... ... @@ -362,6 +362,8 @@
362 362  * If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
363 363  * If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid.
364 364  
365 +
366 +
365 365  === 2.3.3  Interrupt Pin ===
366 366  
367 367  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -525,7 +525,7 @@
525 525  The battery related documents as below:
526 526  
527 527  * (((
528 -[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/le=LSN50-Battery-Dimension.pdf]],
530 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
529 529  )))
530 530  * (((
531 531  [[Lithium-Thionyl Chloride Battery  datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
... ... @@ -538,9 +538,14 @@
538 538  
539 539  
540 540  
543 +== 2.8.2  Battery Note ==
541 541  
542 -=== 2.10. Replace the battery ===
545 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to uplink data, then the battery life may be decreased.
543 543  
547 +
548 +
549 +=== 2.8.3  Replace the battery ===
550 +
544 544  (((
545 545  You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
546 546  )))
... ... @@ -555,88 +555,27 @@
555 555  
556 556  
557 557  
558 -= 3Configure LDDS75 via AT Command or LoRaWAN Downlink =
565 +== 2.8.4  Battery Life Analyze ==
559 559  
560 -(((
561 -(((
562 -Use can configure LDDS75 via AT Command or LoRaWAN Downlink.
563 -)))
564 -)))
567 +Dragino battery powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimate battery life:
565 565  
566 -* (((
567 -(((
568 -AT Command Connection: See [[FAQ>>||anchor="H4.A0FAQ"]].
569 -)))
570 -)))
571 -* (((
572 -(((
573 -LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
574 -)))
575 -)))
569 +[[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
576 576  
577 -(((
578 -(((
579 -
580 -)))
581 581  
582 -(((
583 -There are two kinds of commands to configure LDDS75, they are:
584 -)))
585 -)))
586 586  
587 -* (((
588 -(((
589 -(% style="color:#4f81bd" %)** General Commands**.
590 -)))
591 -)))
573 += 3.  Using the AT Commands =
592 592  
593 593  (((
594 594  (((
595 -These commands are to configure:
596 -)))
597 -)))
598 -
599 -* (((
600 -(((
601 -General system settings like: uplink interval.
602 -)))
603 -)))
604 -* (((
605 -(((
606 -LoRaWAN protocol & radio related command.
607 -)))
608 -)))
609 -
610 -(((
611 -(((
612 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
613 -)))
614 -)))
615 -
616 -(((
617 -(((
618 618  
619 619  )))
620 620  )))
621 621  
622 -* (((
623 -(((
624 -(% style="color:#4f81bd" %)** Commands special design for LDDS75**
625 -)))
626 -)))
627 -
628 -(((
629 -(((
630 -These commands only valid for LDDS75, as below:
631 -)))
632 -)))
633 -
634 -
635 -
636 636  == 3.1  Access AT Commands ==
637 637  
638 -LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below.
583 +LDDS20 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS20 for using AT command, as below.
639 639  
585 +
640 640  [[image:image-20220610172924-4.png||height="483" width="988"]]
641 641  
642 642