... ... @@ -555,6 +555,7 @@
555 555  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
556 556  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
557 557  
558 +
558 558  === 2.8.5 AS920-923 & AS923-925 (AS923) ===
559 559  
560 560  (% style="color:blue" %)**Default Uplink channel:**
... ... @@ -736,31 +736,18 @@
736 736  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
737 737  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
738 738  
739 -1.
740 -11. Set Interrupt Mode
741 741  
742 -Feature, Set Interrupt mode for GPIO_EXIT.
743 743  
744 -**AT Command: AT+INTMOD**
742 +== 3.2 Set Interrupt Mode ==
745 745  
746 -|**Command Example**|**Function**|**Response**
747 -|AT+INTMOD=?|Show current interrupt mode|(((
748 -0
744 +Feature, Set Interrupt mode for GPIO_EXIT.
749 749  
750 -OK
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
751 751  
752 -the mode is 0 = No interruption
753 -)))
754 -|AT+INTMOD=2|(((
755 -Set Transmit Interval
748 +[[image:image-20220607153759-6.png]]
756 756  
757 -1. (Disable Interrupt),
758 -1. (Trigger by rising and falling edge),
759 -1. (Trigger by falling edge)
760 -1. (Trigger by rising edge)
761 -)))|OK
762 762  
763 -**Downlink Command: 0x06**
751 +(% style="color:#037691" %)**Downlink Command: 0x06**
764 764  
765 765  Format: Command Code (0x06) followed by 3 bytes.
766 766  
... ... @@ -769,20 +769,21 @@
769 769  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
770 770  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
771 771  
772 -1.
773 -11. Calibrate Sensor
774 774  
775 -Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
776 776  
762 +== 3.3 Calibrate Sensor ==
777 777  
764 +Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
778 778  
779 -1.
780 -11. Get Firmware Version Info
781 781  
767 +
768 +
769 +== 3.4 Get Firmware Version Info ==
770 +
782 782  Feature: use downlink to get firmware version.
783 783  
784 784  
785 -**Downlink Command: 0x26**
774 +(% style="color:#037691" %)**Downlink Command: 0x26**
786 786  
787 787  
788 788  |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved