Changes for page LMDS200 -- LoRaWAN Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/03/07 08:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,6 +57,8 @@ 57 57 * IP66 Waterproof Enclosure 58 58 * 4000mAh or 8500mAh Battery for long term use 59 59 60 + 61 + 60 60 == 1.3 Specification == 61 61 62 62 === 1.3.1 Rated environmental conditions === ... ... @@ -80,6 +80,7 @@ 80 80 (% style="display:none" %) (%%) 81 81 82 82 85 + 83 83 == 1.5 Applications == 84 84 85 85 * Horizontal distance measurement ... ... @@ -92,6 +92,8 @@ 92 92 * Sewer 93 93 * Bottom water level monitoring 94 94 98 + 99 + 95 95 == 1.6 Pin mapping and power on == 96 96 97 97 ... ... @@ -98,6 +98,7 @@ 98 98 [[image:1654847583902-256.png]] 99 99 100 100 106 + 101 101 = 2. Configure LDDS75 to connect to LoRaWAN network = 102 102 103 103 == 2.1 How it works == ... ... @@ -111,6 +111,7 @@ 111 111 ))) 112 112 113 113 120 + 114 114 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 115 115 116 116 ((( ... ... @@ -230,8 +230,6 @@ 230 230 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 231 231 * If the sensor value lower than 0x0118 (280mm), the sensor value will be invalid. Since v1.1.4, all value lower than 280mm will be set to 0x0014(20mm) which means the value is invalid. 232 232 233 - 234 - 235 235 === 2.3.3 Interrupt Pin === 236 236 237 237 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.2A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -329,6 +329,7 @@ 329 329 ))) 330 330 331 331 337 + 332 332 === 2.6.1 EU863-870 (EU868) === 333 333 334 334 ((( ... ... @@ -529,24 +529,51 @@ 529 529 === 2.6.4 AU915-928(AU915) === 530 530 531 531 ((( 532 -Frequency band as per definition in LoRaWAN 1.0.3 Regional document. 533 -))) 538 +Default use CHE=2 534 534 535 -((( 536 -To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. 537 -))) 540 +(% style="color:blue" %)**Uplink:** 538 538 539 -((( 540 - 541 -))) 542 +916.8 - SF7BW125 to SF12BW125 542 542 543 -((( 544 -After Join success, the end node will switch to the correct sub band by: 545 -))) 544 +917.0 - SF7BW125 to SF12BW125 546 546 547 -* Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 548 -* Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 546 +917.2 - SF7BW125 to SF12BW125 549 549 548 +917.4 - SF7BW125 to SF12BW125 549 + 550 +917.6 - SF7BW125 to SF12BW125 551 + 552 +917.8 - SF7BW125 to SF12BW125 553 + 554 +918.0 - SF7BW125 to SF12BW125 555 + 556 +918.2 - SF7BW125 to SF12BW125 557 + 558 + 559 +(% style="color:blue" %)**Downlink:** 560 + 561 +923.3 - SF7BW500 to SF12BW500 562 + 563 +923.9 - SF7BW500 to SF12BW500 564 + 565 +924.5 - SF7BW500 to SF12BW500 566 + 567 +925.1 - SF7BW500 to SF12BW500 568 + 569 +925.7 - SF7BW500 to SF12BW500 570 + 571 +926.3 - SF7BW500 to SF12BW500 572 + 573 +926.9 - SF7BW500 to SF12BW500 574 + 575 +927.5 - SF7BW500 to SF12BW500 576 + 577 +923.3 - SF12BW500(RX2 downlink only) 578 + 579 + 580 + 581 +))) 582 + 550 550 === 2.6.5 AS920-923 & AS923-925 (AS923) === 551 551 552 552 (((