<
From version < 27.1 >
edited by Xiaoling
on 2022/06/07 15:32
To version < 29.1 >
edited by Xiaoling
on 2022/06/07 15:47
>
Change comment: Uploaded new attachment "image-20220607154718-7.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -427,7 +427,6 @@
427 427  Always 0x03
428 428  )))
429 429  
430 -
431 431  User can also send 0x14 downlink command to poll the current calibration payload.
432 432  
433 433  [[image:image-20220607145603-4.png]]
... ... @@ -435,7 +435,6 @@
435 435  * Reply to the confirmation package: 14 01
436 436  * Reply to non-confirmed packet: 14 00
437 437  
438 -
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -491,7 +491,6 @@
491 491  * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
492 492  * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
493 493  
494 -
495 495  === 2.8.3 CN470-510 (CN470) ===
496 496  
497 497  Used in China, Default use CHE=1
... ... @@ -672,7 +672,6 @@
672 672  * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected.
673 673  * Blink once when device transmit a packet.
674 674  
675 -
676 676  == 2.10 ​Firmware Change Log ==
677 677  
678 678  
... ... @@ -692,10 +692,9 @@
692 692  * AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
693 693  * LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
694 694  
695 -
696 696  There are two kinds of commands to configure LSPH01, they are:
697 697  
698 -* **(% style="color:#4F81BD" %) General Commands**.
693 +* (% style="color:#4f81bd" %)** General Commands**.
699 699  
700 700  These commands are to configure:
701 701  
... ... @@ -705,20 +705,22 @@
705 705  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
706 706  
707 707  
708 -* **(% style="color:#4F81BD" %) Commands special design for LSPH01**
703 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
709 709  
710 710  These commands only valid for LSPH01, as below:
711 711  
712 712  
713 -1.
714 -11. Set Transmit Interval Time
715 715  
709 +== 3.1 Set Transmit Interval Time ==
710 +
716 716  Feature: Change LoRaWAN End Node Transmit Interval.
717 717  
718 -**AT Command: AT+TDC**
713 +(% style="color:#037691" %)**AT Command: AT+TDC**
719 719  
720 -|**Command Example**|**Function**|**Response**
721 -|AT+TDC=?|Show current transmit Interval|(((
715 +
716 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
717 +|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
718 +|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
722 722  30000
723 723  
724 724  OK
... ... @@ -725,13 +725,13 @@
725 725  
726 726  the interval is 30000ms = 30s
727 727  )))
728 -|AT+TDC=60000|Set Transmit Interval|(((
725 +|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
729 729  OK
730 730  
731 731  Set transmit interval to 60000ms = 60 seconds
732 732  )))
733 733  
734 -**Downlink Command: 0x01**
731 +(% style="color:#037691" %)**Downlink Command: 0x01**
735 735  
736 736  Format: Command Code (0x01) followed by 3 bytes time value.
737 737  
... ... @@ -740,31 +740,18 @@
740 740  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
741 741  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
742 742  
743 -1.
744 -11. Set Interrupt Mode
745 745  
746 -Feature, Set Interrupt mode for GPIO_EXIT.
747 747  
748 -**AT Command: AT+INTMOD**
742 +== 3.2 Set Interrupt Mode ==
749 749  
750 -|**Command Example**|**Function**|**Response**
751 -|AT+INTMOD=?|Show current interrupt mode|(((
752 -0
744 +Feature, Set Interrupt mode for GPIO_EXIT.
753 753  
754 -OK
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
755 755  
756 -the mode is 0 = No interruption
757 -)))
758 -|AT+INTMOD=2|(((
759 -Set Transmit Interval
748 +[[image:image-20220607153759-6.png]]
760 760  
761 -1. (Disable Interrupt),
762 -1. (Trigger by rising and falling edge),
763 -1. (Trigger by falling edge)
764 -1. (Trigger by rising edge)
765 -)))|OK
766 766  
767 -**Downlink Command: 0x06**
751 +(% style="color:#037691" %)**Downlink Command: 0x06**
768 768  
769 769  Format: Command Code (0x06) followed by 3 bytes.
770 770  
... ... @@ -773,20 +773,20 @@
773 773  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
774 774  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
775 775  
776 -1.
777 -11. Calibrate Sensor
778 778  
779 -Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
780 780  
762 +== 3.3 Calibrate Sensor ==
781 781  
764 +Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
782 782  
783 -1.
784 -11. Get Firmware Version Info
785 785  
767 +
768 +== 3.4 Get Firmware Version Info ==
769 +
786 786  Feature: use downlink to get firmware version.
787 787  
788 788  
789 -**Downlink Command: 0x26**
773 +(% style="color:#037691" %)**Downlink Command: 0x26**
790 790  
791 791  
792 792  |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
image-20220607154718-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0