<
From version < 111.22 >
edited by Xiaoling
on 2022/06/10 14:31
To version < 111.30 >
edited by Xiaoling
on 2022/06/10 14:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -300,7 +300,6 @@
300 300  |(% style="width:160px" %)0x01|(% style="width:163px" %)Normal Uplink|(% style="width:173px" %)[[Normal Uplink Payload>>||anchor="H2.3A0200BUplinkPayload"]]
301 301  |(% style="width:160px" %)0x02|(% style="width:163px" %)Reply configures info|(% style="width:173px" %)[[Configure Info Payload>>||anchor="H4.3A0GetFirmwareVersionInfo"]]
302 302  
303 -
304 304  === 2.3.8  Decode payload in The Things Network ===
305 305  
306 306  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -469,8 +469,6 @@
469 469  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
470 470  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
471 471  
472 -
473 -
474 474  === 2.6.3  CN470-510 (CN470) ===
475 475  
476 476  (((
... ... @@ -581,8 +581,6 @@
581 581  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
582 582  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
583 583  
584 -
585 -
586 586  === 2.6.5  AS920-923 & AS923-925 (AS923) ===
587 587  
588 588  (((
... ... @@ -809,7 +809,6 @@
809 809  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
810 810  * Blink once when device transmit a packet.
811 811  
812 -
813 813  == 2.8  ​Firmware Change Log ==
814 814  
815 815  
... ... @@ -837,11 +837,11 @@
837 837  [[image:1654831774373-275.png]]
838 838  
839 839  
840 -①Represents the detection blind zone of The LiDAR probe, 0-10cm, within which the output data is unreliable.
834 +(% style="color:blue" %)** **(%%)Represents the detection blind zone of The LiDAR probe, 0-10cm, within which the output data is unreliable.
841 841  
842 -②Represents the operating range of The LiDAR probe detecting black target with 10% reflectivity, 0.1-5m.
836 +(% style="color:blue" %)** **(%%)Represents the operating range of The LiDAR probe detecting black target with 10% reflectivity, 0.1-5m.
843 843  
844 -③Represents the operating range of The LiDAR probe detecting white target with 90% reflectivity, 0.1-12m.
838 +(% style="color:blue" %)** **(%%)Represents the operating range of The LiDAR probe detecting white target with 90% reflectivity, 0.1-12m.
845 845  
846 846  
847 847  Vertical Coordinates: Represents the radius of light spot for The LiDAR probe at the different distances. The diameter of light spot depends on the FOV of The LiDAR probe (the term of FOV generally refers to the smaller value between the receiving angle and the transmitting angle), which is calculated as follows:
... ... @@ -982,9 +982,6 @@
982 982  Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
983 983  )))
984 984  
985 -
986 -
987 -
988 988  == 4.3  Get Firmware Version Info ==
989 989  
990 990  Feature: use downlink to get firmware version.
... ... @@ -1181,13 +1181,15 @@
1181 1181  
1182 1182  
1183 1183  (((
1184 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
1175 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LLDS12.
1176 +
1177 +LLDS12 will output system info once power on as below:
1185 1185  )))
1186 1186  
1187 1187  
1188 1188   [[image:1654593712276-618.png]]
1189 1189  
1190 -Valid AT Command please check [[Configure Device>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]].
1183 +Valid AT Command please check [[Configure Device>>||anchor="H4.A0ConfigureLLDS12viaATCommandorLoRaWANDownlink"]].
1191 1191  
1192 1192  
1193 1193  = 7.  FAQ =
... ... @@ -1194,7 +1194,7 @@
1194 1194  
1195 1195  == 7.1  How to change the LoRa Frequency Bands/Region ==
1196 1196  
1197 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
1190 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]].
1198 1198  When downloading the images, choose the required image file for download. ​
1199 1199  
1200 1200  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0