... ... @@ -1,10 +1,11 @@
1 1  (% style="text-align:center" %)
2 -[[image:1655254599445-662.png]]
2 +[[image:1654846127817-788.png]]
3 3  
4 +**Contents:**
4 4  
6 +{{toc/}}
5 5  
6 6  
7 -**Table of Contents:**
8 8  
9 9  
10 10  
... ... @@ -11,11 +11,9 @@
11 11  
12 12  
13 13  
14 -
15 -
16 16  = 1.  Introduction =
17 17  
18 -== 1.1 ​ What is LoRaWAN Ultrasonic liquid leveSensor ==
17 +== 1.1 ​ What is LoRaWAN Distance Detection Sensor ==
19 19  
20 20  (((
21 21  
... ... @@ -22,8 +22,7 @@
22 22  
23 23  (((
24 24  (((
25 -(((
26 -The Dragino LDDS20 is a (% style="color:#4472c4" %)**LoRaWAN Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:#4472c4" %)**none-contact method **(%%)to measure the height of liquid in a container without opening the container, and send the value via LoRaWAN network to IoT Server
24 +The Dragino LDDS75 is a (% style="color:#4472c4" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:#4472c4" %)** ultrasonic sensing** (%%)technology for distance measurement, and (% style="color:#4472c4" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The LDDS75 can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc.
27 27  )))
28 28  
29 29  (((
... ... @@ -31,7 +31,7 @@
31 31  )))
32 32  
33 33  (((
34 -The LDDS20 sensor is installed directly below the container to detect the height of the liquid level. User doesn’t need to open a hole on the container to be tested. The (% style="color:#4472c4" %)**none-contact measurement makes the measurement safety, easier and possible for some strict situation**. 
32 +It detects the distance** (% style="color:#4472c4" %) between the measured object and the sensor(%%)**, and uploads the value via wireless to LoRaWAN IoT Server.
35 35  )))
36 36  
37 37  (((
... ... @@ -39,7 +39,7 @@
39 39  )))
40 40  
41 41  (((
42 -LDDS20 uses ultrasonic sensing technology for distance measurement. LDDS20 is of high accuracy to measure various liquid such as: (% style="color:#4472c4" %)**toxic substances**(%%), (% style="color:#4472c4" %)**strong acids**(%%), (% style="color:#4472c4" %)**strong alkalis**(%%) and (% style="color:#4472c4" %)**various pure liquids**(%%) in high-temperature and high-pressure airtight containers.
40 +The LoRa wireless technology used in LDDS75 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
43 43  )))
44 44  
45 45  (((
... ... @@ -47,7 +47,7 @@
47 47  )))
48 48  
49 49  (((
50 -The LoRa wireless technology used in LDDS20 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
48 +LDDS75 is powered by (% style="color:#4472c4" %)** 4000mA or 8500mAh Li-SOCI2 battery**(%%); It is designed for long term use up to 10 years*.
51 51  )))
52 52  
53 53  (((
... ... @@ -55,7 +55,7 @@
55 55  )))
56 56  
57 57  (((
58 -LDDS20 is powered by (% style="color:#4472c4" %)**8500mA Li-SOCI2 battery**(%%); It is designed for long term use up to 10 years*.
56 +Each LDDS75 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on.
59 59  )))
60 60  
61 61  (((
... ... @@ -63,21 +63,10 @@
63 63  )))
64 64  
65 65  (((
66 -Each LDDS20 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on.
67 -)))
68 -
69 -(((
70 -
71 -)))
72 -)))
73 -
74 -(((
75 -(((
76 76  (% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors.
77 77  )))
78 78  )))
79 79  )))
80 -)))
81 81  
82 82  
83 83  [[image:1654847051249-359.png]]
... ... @@ -106,9 +106,7 @@
106 106  [[image:image-20220610154839-1.png]]
107 107  
108 108  (((
109 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);       **
110 -
111 -**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
96 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing);  b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)**
112 112  )))
113 113  
114 114  
... ... @@ -144,6 +144,7 @@
144 144  * Sewer
145 145  * Bottom water level monitoring
146 146  
132 +
147 147  == 1.6  Pin mapping and power on ==
148 148  
149 149  
... ... @@ -180,8 +180,6 @@
180 180  )))
181 181  
182 182  (((
183 -
184 -
185 185  (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LDDS75.
186 186  )))
187 187  
... ... @@ -201,8 +201,6 @@
201 201  )))
202 202  
203 203  (((
204 -
205 -
206 206  **Add APP EUI in the application**
207 207  )))
208 208  
... ... @@ -302,6 +302,8 @@
302 302  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
303 303  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
304 304  
287 +
288 +
305 305  === 2.3.3  Interrupt Pin ===
306 306  
307 307  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -877,20 +877,16 @@
877 877  * Solid ON for 5 seconds once device successful Join the network.
878 878  * Blink once when device transmit a packet.
879 879  
864 +
865 +
866 +
880 880  == 2.8  ​Firmware Change Log ==
881 881  
882 882  
883 -(((
884 884  **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
885 -)))
886 886  
887 -(((
888 -
889 -)))
890 890  
891 -(((
892 892  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
893 -)))
894 894  
895 895  
896 896  
... ... @@ -1034,9 +1034,7 @@
1034 1034  [[image:image-20220610172924-5.png]]
1035 1035  
1036 1036  
1037 -(((
1038 1038  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below:
1039 -)))
1040 1040  
1041 1041  
1042 1042   [[image:image-20220610172924-6.png||height="601" width="860"]]
... ... @@ -1060,19 +1060,16 @@
1060 1060  (((
1061 1061  Format: Command Code (0x01) followed by 3 bytes time value.
1062 1062  
1063 -(((
1064 1064  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
1065 -)))
1066 1066  
1067 1067  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1068 1068  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1069 1069  )))
1070 -)))
1071 1071  
1072 1072  
1048 +
1049 +)))
1073 1073  
1074 -
1075 -
1076 1076  == 3.3  Set Interrupt Mode ==
1077 1077  
1078 1078  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -1086,9 +1086,7 @@
1086 1086  
1087 1087  Format: Command Code (0x06) followed by 3 bytes.
1088 1088  
1089 -(((
1090 1090  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1091 -)))
1092 1092  
1093 1093  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1094 1094  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1655254599445-662.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -117.0 KB
Content
1655255122126-327.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -101.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0