... ... @@ -427,8 +427,6 @@
427 427  Always 0x03
428 428  )))
429 429  
430 -
431 -
432 432  User can also send 0x14 downlink command to poll the current calibration payload.
433 433  
434 434  [[image:image-20220607145603-4.png]]
... ... @@ -436,6 +436,8 @@
436 436  * Reply to the confirmation package: 14 01
437 437  * Reply to non-confirmed packet: 14 00
438 438  
437 +
438 +
439 439  == 2.8 Frequency Plans ==
440 440  
441 441  (((
... ... @@ -672,33 +672,26 @@
672 672  
673 673  == 2.10 ​Firmware Change Log ==
674 674  
675 +
675 675  **Firmware download link:**
676 676  
677 677  [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
678 678  
679 679  
680 -**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]**
681 +**Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
681 681  
682 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]]
683 683  
684 684  
685 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink =
685 685  
686 -
687 -
688 -
689 -1. Configure LSPH01 via AT Command or LoRaWAN Downlink
690 -
691 691  Use can configure LSPH01 via AT Command or LoRaWAN Downlink.
692 692  
693 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
694 -* LoRaWAN Downlink instruction for different platforms:
689 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]].
690 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]]
695 695  
696 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
697 -
698 -
699 699  There are two kinds of commands to configure LSPH01, they are:
700 700  
701 -* **General Commands**.
694 +* (% style="color:#4f81bd" %)** General Commands**.
702 702  
703 703  These commands are to configure:
704 704  
... ... @@ -705,25 +705,25 @@
705 705  * General system settings like: uplink interval.
706 706  * LoRaWAN protocol & radio related command.
707 707  
708 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
701 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
709 709  
710 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
711 711  
704 +* (% style="color:#4f81bd" %)** Commands special design for LSPH01**
712 712  
713 -* **Commands special design for LSPH01**
714 -
715 715  These commands only valid for LSPH01, as below:
716 716  
717 717  
718 -1.
719 -11. Set Transmit Interval Time
720 720  
710 +== 3.1 Set Transmit Interval Time ==
711 +
721 721  Feature: Change LoRaWAN End Node Transmit Interval.
722 722  
723 -**AT Command: AT+TDC**
714 +(% style="color:#037691" %)**AT Command: AT+TDC**
724 724  
725 -|**Command Example**|**Function**|**Response**
726 -|AT+TDC=?|Show current transmit Interval|(((
716 +
717 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:710px" %)
718 +|(% style="width:154px" %)**Command Example**|(% style="width:223px" %)**Function**|(% style="width:330px" %)**Response**
719 +|(% style="width:154px" %)AT+TDC=?|(% style="width:223px" %)Show current transmit Interval|(% style="width:330px" %)(((
727 727  30000
728 728  
729 729  OK
... ... @@ -730,13 +730,13 @@
730 730  
731 731  the interval is 30000ms = 30s
732 732  )))
733 -|AT+TDC=60000|Set Transmit Interval|(((
726 +|(% style="width:154px" %)AT+TDC=60000|(% style="width:223px" %)Set Transmit Interval|(% style="width:330px" %)(((
734 734  OK
735 735  
736 736  Set transmit interval to 60000ms = 60 seconds
737 737  )))
738 738  
739 -**Downlink Command: 0x01**
732 +(% style="color:#037691" %)**Downlink Command: 0x01**
740 740  
741 741  Format: Command Code (0x01) followed by 3 bytes time value.
742 742  
... ... @@ -745,32 +745,18 @@
745 745  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
746 746  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
747 747  
748 -1.
749 -11. Set Interrupt Mode
750 750  
742 +== 3.2 Set Interrupt Mode ==
743 +
751 751  Feature, Set Interrupt mode for GPIO_EXIT.
752 752  
753 -**AT Command: AT+INTMOD**
746 +(% style="color:#037691" %)**AT Command: AT+INTMOD**
754 754  
755 -|**Command Example**|**Function**|**Response**
756 -|AT+INTMOD=?|Show current interrupt mode|(((
757 -0
748 +[[image:image-20220607153759-6.png]]
758 758  
759 -OK
760 760  
761 -the mode is 0 = No interruption
762 -)))
763 -|AT+INTMOD=2|(((
764 -Set Transmit Interval
751 +(% style="color:#037691" %)**Downlink Command: 0x06**
765 765  
766 -1. (Disable Interrupt),
767 -1. (Trigger by rising and falling edge),
768 -1. (Trigger by falling edge)
769 -1. (Trigger by rising edge)
770 -)))|OK
771 -
772 -**Downlink Command: 0x06**
773 -
774 774  Format: Command Code (0x06) followed by 3 bytes.
775 775  
776 776  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
... ... @@ -778,25 +778,21 @@
778 778  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
779 779  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
780 780  
781 -1.
782 -11. Calibrate Sensor
783 783  
784 -Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands
761 +== 3.3 Calibrate Sensor ==
785 785  
763 +Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands
786 786  
787 787  
788 -1.
789 -11. Get Firmware Version Info
790 790  
767 +== 3.4 Get Firmware Version Info ==
768 +
791 791  Feature: use downlink to get firmware version.
792 792  
771 +(% style="color:#037691" %)**Downlink Command: 0x26**
793 793  
794 -**Downlink Command: 0x26**
773 +[[image:image-20220607154718-7.png]]
795 795  
796 -
797 -|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
798 -|Get Firmware Version Info|Any|26|2
799 -
800 800  * Reply to the confirmation package: 26 01
801 801  * Reply to non-confirmed packet: 26 00
802 802  
... ... @@ -804,11 +804,10 @@
804 804  
805 805  Configures info payload:
806 806  
807 -|(((
808 -**Size**
809 -
810 -**(bytes)**
811 -)))|**1**|**1**|**1**|**1**|**1**|**5**|**1**
782 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
783 +|=(((
784 +**Size(bytes)**
785 +)))|=**1**|=**1**|=**1**|=**1**|=**1**|=**5**|=**1**
812 812  |**Value**|Software Type|(((
813 813  Frequency
814 814  
... ... @@ -818,10 +818,7 @@
818 818  
819 819  Version
820 820  )))|Sensor Type|Reserve|(((
821 -[[Message>>path:#Message_Type]]
822 -
823 -[[Type>>path:#Message_Type]]
824 -
795 +[[Message Type>>||anchor="H2.3.6MessageType"]]
825 825  Always 0x02
826 826  )))
827 827  
image-20220607153237-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.9 KB
Content
image-20220607153759-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
image-20220607154718-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +6.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0