Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Xiaoling on 2025/04/27 16:45
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,7 +3,6 @@ 3 3 4 4 **Contents:** 5 5 6 -{{toc/}} 7 7 8 8 9 9 ... ... @@ -11,7 +11,6 @@ 11 11 12 12 13 13 14 - 15 15 = 1. Introduction = 16 16 17 17 == 1.1 What is LoRaWAN Distance Detection Sensor == ... ... @@ -20,51 +20,24 @@ 20 20 21 21 22 22 ((( 23 -((( 24 24 The Dragino LDDS75 is a (% style="color:#4472c4" %)** LoRaWAN Distance Detection Sensor**(%%) for Internet of Things solution. It is used to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses (% style="color:#4472c4" %)** ultrasonic sensing** (%%)technology for distance measurement, and (% style="color:#4472c4" %)** temperature compensation**(%%) is performed internally to improve the reliability of data. The LDDS75 can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. 25 -))) 26 26 27 -((( 28 - 29 -))) 30 30 31 -((( 32 32 It detects the distance** (% style="color:#4472c4" %) between the measured object and the sensor(%%)**, and uploads the value via wireless to LoRaWAN IoT Server. 33 -))) 34 34 35 -((( 36 - 37 -))) 38 38 39 -((( 40 40 The LoRa wireless technology used in LDDS75 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 41 -))) 42 42 43 -((( 44 - 45 -))) 46 46 47 -((( 48 48 LDDS75 is powered by (% style="color:#4472c4" %)** 4000mA or 8500mAh Li-SOCI2 battery**(%%); It is designed for long term use up to 10 years*. 49 -))) 50 50 51 -((( 52 - 53 -))) 54 54 55 -((( 56 56 Each LDDS75 pre-loads with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect if there is network coverage, after power on. 57 -))) 58 58 59 -((( 60 - 61 -))) 62 62 63 -((( 64 -(% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors. 36 +(% style="color:#4472c4" %) * (%%)Actually lifetime depends on network coverage and uplink interval and other factors 65 65 ))) 66 66 ))) 67 -))) 68 68 69 69 70 70 [[image:1654847051249-359.png]] ... ... @@ -107,7 +107,6 @@ 107 107 [[image:1654852253176-749.png]] 108 108 109 109 110 - 111 111 **(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.** 112 112 113 113 ... ... @@ -235,12 +235,12 @@ 235 235 **Size (bytes)** 236 236 )))|=(% style="width: 62.5px;" %)**2**|=**2**|=1|=2|=**1** 237 237 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 238 -[[Distance>>||anchor="H2.3. 2A0Distance"]]208 +[[Distance>>||anchor="H2.3.3A0Distance"]] 239 239 240 240 (unit: mm) 241 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3. 3A0InterruptPin"]]|(((242 -[[Temperature (Optional )>>||anchor="H2.3. 4A0DS18B20Temperaturesensor"]]243 -)))|[[Sensor Flag>> ||anchor="H2.3.5A0SensorFlag"]]211 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.4A0Distancesignalstrength"]]|((( 212 +[[Temperature (Optional )>>||anchor="H2.3.5A0InterruptPin"]] 213 +)))|[[Sensor Flag>>path:#Sensor_Flag]] 244 244 245 245 [[image:1654850511545-399.png]] 246 246 ... ... @@ -267,10 +267,9 @@ 267 267 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 268 268 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 269 269 270 - 271 271 === 2.3.3 Interrupt Pin === 272 272 273 -This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H 3.3A0SetInterruptMode"]] for the hardware and software set up.242 +This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up. 274 274 275 275 **Example:** 276 276 ... ... @@ -301,9 +301,9 @@ 301 301 0x00: No Ultrasonic Sensor 302 302 303 303 273 +=== 274 +(% style="color:inherit; font-family:inherit" %)2.3.6 Decode payload in The Things Network(%%) === 304 304 305 -=== 2.3.6 Decode payload in The Things Network === 306 - 307 307 While using TTN network, you can add the payload format to decode the payload. 308 308 309 309 ... ... @@ -837,7 +837,6 @@ 837 837 * Solid ON for 5 seconds once device successful Join the network. 838 838 * Blink once when device transmit a packet. 839 839 840 - 841 841 == 2.8 Firmware Change Log == 842 842 843 843 ... ... @@ -853,11 +853,9 @@ 853 853 854 854 [[image:image-20220610172003-1.png]] 855 855 856 - 857 857 [[image:image-20220610172003-2.png]] 858 858 859 859 860 - 861 861 == 2.10 Battery Analysis == 862 862 863 863 === 2.10.1 Battery Type === ... ... @@ -868,7 +868,7 @@ 868 868 The battery related documents as below: 869 869 870 870 * ((( 871 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 837 +[[ Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 872 872 ))) 873 873 * ((( 874 874 [[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], ... ... @@ -884,7 +884,7 @@ 884 884 === 2.10.2 Replace the battery === 885 885 886 886 ((( 887 -You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won 't be voltage drop between battery and main board.853 +You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 888 888 ))) 889 889 890 890 ((( ... ... @@ -892,12 +892,12 @@ 892 892 ))) 893 893 894 894 ((( 895 -The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can 't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)861 +The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can’t find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 896 896 ))) 897 897 898 898 899 899 900 -= 3. Configure LD DS75via AT Command or LoRaWAN Downlink =866 += 3. Configure LLDS12 via AT Command or LoRaWAN Downlink = 901 901 902 902 ((( 903 903 ((( ... ... @@ -907,7 +907,7 @@ 907 907 908 908 * ((( 909 909 ((( 910 -AT Command Connection: See [[FAQ>>||anchor="H 4.A0FAQ"]].876 +AT Command Connection: See [[FAQ>>||anchor="H7.A0FAQ"]]. 