... ... @@ -434,6 +434,8 @@
434 434  * Reply to the confirmation package: 14 01
435 435  * Reply to non-confirmed packet: 14 00
436 436  
437 +
438 +
437 437  == 2.8 Frequency Plans ==
438 438  
439 439  (((
... ... @@ -489,6 +489,8 @@
489 489  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
490 490  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
491 491  
494 +
495 +
492 492  === 2.8.3 CN470-510 (CN470) ===
493 493  
494 494  Used in China, Default use CHE=1
... ... @@ -556,6 +556,8 @@
556 556  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
557 557  
558 558  
563 +
564 +
559 559  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
560 560  
561 561  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -669,6 +669,9 @@
669 669  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
670 670  * Blink once when device transmit a packet.
671 671  
678 +
679 +
680 +
672 672  == 2.10 ​Firmware Change Log ==
673 673  
674 674  
... ... @@ -738,7 +738,6 @@
738 738  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
739 739  
740 740  
741 -
742 742  == 3.2 Set Interrupt Mode ==
743 743  
744 744  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -757,6 +757,7 @@
757 757  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
758 758  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
759 759  
768 +
760 760  == 3.3 Calibrate Sensor ==
761 761  
762 762  Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
... ... @@ -763,30 +763,27 @@
763 763  
764 764  
765 765  
766 -
767 767  == 3.4 Get Firmware Version Info ==
768 768  
769 769  Feature: use downlink to get firmware version.
770 770  
771 -
772 772  (% style="color:#037691" %)**Downlink Command: 0x26**
773 773  
781 +[[image:image-20220607154718-7.png]]
774 774  
775 -|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
776 -|Get Firmware Version Info|Any|26|2
777 -
778 778  * Reply to the confirmation package: 26 01
779 779  * Reply to non-confirmed packet: 26 00
780 780  
786 +
787 +
781 781  Device will send an uplink after got this downlink command. With below payload:
782 782  
783 783  Configures info payload:
784 784  
785 -|(((
786 -**Size**
787 -
788 -**(bytes)**
789 -)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
792 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
793 +|=(((
794 +**Size(bytes)**
795 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
790 790  |**Value**|Software Type|(((
791 791  Frequency
792 792  
... ... @@ -796,10 +796,7 @@
796 796  
797 797  Version
798 798  )))|Sensor Type|Reserve|(((
799 -[[Message>>path:#Message_Type]]
800 -
801 -[[Type>>path:#Message_Type]]
802 -
805 +[[Message Type>>||anchor="H2.3.6MessageType"]]
803 803  Always 0x02
804 804  )))
805 805  
... ... @@ -853,18 +853,19 @@
853 853  
854 854  
855 855  
859 += 4. Battery & How to replace =
856 856  
861 +== 4.1 Battery Type ==
857 857  
858 -
859 -1. Battery & How to replace
860 -11. Battery Type
861 -
863 +(((
862 862  LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
865 +)))
863 863  
864 -
867 +(((
865 865  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
869 +)))
866 866  
867 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
871 +[[image:1654588469844-778.png]]
868 868  
869 869  
870 870  Minimum Working Voltage for the LSPH01:
... ... @@ -872,22 +872,28 @@
872 872  LSPH01:  2.45v ~~ 3.6v
873 873  
874 874  
875 -1.
876 -11. Replace Battery
877 877  
880 +== 4.2 Replace Battery ==
881 +
882 +(((
878 878  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
884 +)))
879 879  
886 +(((
880 880  And make sure the positive and negative pins match.
888 +)))
881 881  
882 882  
883 883  
884 -1.
885 -11. Power Consumption Analyze
892 +== 4.3 Power Consumption Analyze ==
886 886  
894 +(((
887 887  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
896 +)))
888 888  
889 -
898 +(((
890 890  Instruction to use as below:
900 +)))
891 891  
892 892  
893 893  Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
... ... @@ -921,14 +921,14 @@
921 921  
922 922  
923 923  1.
924 -11.
934 +11.
925 925  111. ​Battery Note
926 926  
927 927  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
928 928  
929 929  
930 -1.
931 -11.
940 +1.
941 +11.
932 932  111. ​Replace the battery
933 933  
934 934  You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
1654588469844-778.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +75.8 KB
Content
image-20220607154718-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0