Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Xiaoling on 2025/04/27 16:45
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LDDS 75- LoRaWANDistanceDetectionSensor User Manual1 +LDDS20 - LoRaWAN Liquid Level Sensor User Manual - Content
-
... ... @@ -1,8 +1,12 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:1654846127817-788.png]] 3 3 4 -**Contents:** 5 5 5 + 6 + 7 + 8 +**Table of Contents:** 9 + 6 6 {{toc/}} 7 7 8 8 ... ... @@ -25,42 +25,22 @@ 25 25 ))) 26 26 27 27 ((( 28 - 29 -))) 30 - 31 -((( 32 32 It detects the distance** (% style="color:#4472c4" %) between the measured object and the sensor(%%)**, and uploads the value via wireless to LoRaWAN IoT Server. 33 33 ))) 34 34 35 35 ((( 36 - 37 -))) 38 - 39 -((( 40 40 The LoRa wireless technology used in LDDS75 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 41 41 ))) 42 42 43 43 ((( 44 - 45 -))) 46 - 47 -((( 48 48 LDDS75 is powered by (% style="color:#4472c4" %)** 4000mA or 8500mAh Li-SOCI2 battery**(%%); It is designed for long term use up to 10 years*. 49 49 ))) 50 50 51 51 ((( 52 - 53 -))) 54 - 55 -((( 56 56 Each LDDS75 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on. 57 57 ))) 58 58 59 59 ((( 60 - 61 -))) 62 - 63 -((( 64 64 (% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors. 65 65 ))) 66 66 ))) ... ... @@ -87,6 +87,7 @@ 87 87 * 4000mAh or 8500mAh Battery for long term use 88 88 89 89 74 + 90 90 == 1.3 Specification == 91 91 92 92 === 1.3.1 Rated environmental conditions === ... ... @@ -94,7 +94,9 @@ 94 94 [[image:image-20220610154839-1.png]] 95 95 96 96 ((( 97 -**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 82 +**Remarks: (1) a. When the ambient temperature is 0-39 ℃, the maximum humidity is 90% (non-condensing); ** 83 + 84 +**~ b. When the ambient temperature is 40-50 ℃, the highest humidity is the highest humidity in the natural world at the current temperature (no condensation)** 98 98 ))) 99 99 100 100 ... ... @@ -168,6 +168,8 @@ 168 168 ))) 169 169 170 170 ((( 158 + 159 + 171 171 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LDDS75. 172 172 ))) 173 173 ... ... @@ -187,6 +187,8 @@ 187 187 ))) 188 188 189 189 ((( 179 + 180 + 190 190 **Add APP EUI in the application** 191 191 ))) 192 192 ... ... @@ -286,6 +286,8 @@ 286 286 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 287 287 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 288 288 280 + 281 + 289 289 === 2.3.3 Interrupt Pin === 290 290 291 291 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H3.3A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -314,9 +314,13 @@ 314 314 315 315 === 2.3.5 Sensor Flag === 316 316 310 +((( 317 317 0x01: Detect Ultrasonic Sensor 312 +))) 318 318 314 +((( 319 319 0x00: No Ultrasonic Sensor 316 +))) 320 320 321 321 322 322 ... ... @@ -329,7 +329,9 @@ 329 329 330 330 The payload decoder function for TTN V3 is here: 331 331 329 +((( 332 332 LDDS75 TTN V3 Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDDS75/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 331 +))) 333 333 334 334 335 335 ... ... @@ -855,13 +855,22 @@ 855 855 * Solid ON for 5 seconds once device successful Join the network. 856 856 * Blink once when device transmit a packet. 857 857 857 + 858 + 858 858 == 2.8 Firmware Change Log == 859 859 860 860 862 +((( 861 861 **Firmware download link: **[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 864 +))) 862 862 866 +((( 867 + 868 +))) 863 863 870 +((( 864 864 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 872 +))) 865 865 866 866 867 867 ... ... @@ -1005,7 +1005,9 @@ 1005 1005 [[image:image-20220610172924-5.png]] 1006 1006 1007 1007 1016 +((( 1008 1008 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below: 1018 +))) 1009 1009 1010 1010 1011 1011 [[image:image-20220610172924-6.png||height="601" width="860"]] ... ... @@ -1029,16 +1029,19 @@ 1029 1029 ((( 1030 1030 Format: Command Code (0x01) followed by 3 bytes time value. 1031 1031 1042 +((( 1032 1032 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 1044 +))) 1033 1033 1034 1034 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1035 1035 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1036 1036 ))) 1049 +))) 1037 1037 1038 1038 1039 - 1040 -))) 1041 1041 1053 + 1054 + 1042 1042 == 3.3 Set Interrupt Mode == 1043 1043 1044 1044 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -1052,11 +1052,15 @@ 1052 1052 1053 1053 Format: Command Code (0x06) followed by 3 bytes. 1054 1054 1068 +((( 1055 1055 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1070 +))) 1056 1056 1057 1057 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1058 1058 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1059 1059 1075 + 1076 + 1060 1060 = 4. FAQ = 1061 1061 1062 1062 == 4.1 What is the frequency plan for LDDS75? == ... ... @@ -1116,6 +1116,8 @@ 1116 1116 * (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1117 1117 * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1118 1118 1136 + 1137 + 1119 1119 = 7. Packing Info = 1120 1120 1121 1121 ... ... @@ -1130,6 +1130,8 @@ 1130 1130 * Package Size / pcs : cm 1131 1131 * Weight / pcs : g 1132 1132 1152 + 1153 + 1133 1133 = 8. Support = 1134 1134 1135 1135 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- 1655254599445-662.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +117.0 KB - Content