Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2025/08/06 17:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -100,6 +100,7 @@ 100 100 * IP66 Waterproof Enclosure 101 101 * 8500mAh Battery for long term use 102 102 103 + 103 103 == 1.3 Suitable Container & Liquid == 104 104 105 105 * Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc. ... ... @@ -109,6 +109,7 @@ 109 109 ** Pure non metal material: <10 mm 110 110 * Pure liquid without irregular deposition. 111 111 113 + 112 112 == 1.4 Mechanical == 113 113 114 114 [[image:image-20220615090910-1.png]] ... ... @@ -141,7 +141,6 @@ 141 141 [[image:image-20220615092044-12.png]] 142 142 143 143 144 - 145 145 (% style="color:blue" %)**Step3: **(%%)Test the installation point. 146 146 147 147 Power on LDDS75, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point. ... ... @@ -170,9 +170,9 @@ 170 170 (% style="color:red" %)Ultrasonic coupling paste (%%) is subjected in most shipping way. So the default package doesn’t include it and user needs to purchase locally. 171 171 172 172 173 - 174 174 (% style="color:blue" %)**Step4: **(%%)Install use Epoxy ab glue. 175 175 176 + 176 176 Prepare Eproxy AB glue. 177 177 178 178 Put Eproxy AB glue in the sensor and press it hard on the container installation point. ... ... @@ -193,35 +193,35 @@ 193 193 194 194 195 195 196 -== 1. 6 Applications ==197 +== 1.5 Applications == 197 197 198 -* Smart liquid control solution. 199 -* Smart liquefied gas solution. 199 +* Horizontal distance measurement 200 +* Liquid level measurement 201 +* Parking management system 202 +* Object proximity and presence detection 203 +* Intelligent trash can management system 204 +* Robot obstacle avoidance 205 +* Automatic control 206 +* Sewer 207 +* Bottom water level monitoring 200 200 201 -== 1. 7Precautions==209 +== 1.6 Pin mapping and power on == 202 202 203 -* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights. 204 -* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container. 205 -* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable. 206 206 207 - == 1.8 Pinmappingand power on==212 +[[image:1654847583902-256.png]] 208 208 209 209 210 -[[image:1655257026882-201.png]] 211 211 216 += 2. Configure LDDS75 to connect to LoRaWAN network = 212 212 213 - 214 -= 2. Configure LDDS20 to connect to LoRaWAN network = 215 - 216 - 217 217 == 2.1 How it works == 218 218 219 219 ((( 220 -The LDDS 20is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LDDS20. If there is coverage of the LoRaWAN network, it will automatically join the network via OTAA and start to send the sensor value.221 +The LDDS75 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LDDS75. If there is coverage of the LoRaWAN network, it will automatically join the network via OTAA and start to send the sensor value 221 221 ))) 222 222 223 223 ((( 224 -In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.A0 UsingtheATCommands"]]to set the keys in the LDDS20.225 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.A0ConfigureLDDS75viaATCommandorLoRaWANDownlink"]]to set the keys in the LDDS75. 225 225 ))) 226 226 227 227 ... ... @@ -233,7 +233,7 @@ 233 233 ))) 234 234 235 235 ((( 236 -[[image:165 5257698953-697.png]]237 +[[image:1654848616367-242.png]] 237 237 ))) 238 238 239 239 ((( ... ... @@ -243,11 +243,11 @@ 243 243 ((( 244 244 245 245 246 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LDDS 20.247 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LDDS75. 247 247 ))) 248 248 249 249 ((( 250 -Each LDDS 20is shipped with a sticker with the default device keys, user can find this sticker in the box. it looks like below.251 +Each LDDS75 is shipped with a sticker with the default device keys, user can find this sticker in the box. it looks like below. 251 251 ))) 252 252 253 253 [[image:image-20220607170145-1.jpeg]] ... ... @@ -277,7 +277,6 @@ 277 277 [[image:image-20220610161353-7.png]] 278 278 279 279 280 - 281 281 You can also choose to create the device manually. 282 282 283 283 [[image:image-20220610161538-8.png]] ... ... @@ -290,17 +290,16 @@ 290 290 291 291 292 292 293 -(% style="color:blue" %)**Step 2**(%%): 20293 +(% style="color:blue" %)**Step 2**(%%): Power on LDDS75 294 294 295 295 296 296 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position). 