Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2025/08/06 17:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -100,8 +100,6 @@ 100 100 * IP66 Waterproof Enclosure 101 101 * 8500mAh Battery for long term use 102 102 103 - 104 - 105 105 == 1.3 Suitable Container & Liquid == 106 106 107 107 * Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc. ... ... @@ -111,8 +111,6 @@ 111 111 ** Pure non metal material: <10 mm 112 112 * Pure liquid without irregular deposition. 113 113 114 - 115 - 116 116 == 1.4 Mechanical == 117 117 118 118 [[image:image-20220615090910-1.png]] ... ... @@ -202,9 +202,6 @@ 202 202 * Smart liquid control solution. 203 203 * Smart liquefied gas solution. 204 204 205 - 206 - 207 - 208 208 == 1.7 Precautions == 209 209 210 210 * At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights. ... ... @@ -211,9 +211,6 @@ 211 211 * For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container. 212 212 * When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable. 213 213 214 - 215 - 216 - 217 217 == 1.8 Pin mapping and power on == 218 218 219 219 ... ... @@ -227,7 +227,7 @@ 227 227 == 2.1 How it works == 228 228 229 229 ((( 230 -The LDDS20 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LDDS 75. If there is coverage of the LoRaWAN network, it will automatically join the network via OTAA and start to send the sensor value.220 +The LDDS20 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LDDS20. If there is coverage of the LoRaWAN network, it will automatically join the network via OTAA and start to send the sensor value. 231 231 ))) 232 232 233 233 ((( ... ... @@ -321,7 +321,7 @@ 321 321 322 322 ((( 323 323 ((( 324 -LDDS20 will uplink payload via LoRaWAN with below payload format: 314 +LDDS20 will uplink payload via LoRaWAN with below payload format: 325 325 326 326 Uplink payload includes in total 8 bytes. 327 327 Payload for firmware version v1.1.4. . Before v1.1.3, there is only 5 bytes: BAT and Distance(Please check manual v1.2.0 if you have 5 bytes payload). ... ... @@ -351,7 +351,7 @@ 351 351 === 2.3.1 Battery Info === 352 352 353 353 354 -Check the battery voltage for LDDS 75.344 +Check the battery voltage for LDDS20. 355 355 356 356 Ex1: 0x0B45 = 2885mV 357 357 ... ... @@ -362,20 +362,19 @@ 362 362 === 2.3.2 Distance === 363 363 364 364 ((( 365 -Get the distance. Flat object range 2 80mm -7500mm.355 +Get the distance. Flat object range 20mm - 2000mm. 366 366 ))) 367 367 368 368 ((( 369 -For example, if the data you get from the register is 0x0 B0x05, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) =2821 (D) =2821 mm.**359 +For example, if the data you get from the register is __0x06 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0605(H) = 1541 (D) = 1541 mm.** 370 370 ))) 371 371 362 +* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 363 +* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid. 372 372 373 -* If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 374 -* If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 375 - 376 376 === 2.3.3 Interrupt Pin === 377 377 378 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3. 3A0SetInterruptMode"]] for the hardware and software set up.367 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.2A0SetInterruptMode"]] for the hardware and software set up. 379 379 380 380 **Example:** 381 381 ... ... @@ -421,17 +421,41 @@ 421 421 The payload decoder function for TTN V3 is here: 422 422 423 423 ((( 424 -LDDS 75TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]413 +LDDS20 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS20/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 425 425 ))) 426 426 427 427 428 428 429 -== 2.4 UplinkInterval ==418 +== 2.4 Downlink Payload == 430 430 431 - The LDDS75 by defaultuplink the sensor data every20minutes.User can changethis intervalby AT Commandr LoRaWAN DownlinkCommand. See this link: [[Change Uplink Interval>>doc:Main.EndDeviceAT Commandsand DownlinkCommand.WebHome||anchor="H4.1ChangeUplinkInterval"]]420 +By default, LDDS20 prints the downlink payload to console port. 432 432 422 +[[image:image-20220615100930-15.png]] 433 433 434 434 425 +**Examples:** 426 + 427 + 428 +* (% style="color:blue" %)**Set TDC** 429 + 430 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 431 + 432 +Payload: 01 00 00 1E TDC=30S 433 + 434 +Payload: 01 00 00 3C TDC=60S 435 + 436 + 437 +* (% style="color:blue" %)**Reset** 438 + 439 +If payload = 0x04FF, it will reset the LDDS20 440 + 441 + 442 +* (% style="color:blue" %)**CFM** 443 + 444 +Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 445 + 446 + 447 + 435 435 == 2.5 Show Data in DataCake IoT Server == 436 436 437 437 ((( ... ... @@ -459,7 +459,7 @@ 459 459 460 460 (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 461 461 462 -(% style="color:blue" %)**Step 4**(%%)**: Search the LDDS75 and add DevEUI.** 475 +(% style="color:blue" %)**Step 4**(%%)**: Search the LDDS75 and add DevEUI.(% style="color:red" %)(Note: LDDS20 use same payload as LDDS75)(%%)** 463 463 464 464 [[image:1654851029373-510.png]] 465 465
- image-20220615100930-15.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.5 KB - Content