  
589 -Or if you have below board, use below connection:
614 +* (((
615 +(((
616 +General system settings like: uplink interval.
617 +)))
618 +)))
619 +* (((
620 +(((
621 +LoRaWAN protocol & radio related command.
622 +)))
623 +)))
590 590  
625 +(((
626 +(((
627 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
628 +)))
629 +)))
591 591  
592 -[[image:image-20220610172924-5.png]]
631 +(((
632 +(((
633 +
634 +)))
635 +)))
593 593  
637 +* (((
638 +(((
639 +(% style="color:#4f81bd" %)** Commands special design for LDDS75**
640 +)))
641 +)))
594 594  
595 595  (((
596 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS20. LDDS20 will output system info once power on as below:
644 +(((
645 +These commands only valid for LDDS75, as below:
597 597  )))
647 +)))
598 598  
599 599  
600 - [[image:image-20220610172924-6.png||height="601" width="860"]]
601 601  
602 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]].
651 +== 3.1  Access AT Commands ==
603 603  
653 +LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below.
604 604  
605 -AT+<CMD>?  :  Help on <CMD>
655 +[[image:image-20220610172924-4.png||height="483" width="988"]]
606 606  
607 -AT+<CMD>  :  Run <CMD>
608 608  
609 -AT+<CMD>=<value>  Set the value
658 +Or if you have below board, use below connection:
610 610  
611 -AT+<CMD>=?  :  Get the value
612 612  
661 +[[image:image-20220610172924-5.png]]
613 613  
614 -**General Commands**      
615 615  
616 -AT                    : Attention       
664 +(((
665 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
666 +)))
617 617  
618 -AT?                            : Short Help     
619 619  
620 -ATZ                            : MCU Reset    
669 + [[image:image-20220610172924-6.png||height="601" width="860"]]
621 621  
622 -AT+TDC           : Application Data Transmission Interval 
623 623  
624 624  
625 -**Keys, IDs and EUIs management**
626 -
627 -AT+APPEUI              : Application EUI      
628 -
629 -AT+APPKEY              : Application Key     
630 -
631 -AT+APPSKEY            : Application Session Key
632 -
633 -AT+DADDR              : Device Address     
634 -
635 -AT+DEUI                   : Device EUI     
636 -
637 -AT+NWKID               : Network ID (You can enter this command change only after successful network connection) 
638 -
639 -AT+NWKSKEY          : Network Session Key Joining and sending date on LoRa network  
640 -
641 -AT+CFM          : Confirm Mode       
642 -
643 -AT+CFS                     : Confirm Status       
644 -
645 -AT+JOIN          : Join LoRa? Network       
646 -
647 -AT+NJM          : LoRa? Network Join Mode    
648 -
649 -AT+NJS                     : LoRa? Network Join Status    
650 -
651 -AT+RECV                  : Print Last Received Data in Raw Format
652 -
653 -AT+RECVB                : Print Last Received Data in Binary Format      
654 -
655 -AT+SEND                  : Send Text Data      
656 -
657 -AT+SENB                  : Send Hexadecimal Data
658 -
659 -
660 -**LoRa Network Management**
661 -
662 -AT+ADR          : Adaptive Rate
663 -
664 -AT+CLASS                : LoRa Class(Currently only support class A
665 -
666 -AT+DCS           : Duty Cycle Setting 
667 -
668 -AT+DR                      : Data Rate (Can Only be Modified after ADR=0)     
669 -
670 -AT+FCD           : Frame Counter Downlink       
671 -
672 -AT+FCU           : Frame Counter Uplink   
673 -
674 -AT+JN1DL                : Join Accept Delay1
675 -
676 -AT+JN2DL                : Join Accept Delay2
677 -
678 -AT+PNM                   : Public Network Mode   
679 -
680 -AT+RX1DL                : Receive Delay1      
681 -
682 -AT+RX2DL                : Receive Delay2      
683 -
684 -AT+RX2DR               : Rx2 Window Data Rate 
685 -
686 -AT+RX2FQ               : Rx2 Window Frequency
687 -
688 -AT+TXP           : Transmit Power
689 -
690 -
691 -**Information** 
692 -
693 -AT+RSSI           : RSSI of the Last Received Packet   
694 -
695 -AT+SNR           : SNR of the Last Received Packet   
696 -
697 -AT+VER           : Image Version and Frequency Band       
698 -
699 -AT+FDR           : Factory Data Reset
700 -
701 -AT+PORT                  : Application Port    
702 -
703 -AT+CHS           : Get or Set Frequency (Unit: Hz) for Single Channel Mode
704 -
705 - AT+CHE                   : Get or Set eight channels mode, Only for US915, AU915, CN470
706 -
707 -
708 -
709 709  == 3.2  Set Transmit Interval Time ==