297 297 298 -[[image:image-2022061 5095102-14.png]]298 +[[image:image-20220610161724-10.png]] 299 299 300 300 301 - 302 302 ((( 303 -(% style="color:blue" %)**Step 3**(%%)**:** 20will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.302 +(% style="color:blue" %)**Step 3**(%%)**:** The LDDS75 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 304 304 ))) 305 305 306 306 [[image:1654849068701-275.png]] ... ... @@ -311,10 +311,12 @@ 311 311 312 312 ((( 313 313 ((( 314 -LDDS20 will uplink payload via LoRaWAN with below payload format: 313 +LDDS75 will uplink payload via LoRaWAN with below payload format: 314 +))) 315 315 316 -Uplink payload includes in total 8 bytes. 317 -Payload for firmware version v1.1.4. . Before v1.1.3, there is only 5 bytes: BAT and Distance(Please check manual v1.2.0 if you have 5 bytes payload). 316 +((( 317 +Uplink payload includes in total 4 bytes. 318 +Payload for firmware version v1.1.4. . Before v1.1.3, there is on two fields: BAT and Distance 318 318 ))) 319 319 ))) 320 320 ... ... @@ -341,7 +341,7 @@ 341 341 === 2.3.1 Battery Info === 342 342 343 343 344 -Check the battery voltage for LDDS 20.345 +Check the battery voltage for LDDS75. 345 345 346 346 Ex1: 0x0B45 = 2885mV 347 347 ... ... @@ -352,19 +352,20 @@ 352 352 === 2.3.2 Distance === 353 353 354 354 ((( 355 -Get the distance. Flat object range 20mm - 2000mm.356 +Get the distance. Flat object range 280mm - 7500mm. 356 356 ))) 357 357 358 358 ((( 359 -For example, if the data you get from the register is __0x060x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0605(H) = 1541(D) = 1541mm.**360 +For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.** 360 360 ))) 361 361 362 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 363 -* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid. 364 364 364 +* If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 365 +* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 366 + 365 365 === 2.3.3 Interrupt Pin === 366 366 367 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3. 2A0SetInterruptMode"]] for the hardware and software set up.369 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. 368 368 369 369 **Example:** 370 370 ... ... @@ -410,41 +410,17 @@ 410 410 The payload decoder function for TTN V3 is here: 411 411 412 412 ((( 413 -LDDS 20TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS20/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]415 +LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 414 414 ))) 415 415 416 416 417 417 418 -== 2.4 DownlinkPayload==420 +== 2.4 Uplink Interval == 419 419 420 - By default,LDDS20prints the downlink payloadtoconsoleport.422 +The LDDS75 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 421 421 422 -[[image:image-20220615100930-15.png]] 423 423 424 424 425 -**Examples:** 426 - 427 - 428 -* (% style="color:blue" %)**Set TDC** 429 - 430 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 431 - 432 -Payload: 01 00 00 1E TDC=30S 433 - 434 -Payload: 01 00 00 3C TDC=60S 435 - 436 - 437 -* (% style="color:blue" %)**Reset** 438 - 439 -If payload = 0x04FF, it will reset the LDDS20 440 - 441 - 442 -* (% style="color:blue" %)**CFM** 443 - 444 -Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 445 - 446 - 447 - 448 448 == 2.5 Show Data in DataCake IoT Server == 449 449 450 450 ((( ... ... @@ -472,7 +472,7 @@ 472 472 473 473 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 474 474 475 -(% style="color:blue" %)**Step 4**(%%)**: Search the LDDS75 and add DevEUI. (% style="color:red" %)(Note: LDDS20 use same payload as LDDS75)(%%)**453 +(% style="color:blue" %)**Step 4**(%%)**: Search the LDDS75 and add DevEUI.** 476 476 477 477 [[image:1654851029373-510.png]] 478 478
- 1655257026882-201.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -492.6 KB - Content
- 1655257698953-697.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -101.7 KB - Content
- image-20220615095102-14.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -179.0 KB - Content
- image-20220615100930-15.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.5 KB - Content