From version < 30.5 >
edited by Xiaoling
on 2022/06/07 15:55
To version < 34.11 >
edited by Xiaoling
on 2022/06/07 16:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -434,8 +434,6 @@
434 434  * Reply to the confirmation package: 14 01
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 -
438 -
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -492,7 +492,6 @@
492 492  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
493 493  
494 494  
495 -
496 496  === 2.8.3 CN470-510 (CN470) ===
497 497  
498 498  Used in China, Default use CHE=1
... ... @@ -559,9 +559,6 @@
559 559  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
560 560  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
561 561  
562 -
563 -
564 -
565 565  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
566 566  
567 567  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -900,12 +900,12 @@
900 900  )))
901 901  
902 902  
903 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
897 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
904 904  
905 905  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
906 906  
907 907  
908 -Step 2: Open it and choose
902 +**Step 2**: Open it and choose
909 909  
910 910  * Product Model
911 911  * Uplink Interval
... ... @@ -913,64 +913,62 @@
913 913  
914 914  And the Life expectation in difference case will be shown on the right.
915 915  
916 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
910 +[[image:1654588577573-122.png]]
917 917  
918 918  
919 919  The battery related documents as below:
920 920  
921 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
922 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet
923 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
924 -
925 -|(((
926 -JST-XH-2P connector
915 +* (((
916 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
927 927  )))
918 +* (((
919 +[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
920 +)))
921 +* (((
922 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
923 +)))
928 928  
929 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
925 +[[image:image-20220607155856-8.png]]
930 930  
931 931  
932 932  
933 -1.
934 -11.
935 -111. ​Battery Note
929 +=== 4.3.1 ​Battery Note ===
936 936  
931 +(((
937 937  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
933 +)))
938 938  
939 939  
940 -1.
941 -11.
942 -111. ​Replace the battery
943 943  
937 +=== ​4.3.2 Replace the battery ===
938 +
944 944  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
945 945  
946 -
947 947  The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
948 948  
949 949  
950 950  
945 += 5. Use AT Command =
951 951  
947 +== 5.1 Access AT Commands ==
952 952  
953 -
954 -1. Use AT Command
955 -11. Access AT Commands
956 -
957 957  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
958 958  
959 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
951 +[[image:1654589001411-343.png]]
960 960  
961 -Connection:
953 +**Connection:**
962 962  
963 -USB TTL GND <~-~-~-~-> GND
955 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
964 964  
965 -USB TTL TXD <~-~-~-~-> UART_RXD
957 +(% style="background-color:yellow" %)** USB TTL TXD  <~-~-~-~-> UART_RXD**
966 966  
967 -USB TTL RXD <~-~-~-~-> UART_TXD
959 +(% style="background-color:yellow" %)** USB TTL RXD  <~-~-~-~-> UART_TXD**
968 968  
969 969  
970 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
962 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below:
971 971  
972 972  
973 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
965 + [[image:1654589062541-567.png]]
974 974  
975 975  Valid AT Command please check [[Configure Device>>path:#Configure_Device]].
976 976  
... ... @@ -977,38 +977,43 @@
977 977  
978 978  
979 979  
980 -1. FAQ
981 -11. How to change the LoRa Frequency Bands/Region
972 += 6. FAQ =
982 982  
983 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]].
974 +== 6.1 How to change the LoRa Frequency Bands/Region ==
975 +
976 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
984 984  When downloading the images, choose the required image file for download. ​
985 985  
986 986  
987 987  
988 -1. Trouble Shooting
989 -11. AT Commands input doesn’t work
981 += 7. Trouble Shooting =
990 990  
991 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string.
983 +== 7.1 AT Commands input doesn’t work ==
992 992  
985 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
993 993  
994 -1. Order Info
995 995  
996 -Part Number: **LSPH01-XX**
997 997  
989 += 8. Order Info =
998 998  
999 -**XX**: The default frequency band
991 +Part Number: (% style="color:blue" %)**LSPH01-XX**
1000 1000  
1001 -* **AS923**: LoRaWAN AS923 band
1002 -* **AU915**: LoRaWAN AU915 band
1003 -* **EU433**: LoRaWAN EU433 band
1004 -* **EU868**: LoRaWAN EU868 band
1005 -* **KR920**: LoRaWAN KR920 band
1006 -* **US915**: LoRaWAN US915 band
1007 -* **IN865**: LoRaWAN IN865 band
1008 -* **CN470**: LoRaWAN CN470 band
1009 1009  
1010 -1. ​Packing Info
994 +(% style="color:blue" %)**XX**(%%): The default frequency band
1011 1011  
996 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
997 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
998 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
999 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
1000 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
1001 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
1002 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1003 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1004 +
1005 +
1006 += 9. ​Packing Info =
1007 +
1008 +
1012 1012  **Package Includes**:
1013 1013  
1014 1014  * LSPH01 LoRaWAN Soil Ph Sensor x 1
... ... @@ -1020,6 +1020,8 @@
1020 1020  * Package Size / pcs : cm
1021 1021  * Weight / pcs : g
1022 1022  
1020 +
1021 +
1023 1023  = 10. ​Support =
1024 1024  
1025 1025  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1654588577573-122.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +138.2 KB
Content
1654589001411-343.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +546.2 KB
Content
1654589062541-567.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +144.0 KB
Content
image-20220607155856-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +83.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0