... ... @@ -435,7 +435,6 @@
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 437  
438 -
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -492,7 +492,6 @@
492 492  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
493 493  
494 494  
495 -
496 496  === 2.8.3 CN470-510 (CN470) ===
497 497  
498 498  Used in China, Default use CHE=1
... ... @@ -559,6 +559,8 @@
559 559  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
560 560  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
561 561  
560 +
561 +
562 562  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
563 563  
564 564  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -672,6 +672,8 @@
672 672  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
673 673  * Blink once when device transmit a packet.
674 674  
675 +
676 +
675 675  == 2.10 ​Firmware Change Log ==
676 676  
677 677  
... ... @@ -740,7 +740,6 @@
740 740  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
741 741  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
742 742  
743 -
744 744  == 3.2 Set Interrupt Mode ==
745 745  
746 746  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -759,7 +759,6 @@
759 759  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
760 760  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
761 761  
762 -
763 763  == 3.3 Calibrate Sensor ==
764 764  
765 765  Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -777,6 +777,7 @@
777 777  * Reply to the confirmation package: 26 01
778 778  * Reply to non-confirmed packet: 26 00
779 779  
780 +
780 780  Device will send an uplink after got this downlink command. With below payload:
781 781  
782 782  Configures info payload:
... ... @@ -848,18 +848,19 @@
848 848  
849 849  
850 850  
852 += 4. Battery & How to replace =
851 851  
854 +== 4.1 Battery Type ==
852 852  
853 -
854 -1. Battery & How to replace
855 -11. Battery Type
856 -
856 +(((
857 857  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
858 +)))
858 858  
859 -
860 +(((
860 860  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
862 +)))
861 861  
862 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
864 +[[image:1654588469844-778.png]]
863 863  
864 864  
865 865  Minimum Working Voltage for the LSPH01:
... ... @@ -867,22 +867,28 @@
867 867  LSPH01:  2.45v ~~ 3.6v
868 868  
869 869  
870 -1.
871 -11. Replace Battery
872 872  
873 +== 4.2 Replace Battery ==
874 +
875 +(((
873 873  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
877 +)))
874 874  
879 +(((
875 875  And make sure the positive and negative pins match.
881 +)))
876 876  
877 877  
878 878  
879 -1.
880 -11. Power Consumption Analyze
885 +== 4.3 Power Consumption Analyze ==
881 881  
887 +(((
882 882  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
889 +)))
883 883  
884 -
891 +(((
885 885  Instruction to use as below:
893 +)))
886 886  
887 887  
888 888  Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
... ... @@ -898,32 +898,34 @@
898 898  
899 899  And the Life expectation in difference case will be shown on the right.
900 900  
901 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
909 +[[image:1654588577573-122.png]]
902 902  
903 903  
904 904  The battery related documents as below:
905 905  
906 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]],
907 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet
908 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
909 -
910 -|(((
911 -JST-XH-2P connector
914 +* (((
915 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
912 912  )))
917 +* (((
918 +[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
919 +)))
920 +* (((
921 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
922 +)))
913 913  
914 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
924 +[[image:image-20220607155856-8.png]]
915 915  
916 916  
917 917  
918 918  1.
919 -11.
929 +11.
920 920  111. ​Battery Note
921 921  
922 922  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
923 923  
924 924  
925 -1.
926 -11.
935 +1.
936 +11.
927 927  111. ​Replace the battery
928 928  
929 929  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1654588469844-778.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +75.8 KB
Content
1654588577573-122.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +138.2 KB
Content
image-20220607155856-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +83.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0