From version < 34.2 >
edited by Xiaoling
on 2022/06/07 16:05
To version < 29.2 >
edited by Xiaoling
on 2022/06/07 15:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -434,8 +434,6 @@
434 434  * Reply to the confirmation package: 14 01
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 -
438 -
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -671,7 +671,6 @@
671 671  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
672 672  * Blink once when device transmit a packet.
673 673  
674 -
675 675  == 2.10 ​Firmware Change Log ==
676 676  
677 677  
... ... @@ -740,6 +740,8 @@
740 740  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
741 741  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
742 742  
740 +
741 +
743 743  == 3.2 Set Interrupt Mode ==
744 744  
745 745  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -758,6 +758,8 @@
758 758  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
759 759  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
760 760  
760 +
761 +
761 761  == 3.3 Calibrate Sensor ==
762 762  
763 763  Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -779,10 +779,11 @@
779 779  
780 780  Configures info payload:
781 781  
782 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
783 -|=(((
784 -**Size(bytes)**
785 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
783 +|(((
784 +**Size**
785 +
786 +**(bytes)**
787 +)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
786 786  |**Value**|Software Type|(((
787 787  Frequency
788 788  
... ... @@ -792,7 +792,10 @@
792 792  
793 793  Version
794 794  )))|Sensor Type|Reserve|(((
795 -[[Message Type>>||anchor="H2.3.6MessageType"]]
797 +[[Message>>path:#Message_Type]]
798 +
799 +[[Type>>path:#Message_Type]]
800 +
796 796  Always 0x02
797 797  )))
798 798  
... ... @@ -846,19 +846,18 @@
846 846  
847 847  
848 848  
849 -= 4. Battery & How to replace =
850 850  
851 -== 4.1 Battery Type ==
852 852  
853 -(((
856 +
857 +1. Battery & How to replace
858 +11. Battery Type
859 +
854 854  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
855 -)))
856 856  
857 -(((
862 +
858 858  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
859 -)))
860 860  
861 -[[image:1654588469844-778.png]]
865 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
862 862  
863 863  
864 864  Minimum Working Voltage for the LSPH01:
... ... @@ -866,36 +866,30 @@
866 866  LSPH01:  2.45v ~~ 3.6v
867 867  
868 868  
873 +1.
874 +11. Replace Battery
869 869  
870 -== 4.2 Replace Battery ==
871 -
872 -(((
873 873  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
874 -)))
875 875  
876 -(((
877 877  And make sure the positive and negative pins match.
878 -)))
879 879  
880 880  
881 881  
882 -== 4.3 Power Consumption Analyze ==
882 +1.
883 +11. Power Consumption Analyze
883 883  
884 -(((
885 885  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
886 -)))
887 887  
888 -(((
887 +
889 889  Instruction to use as below:
890 -)))
891 891  
892 892  
893 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
891 +Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
894 894  
895 895  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
896 896  
897 897  
898 -**Step 2**: Open it and choose
896 +Step 2: Open it and choose
899 899  
900 900  * Product Model
901 901  * Uplink Interval
... ... @@ -903,62 +903,64 @@
903 903  
904 904  And the Life expectation in difference case will be shown on the right.
905 905  
906 -[[image:1654588577573-122.png]]
904 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
907 907  
908 908  
909 909  The battery related documents as below:
910 910  
911 -* (((
912 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
909 +* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
910 +* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet
911 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
912 +
913 +|(((
914 +JST-XH-2P connector
913 913  )))
914 -* (((
915 -[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
916 -)))
917 -* (((
918 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
919 -)))
920 920  
921 -[[image:image-20220607155856-8.png]]
917 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
922 922  
923 923  
924 924  
925 -=== 4.3.1 ​Battery Note ===
921 +1.
922 +11.
923 +111. ​Battery Note
926 926  
927 -(((
928 928  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
929 -)))
930 930  
931 931  
928 +1.
929 +11.
930 +111. ​Replace the battery
932 932  
933 -=== ​4.3.2 Replace the battery ===
934 -
935 935  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
936 936  
934 +
937 937  The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
938 938  
939 939  
940 940  
941 -= 5. Use AT Command =
942 942  
943 -== 5.1 Access AT Commands ==
944 944  
941 +
942 +1. Use AT Command
943 +11. Access AT Commands
944 +
945 945  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
946 946  
947 -[[image:1654589001411-343.png]]
947 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
948 948  
949 949  Connection:
950 950  
951 -(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
951 +USB TTL GND <~-~-~-~-> GND
952 952  
953 -(% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
953 +USB TTL TXD <~-~-~-~-> UART_RXD
954 954  
955 -(% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
955 +USB TTL RXD <~-~-~-~-> UART_TXD
956 956  
957 957  
958 958  In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
959 959  
960 960  
961 - [[image:1654589062541-567.png]]
961 + [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
962 962  
963 963  Valid AT Command please check [[Configure Device>>path:#Configure_Device]].
964 964  
1654588469844-778.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -75.8 KB
Content
1654588577573-122.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -138.2 KB
Content
1654589001411-343.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -546.2 KB
Content
1654589062541-567.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -144.0 KB
Content
image-20220607155856-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -83.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0