... ... @@ -362,11 +362,11 @@
362 362  === 2.3.2  Distance ===
363 363  
364 364  (((
365 -Get the distance. Flat object range 20mm - 2000mm.
365 +Get the distance. Flat object range 280mm - 7500mm.
366 366  )))
367 367  
368 368  (((
369 -For example, if the data you get from the register is __0x06 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0605(H) = 1541 (D) = 1541 mm.**
369 +For example, if the data you get from the register is 0x0B 0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
370 370  )))
371 371  
372 372  
... ... @@ -373,9 +373,6 @@
373 373  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
374 374  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
375 375  
376 -
377 -
378 -
379 379  === 2.3.3  Interrupt Pin ===
380 380  
381 381  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.