<
From version < 29.9 >
edited by Xiaoling
on 2022/06/07 15:54
To version < 26.15 >
edited by Xiaoling
on 2022/06/07 15:14
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -427,6 +427,8 @@
427 427  Always 0x03
428 428  )))
429 429  
430 +
431 +
430 430  User can also send 0x14 downlink command to poll the current calibration payload.
431 431  
432 432  [[image:image-20220607145603-4.png]]
... ... @@ -561,7 +561,6 @@
561 561  
562 562  
563 563  
564 -
565 565  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
566 566  
567 567  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -677,7 +677,6 @@
677 677  
678 678  
679 679  
680 -
681 681  == 2.10 ​Firmware Change Log ==
682 682  
683 683  
... ... @@ -690,16 +690,22 @@
690 690  
691 691  
692 692  
693 -= 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
694 694  
694 +
695 +
696 +1. Configure LSPH01 via AT Command or LoRaWAN Downlink
697 +
695 695  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
696 696  
697 -* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
698 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
700 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
701 +* LoRaWAN Downlink instruction for different platforms:
699 699  
703 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
704 +
705 +
700 700  There are two kinds of commands to configure LSPH01, they are:
701 701  
702 -* (% style="color:#4f81bd" %)** General Commands**.
708 +* **General Commands**.
703 703  
704 704  These commands are to configure:
705 705  
... ... @@ -706,25 +706,25 @@
706 706  * General system settings like: uplink interval.
707 707  * LoRaWAN protocol & radio related command.
708 708  
709 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
715 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
710 710  
717 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
711 711  
712 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
713 713  
720 +* **Commands special design for LSPH01**
721 +
714 714  These commands only valid for LSPH01, as below:
715 715  
716 716  
725 +1.
726 +11. Set Transmit Interval Time
717 717  
718 -== 3.1 Set Transmit Interval Time ==
719 -
720 720  Feature: Change LoRaWAN End Node Transmit Interval.
721 721  
722 -(% style="color:#037691" %)**AT Command: AT+TDC**
730 +**AT Command: AT+TDC**
723 723  
724 -
725 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
726 -|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
727 -|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
732 +|**Command Example**|**Function**|**Response**
733 +|AT+TDC=?|Show current transmit Interval|(((
728 728  30000
729 729  
730 730  OK
... ... @@ -731,13 +731,13 @@
731 731  
732 732  the interval is 30000ms = 30s
733 733  )))
734 -|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
740 +|AT+TDC=60000|Set Transmit Interval|(((
735 735  OK
736 736  
737 737  Set transmit interval to 60000ms = 60 seconds
738 738  )))
739 739  
740 -(% style="color:#037691" %)**Downlink Command: 0x01**
746 +**Downlink Command: 0x01**
741 741  
742 742  Format: Command Code (0x01) followed by 3 bytes time value.
743 743  
... ... @@ -746,18 +746,32 @@
746 746  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
747 747  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
748 748  
755 +1.
756 +11. Set Interrupt Mode
749 749  
750 -== 3.2 Set Interrupt Mode ==
751 -
752 752  Feature, Set Interrupt mode for GPIO_EXIT.
753 753  
754 -(% style="color:#037691" %)**AT Command: AT+INTMOD**
760 +**AT Command: AT+INTMOD**
755 755  
756 -[[image:image-20220607153759-6.png]]
762 +|**Command Example**|**Function**|**Response**
763 +|AT+INTMOD=?|Show current interrupt mode|(((
764 +0
757 757  
766 +OK
758 758  
759 -(% style="color:#037691" %)**Downlink Command: 0x06**
768 +the mode is 0 = No interruption
769 +)))
770 +|AT+INTMOD=2|(((
771 +Set Transmit Interval
760 760  
773 +1. (Disable Interrupt),
774 +1. (Trigger by rising and falling edge),
775 +1. (Trigger by falling edge)
776 +1. (Trigger by rising edge)
777 +)))|OK
778 +
779 +**Downlink Command: 0x06**
780 +
761 761  Format: Command Code (0x06) followed by 3 bytes.
762 762  
763 763  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
... ... @@ -765,34 +765,37 @@
765 765  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
766 766  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
767 767  
788 +1.
789 +11. Calibrate Sensor
768 768  
769 -== 3.3 Calibrate Sensor ==
791 +Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
770 770  
771 -Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
772 772  
773 773  
795 +1.
796 +11. Get Firmware Version Info
774 774  
775 -== 3.4 Get Firmware Version Info ==
776 -
777 777  Feature: use downlink to get firmware version.
778 778  
779 -(% style="color:#037691" %)**Downlink Command: 0x26**
780 780  
781 -[[image:image-20220607154718-7.png]]
801 +**Downlink Command: 0x26**
782 782  
803 +
804 +|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
805 +|Get Firmware Version Info|Any|26|2
806 +
783 783  * Reply to the confirmation package: 26 01
784 784  * Reply to non-confirmed packet: 26 00
785 785  
786 -
787 -
788 788  Device will send an uplink after got this downlink command. With below payload:
789 789  
790 790  Configures info payload:
791 791  
792 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
793 -|=(((
794 -**Size(bytes)**
795 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
814 +|(((
815 +**Size**
816 +
817 +**(bytes)**
818 +)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
796 796  |**Value**|Software Type|(((
797 797  Frequency
798 798  
... ... @@ -802,7 +802,10 @@
802 802  
803 803  Version
804 804  )))|Sensor Type|Reserve|(((
805 -[[Message Type>>||anchor="H2.3.6MessageType"]]
828 +[[Message>>path:#Message_Type]]
829 +
830 +[[Type>>path:#Message_Type]]
831 +
806 806  Always 0x02
807 807  )))
808 808  
... ... @@ -856,10 +856,12 @@
856 856  
857 857  
858 858  
859 -= 4. Battery & How to replace =
860 860  
861 -== 4.1 Battery Type ==
862 862  
887 +
888 +1. Battery & How to replace
889 +11. Battery Type
890 +
863 863  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
864 864  
865 865  
image-20220607153237-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
image-20220607154718-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0