From version < 29.6 >
edited by Xiaoling
on 2022/06/07 15:52
To version < 26.14 >
edited by Xiaoling
on 2022/06/07 15:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -427,6 +427,8 @@
427 427  Always 0x03
428 428  )))
429 429  
430 +
431 +
430 430  User can also send 0x14 downlink command to poll the current calibration payload.
431 431  
432 432  [[image:image-20220607145603-4.png]]
... ... @@ -561,7 +561,6 @@
561 561  
562 562  
563 563  
564 -
565 565  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
566 566  
567 567  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -675,9 +675,10 @@
675 675  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
676 676  * Blink once when device transmit a packet.
677 677  
678 -== 2.10 ​Firmware Change Log ==
679 679  
680 680  
681 +== 2.10 ​Firmware Change Log ==
682 +
681 681  **Firmware download link:**
682 682  
683 683  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
... ... @@ -687,16 +687,22 @@
687 687  
688 688  
689 689  
690 -= 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
691 691  
693 +
694 +
695 +1. Configure LSPH01 via AT Command or LoRaWAN Downlink
696 +
692 692  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
693 693  
694 -* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
695 -* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
699 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
700 +* LoRaWAN Downlink instruction for different platforms:
696 696  
702 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
703 +
704 +
697 697  There are two kinds of commands to configure LSPH01, they are:
698 698  
699 -* (% style="color:#4f81bd" %)** General Commands**.
707 +* **General Commands**.
700 700  
701 701  These commands are to configure:
702 702  
... ... @@ -703,25 +703,25 @@
703 703  * General system settings like: uplink interval.
704 704  * LoRaWAN protocol & radio related command.
705 705  
706 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
714 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
707 707  
716 +[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
708 708  
709 -* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
710 710  
719 +* **Commands special design for LSPH01**
720 +
711 711  These commands only valid for LSPH01, as below:
712 712  
713 713  
724 +1.
725 +11. Set Transmit Interval Time
714 714  
715 -== 3.1 Set Transmit Interval Time ==
716 -
717 717  Feature: Change LoRaWAN End Node Transmit Interval.
718 718  
719 -(% style="color:#037691" %)**AT Command: AT+TDC**
729 +**AT Command: AT+TDC**
720 720  
721 -
722 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
723 -|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
724 -|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
731 +|**Command Example**|**Function**|**Response**
732 +|AT+TDC=?|Show current transmit Interval|(((
725 725  30000
726 726  
727 727  OK
... ... @@ -728,13 +728,13 @@
728 728  
729 729  the interval is 30000ms = 30s
730 730  )))
731 -|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
739 +|AT+TDC=60000|Set Transmit Interval|(((
732 732  OK
733 733  
734 734  Set transmit interval to 60000ms = 60 seconds
735 735  )))
736 736  
737 -(% style="color:#037691" %)**Downlink Command: 0x01**
745 +**Downlink Command: 0x01**
738 738  
739 739  Format: Command Code (0x01) followed by 3 bytes time value.
740 740  
... ... @@ -743,18 +743,32 @@
743 743  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
744 744  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
745 745  
754 +1.
755 +11. Set Interrupt Mode
746 746  
747 -== 3.2 Set Interrupt Mode ==
748 -
749 749  Feature, Set Interrupt mode for GPIO_EXIT.
750 750  
751 -(% style="color:#037691" %)**AT Command: AT+INTMOD**
759 +**AT Command: AT+INTMOD**
752 752  
753 -[[image:image-20220607153759-6.png]]
761 +|**Command Example**|**Function**|**Response**
762 +|AT+INTMOD=?|Show current interrupt mode|(((
763 +0
754 754  
765 +OK
755 755  
756 -(% style="color:#037691" %)**Downlink Command: 0x06**
767 +the mode is 0 = No interruption
768 +)))
769 +|AT+INTMOD=2|(((
770 +Set Transmit Interval
757 757  
772 +1. (Disable Interrupt),
773 +1. (Trigger by rising and falling edge),
774 +1. (Trigger by falling edge)
775 +1. (Trigger by rising edge)
776 +)))|OK
777 +
778 +**Downlink Command: 0x06**
779 +
758 758  Format: Command Code (0x06) followed by 3 bytes.
759 759  
760 760  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
... ... @@ -762,21 +762,25 @@
762 762  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
763 763  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
764 764  
787 +1.
788 +11. Calibrate Sensor
765 765  
766 -== 3.3 Calibrate Sensor ==
790 +Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
767 767  
768 -Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
769 769  
770 770  
794 +1.
795 +11. Get Firmware Version Info
771 771  
772 -== 3.4 Get Firmware Version Info ==
773 -
774 774  Feature: use downlink to get firmware version.
775 775  
776 -(% style="color:#037691" %)**Downlink Command: 0x26**
777 777  
778 -[[image:image-20220607154718-7.png]]
800 +**Downlink Command: 0x26**
779 779  
802 +
803 +|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
804 +|Get Firmware Version Info|Any|26|2
805 +
780 780  * Reply to the confirmation package: 26 01
781 781  * Reply to non-confirmed packet: 26 00
782 782  
... ... @@ -784,10 +784,11 @@
784 784  
785 785  Configures info payload:
786 786  
787 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
788 -|=(((
789 -**Size(bytes)**
790 -)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
813 +|(((
814 +**Size**
815 +
816 +**(bytes)**
817 +)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
791 791  |**Value**|Software Type|(((
792 792  Frequency
793 793  
... ... @@ -797,7 +797,10 @@
797 797  
798 798  Version
799 799  )))|Sensor Type|Reserve|(((
800 -[[Message Type>>||anchor="H2.3.6MessageType"]]
827 +[[Message>>path:#Message_Type]]
828 +
829 +[[Type>>path:#Message_Type]]
830 +
801 801  Always 0x02
802 802  )))
803 803  
image-20220607153237-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
image-20220607154718-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0