<
From version < 30.4 >
edited by Xiaoling
on 2022/06/07 15:55
To version < 33.2 >
edited by Xiaoling
on 2022/06/07 16:03
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -435,7 +435,6 @@
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 437  
438 -
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -492,7 +492,6 @@
492 492  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
493 493  
494 494  
495 -
496 496  === 2.8.3 CN470-510 (CN470) ===
497 497  
498 498  Used in China, Default use CHE=1
... ... @@ -561,7 +561,6 @@
561 561  
562 562  
563 563  
564 -
565 565  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
566 566  
567 567  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -677,7 +677,6 @@
677 677  
678 678  
679 679  
680 -
681 681  == 2.10 ​Firmware Change Log ==
682 682  
683 683  
... ... @@ -746,7 +746,6 @@
746 746  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
747 747  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
748 748  
749 -
750 750  == 3.2 Set Interrupt Mode ==
751 751  
752 752  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -765,7 +765,6 @@
765 765  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
766 766  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
767 767  
768 -
769 769  == 3.3 Calibrate Sensor ==
770 770  
771 771  Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -784,7 +784,6 @@
784 784  * Reply to non-confirmed packet: 26 00
785 785  
786 786  
787 -
788 788  Device will send an uplink after got this downlink command. With below payload:
789 789  
790 790  Configures info payload:
... ... @@ -879,26 +879,33 @@
879 879  
880 880  == 4.2 Replace Battery ==
881 881  
875 +(((
882 882  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
877 +)))
883 883  
879 +(((
884 884  And make sure the positive and negative pins match.
881 +)))
885 885  
886 886  
887 887  
888 888  == 4.3 Power Consumption Analyze ==
889 889  
887 +(((
890 890  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
889 +)))
891 891  
892 -
891 +(((
893 893  Instruction to use as below:
893 +)))
894 894  
895 895  
896 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
896 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
897 897  
898 898  [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
899 899  
900 900  
901 -Step 2: Open it and choose
901 +**Step 2**: Open it and choose
902 902  
903 903  * Product Model
904 904  * Uplink Interval
... ... @@ -906,50 +906,48 @@
906 906  
907 907  And the Life expectation in difference case will be shown on the right.
908 908  
909 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
909 +[[image:1654588577573-122.png]]
910 910  
911 911  
912 912  The battery related documents as below:
913 913  
914 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
915 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet
916 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
917 -
918 -|(((
919 -JST-XH-2P connector
914 +* (((
915 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
920 920  )))
917 +* (((
918 +[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
919 +)))
920 +* (((
921 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
922 +)))
921 921  
922 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
924 +[[image:image-20220607155856-8.png]]
923 923  
924 924  
925 925  
926 -1.
927 -11.
928 -111. ​Battery Note
928 +=== 4.3.1 ​Battery Note ===
929 929  
930 +(((
930 930  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
932 +)))
931 931  
932 932  
933 -1.
934 -11.
935 -111. ​Replace the battery
936 936  
936 +=== ​4.3.2 Replace the battery ===
937 +
937 937  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
938 938  
939 -
940 940  The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
941 941  
942 942  
943 943  
944 += 5. Use AT Command =
944 944  
946 +== 5.1 Access AT Commands ==
945 945  
946 -
947 -1. Use AT Command
948 -11. Access AT Commands
949 -
950 950  LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below.
951 951  
952 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
950 +[[image:1654589001411-343.png]]
953 953  
954 954  Connection:
955 955  
1654588577573-122.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +138.2 KB
Content
1654589001411-343.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +546.2 KB
Content
image-20220607155856-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +83.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0