911 911 ))) 912 912 ))) 913 913 * ((( ... ... @@ -1028,7 +1028,7 @@ 1028 1028 1029 1029 (% style="color:#037691" %)**Downlink Command: AT+INTMOD** 1030 1030 1031 -[[image:image-202206101 74917-9.png]]997 +[[image:image-20220610105907-1.png]] 1032 1032 1033 1033 1034 1034 (% style="color:#037691" %)**Downlink Command: 0x06** ... ... @@ -1042,67 +1042,106 @@ 1042 1042 1043 1043 1044 1044 1045 -= 4. FAQ = 1046 1046 1047 -= =4.1What isthefrequencyplanfor LDDS75?==1012 += 6. Use AT Command = 1048 1048 1049 - LDDS75usethe same frequency as other Dragino products. User cansee the detail from thislink:[[Introduction>>doc:Main.EndDevice Frequency Band.WebHome||anchor="H1.Introduction"]]1014 +== 6.1 Access AT Commands == 1050 1050 1016 +LLDS12 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12 for using AT command, as below. 1051 1051 1018 +[[image:1654593668970-604.png]] 1052 1052 1053 - == 4.2 How to change the LoRa Frequency Bands/Region==1020 +**Connection:** 1054 1054 1055 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1056 -When downloading the images, choose the required image file for download. 1022 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 1057 1057 1024 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 1058 1058 1026 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 1059 1059 1060 -== 4.3 Can I use LDDS75 in condensation environment? == 1061 1061 1062 -LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0. 1029 +((( 1030 +((( 1031 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12. 1032 +))) 1063 1063 1034 +((( 1035 +LLDS12 will output system info once power on as below: 1036 +))) 1037 +))) 1064 1064 1065 1065 1066 - =5.Trouble Shooting=1040 + [[image:1654593712276-618.png]] 1067 1067 1068 - ==5.1WhyIcan’tjoinTTN V3inUS915 /AU915 bands? ==1042 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]]. 1069 1069 1070 -It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1071 1071 1045 += 4. FAQ = 1072 1072 1073 -== 5.2ATCommandinputdoesn'twork==1047 +== 4.1 How to change the LoRa Frequency Bands/Region == 1074 1074 1049 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1050 +When downloading the images, choose the required image file for download. 1051 + 1052 + 1053 += 5. Trouble Shooting = 1054 + 1055 +== 5.1 AT Commands input doesn’t work == 1056 + 1057 + 1058 +((( 1075 1075 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1060 +))) 1076 1076 1062 + 1063 +== 5.2 Significant error between the output distant value of LiDAR and actual distance == 1064 + 1065 + 1077 1077 ((( 1067 +(% style="color:blue" %)**Cause ①**(%%)**:**Due to the physical principles of The LiDAR probe, the above phenomenon is likely to occur if the detection object is the material with high reflectivity (such as mirror, smooth floor tile, etc.) or transparent substance (such as glass and water, etc.) 1068 +))) 1069 + 1070 +((( 1071 +Troubleshooting: Please avoid use of this product under such circumstance in practice. 1072 +))) 1073 + 1074 +((( 1078 1078 1079 1079 ))) 1080 1080 1078 +((( 1079 +(% style="color:blue" %)**Cause ②**(%%)**: **The IR-pass filters are blocked. 1080 +))) 1081 1081 1082 +((( 1083 +Troubleshooting: please use dry dust-free cloth to gently remove the foreign matter. 1084 +))) 1085 + 1086 + 1087 + 1082 1082 = 6. Order Info = 1083 1083 1084 1084 1085 -Part Number **:**(% style="color:blue" %)**LDDS75-XX-YY**1091 +Part Number: (% style="color:blue" %)**LDDS75-XX-YY** 1086 1086 1087 1087 1088 -(% style="color:blue" %)**XX**(%%) **:**The default frequency band1094 +(% style="color:blue" %)**XX**(%%): The default frequency band 1089 1089 1090 -* (% style="color:red" %)**AS923 **:**LoRaWAN AS923 band1091 -* (% style="color:red" %)**AU915 **:**LoRaWAN AU915 band1092 -* (% style="color:red" %)**EU433 **:**LoRaWAN EU433 band1093 -* (% style="color:red" %)**EU868 **:**LoRaWAN EU868 band1094 -* (% style="color:red" %)**KR920 **:**LoRaWAN KR920 band1095 -* (% style="color:red" %)**US915 **:**LoRaWAN US915 band1096 -* (% style="color:red" %)**IN865 **:**LoRaWAN IN865 band1097 -* (% style="color:red" %)**CN470 **:**LoRaWAN CN470 band1096 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1097 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1098 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1099 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1100 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1101 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1102 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1103 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1098 1098 1099 1099 (% style="color:blue" %)**YY**(%%): Battery Option 1100 1100 1101 -* (% style="color:red" %)**4 **:**4000mAh battery1102 -* (% style="color:red" %)**8 **:**8500mAh battery1107 +* (% style="color:red" %)**4**(%%): 4000mAh battery 1108 +* (% style="color:red" %)**8**(%%): 8500mAh battery 1103 1103 1104 1104 1105 - 1106 1106 = 7. Packing Info = 1107 1107 1108 1108 ... ... @@ -1118,7 +1118,6 @@ 1118 1118 * Weight / pcs : g 1119 1119 1120 1120 1121 - 1122 1122 = 8. Support = 1123 1123 1124 1124 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220610174917-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.3 KB - Content