From version < 138.3 >
edited by Xiaoling
on 2022/06/10 17:04
To version < 138.9 >
edited by Xiaoling
on 2022/06/10 17:09
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,8 +58,6 @@
58 58  * 4000mAh or 8500mAh Battery for long term use
59 59  
60 60  
61 -
62 -
63 63  == 1.3  Specification ==
64 64  
65 65  === 1.3.1  Rated environmental conditions ===
... ... @@ -74,16 +74,20 @@
74 74  
75 75  === 1.3.2  Effective measurement range Reference beam pattern ===
76 76  
77 -**(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**[[image:image-20220610155021-2.png||height="440" width="1189"]]
75 +**(1) The tested object is a white cylindrical tube made of PVC, with a height of 100cm and a diameter of 7.5cm.**
78 78  
79 79  
78 +[[image:image-20220610155021-2.png||height="377" width="1021"]]
80 80  
81 -**(2)** The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.[[image:image-20220610155021-3.png||height="437" width="1192"]]
82 82  
83 -(% style="display:none" %) (%%)
84 84  
82 +**(2)** **The object to be tested is a "corrugated cardboard box" perpendicular to the central axis of 0 °, and the length * width is 60cm * 50cm.**
85 85  
86 86  
85 +(% style="display:none" %) [[image:image-20220610155021-3.png||height="374" width="1020"]]** **
86 +
87 +
88 +
87 87  == 1.5 ​ Applications ==
88 88  
89 89  * Horizontal distance measurement
... ... @@ -97,8 +97,6 @@
97 97  * Bottom water level monitoring
98 98  
99 99  
100 -
101 -
102 102  == 1.6  Pin mapping and power on ==
103 103  
104 104  
... ... @@ -119,6 +119,7 @@
119 119  )))
120 120  
121 121  
122 +
122 122  == 2.2  ​Quick guide to connect to LoRaWAN server (OTAA) ==
123 123  
124 124  (((
... ... @@ -239,6 +239,7 @@
239 239  * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid.
240 240  
241 241  
243 +
242 242  === 2.3.3  Interrupt Pin ===
243 243  
244 244  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -250,6 +250,7 @@
250 250  0x01: Interrupt Uplink Packet.
251 251  
252 252  
255 +
253 253  === 2.3.4  DS18B20 Temperature sensor ===
254 254  
255 255  This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0