From version < 29.2 >
edited by Xiaoling
on 2022/06/07 15:47
To version < 31.1 >
edited by Xiaoling
on 2022/06/07 15:56
>
Change comment: Uploaded new attachment "1654588577573-122.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -434,6 +434,8 @@
434 434  * Reply to the confirmation package: 14 01
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 +
438 +
437 437  == 2.8 Frequency Plans ==
438 438  
439 439  (((
... ... @@ -489,6 +489,8 @@
489 489  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
490 490  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
491 491  
494 +
495 +
492 492  === 2.8.3 CN470-510 (CN470) ===
493 493  
494 494  Used in China, Default use CHE=1
... ... @@ -556,6 +556,8 @@
556 556  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
557 557  
558 558  
563 +
564 +
559 559  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
560 560  
561 561  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -669,6 +669,9 @@
669 669  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
670 670  * Blink once when device transmit a packet.
671 671  
678 +
679 +
680 +
672 672  == 2.10 ​Firmware Change Log ==
673 673  
674 674  
... ... @@ -738,7 +738,6 @@
738 738  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
739 739  
740 740  
741 -
742 742  == 3.2 Set Interrupt Mode ==
743 743  
744 744  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -758,7 +758,6 @@
758 758  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
759 759  
760 760  
761 -
762 762  == 3.3 Calibrate Sensor ==
763 763  
764 764  Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -776,15 +776,16 @@
776 776  * Reply to the confirmation package: 26 01
777 777  * Reply to non-confirmed packet: 26 00
778 778  
786 +
787 +
779 779  Device will send an uplink after got this downlink command. With below payload:
780 780  
781 781  Configures info payload:
782 782  
783 -|(((
784 -**Size**
785 -
786 -**(bytes)**
787 -)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
792 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
793 +|=(((
794 +**Size(bytes)**
795 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
788 788  |**Value**|Software Type|(((
789 789  Frequency
790 790  
... ... @@ -794,10 +794,7 @@
794 794  
795 795  Version
796 796  )))|Sensor Type|Reserve|(((
797 -[[Message>>path:#Message_Type]]
798 -
799 -[[Type>>path:#Message_Type]]
800 -
805 +[[Message Type>>||anchor="H2.3.6MessageType"]]
801 801  Always 0x02
802 802  )))
803 803  
... ... @@ -851,18 +851,19 @@
851 851  
852 852  
853 853  
859 += 4. Battery & How to replace =
854 854  
861 +== 4.1 Battery Type ==
855 855  
856 -
857 -1. Battery & How to replace
858 -11. Battery Type
859 -
863 +(((
860 860  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
865 +)))
861 861  
862 -
867 +(((
863 863  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
869 +)))
864 864  
865 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
871 +[[image:1654588469844-778.png]]
866 866  
867 867  
868 868  Minimum Working Voltage for the LSPH01:
... ... @@ -870,22 +870,28 @@
870 870  LSPH01:  2.45v ~~ 3.6v
871 871  
872 872  
873 -1.
874 -11. Replace Battery
875 875  
880 +== 4.2 Replace Battery ==
881 +
882 +(((
876 876  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
884 +)))
877 877  
886 +(((
878 878  And make sure the positive and negative pins match.
888 +)))
879 879  
880 880  
881 881  
882 -1.
883 -11. Power Consumption Analyze
892 +== 4.3 Power Consumption Analyze ==
884 884  
894 +(((
885 885  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
896 +)))
886 886  
887 -
898 +(((
888 888  Instruction to use as below:
900 +)))
889 889  
890 890  
891 891  Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
... ... @@ -919,14 +919,14 @@
919 919  
920 920  
921 921  1.
922 -11.
934 +11.
923 923  111. ​Battery Note
924 924  
925 925  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
926 926  
927 927  
928 -1.
929 -11.
940 +1.
941 +11.
930 930  111. ​Replace the battery
931 931  
932 932  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1654588469844-778.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +75.8 KB
Content
1654588577573-122.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +138.2 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0